Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named FRAM
FRAM is a 2007 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2007, most recently in September 2024, along with 18 deficiencies — 2 with no resolution recorded — and 1 operational control.
Records from 2007 to 2024. Most recent: inspection, 28 September 2024.
- Built
- 2007
- Last inspected
- 28 September 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 18 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9370018 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LADA7
918129
Flag
NORWAY
—
Maury page id
psix-918129
Inspections, by type
…past their stated due date2
Years with a record
6 calendar years (2007–2024)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it9840 - Dead Weight, Ton
11647 - Regulatory (Subpart C or D), Gross Ton
11647 - Convention (Subpart B), Gross Ton
3818 - Convention (Subpart B), Net Ton
11647 - Regulatory (Subpart C or D), Gross Ton
11647 - Convention (Subpart B), Gross Ton
3818 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
28 September 2024
PSC A · COC-CVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8006244
20 September 2023
COC-CVE Annual · PSC A
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7794927
21 April 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7672192
19 April 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7671488
17 April 2019
Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6664561
4 October 2018
COC-CVE Quarterly · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6554617
26 April 2018
Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6399034
18 April 2018
Deficiency Check · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6393911
7 April 2018
ISPS II Exam · COC-CVE Initial · Ballast Water Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6387130
10 October 2008
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-CVE Annual
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3340320
1 November 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3091378
11 October 2007
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3077035
18 September 2007
ISPS I Exam · COC-CVE Initial
Physical examination · Activities Europe · Activity 3066420
Deficiency record · 18
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 September 2024
Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of the electrical supply from the main source of electrical power and shall be automatically connected to the emergency switchboard. PSCO observed a failure of the emergency generator to start automatically and take the emergency load required by paragraph 4 of this regulation within 45 seconds.
74SOLAS 04 II-1/42.3
17ac
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 28 September 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO identified the boat commander of lifeboat #3 was not familiar with assigned duties and was unable to effectively lower the lifeboat witht the assigned crew.
74 SOLAS 20 III/19.2.1
17ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2024
No resolution recorded
At least two independent means shall be provided for communicating orders from the navigation bridge to the position in in the machinery space or in the control room from which the engines are normally controlled: one of these shall be engine-room telegraph which provides visual indication of the orders and responses both in the machinery space and navigation bridge. The ship is not fittted with an engine-room telegraph in the machinery space of control room which indicates the speed and direction of thrust of the propellers.
74 SOLAS II-1/37
40ac
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 28 September 2024
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fittted with a cock or valve directly on the tank capable of being closed from a safe position outsided the space concerned in the event of a fire occuring in the space in which such tans are situated. HFO Service Tank #5 starboard quck closing valve did not close upon activation outside the space.
74 SOLAS 20 II-2/4.2.2.3.4
10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 September 2024
Resolved
Fire doors in amin vertical zone bulkheads, galley boundaries and stairway enclosures, remote-released sliding or power operated doors shall be equipped with an alarm that souns at least 5 s but no more than 10 s after the door is released from the central control station and before the door begins to move and continues sounding until the door is completely closed. PSCO observed FD 132 did not latch.
74 SOLAS 20 II-2/9.4.1.1.5.10
10c
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 28 September 2024
No resolution recorded
Exhasut ducts from galley ranges shall be itted with a fire damper located in the lower end of the duct which is automatically and remotely operated, and in addtiion, a remotely operated fire damper located in the upper end of the duct. Fire damper CO/1.04.61/FD, CO/1.104.63/FD, CO/1.04.64/FD did not close when activated.
74 SOLAS 14 II-2/9.7.5.2
40c
Engineering › Non-conventional Propulsion/Steering › Control Systems (Azipod)
Issued 18 April 2018
Resolved
74SOLAS('04)II-1/31.1: Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for operation and control. Ship experienced a start failure on the starboard azipod due to damaged cards in the 24V system of the converter. Ship's crew has been unable to affect repairs. 17ac
Operations/Management › Drills/Instruction › Fire
Issued 7 April 2018
Resolved
Fire drills should be planned in such a way that due consideration is given to regular practice. The muster list shall showthe duties assigned to the different members of the crew. The fire drill failed - crew could not access the space, did not set up boundaries, did not check adjacent spaces for personnel, there were people in area of drill working and in the way, there were no 1st responder actions. The second fire drill failed. The 1st responder checked the affected space, but did not check adjacent spaces. The firefighting team while on air checked each spaces as opposed to going to the affected space and fighting the fire.
Lifesaving › Launching Appliances › Davit
Issued 7 April 2018
Resolved
Starboard lifeboat could not be initially launched during inspection. Repairs were made during inspection and lowering of lifeboat was accomplished.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 April 2018
Resolved
Doors and door frames shall provide resistance to the passage of smoke and fire. Fire doors 145, cabin doors 603 and 607 do not close all the way.
Fire Fighting › Means of Escape › Stairways
Issued 7 April 2018
Resolved
Furniture in stairways shall be limited and escape routes shall be evaluated. There is portable seating in stairway landings and security equipment limiting means of escape in the stairways.
Fire Fighting › Means of Escape › Doorways
Issued 7 April 2018
Resolved
Escape doors from public spaces that are normally latched shall be fitted with quick means of release. Main dining room and crew mess are fitted with latch key toggle instead of a quick release (crash) bar.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 September 2007
Resolved
#3 Main Diesel Engine has an oil and Exhaust leak. Vessel must repair leaks to original condition.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 18 September 2007
Resolved
Lagging overhead of #2 and #3 main diesel engines is missing. Vessel must replace or repair lagging to original condition.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 18 September 2007
Resolved
Fire topping off pump is actively leaking when pump is in the off position. Vessel must replace or repair fire pump to original position.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 18 September 2007
Resolved
Sprinkler head installation on car deck and starboard boat deck is not properly located. Vessel must reposition the sprinkler head to maintain effective coverage without interfering with the small boat deployment trolley.
Lifesaving › Launching Appliances › Release Mechanism
Issued 18 September 2007
Resolved
Marine Evacuation System (MES) deployment must be conducted in presence of a U.S. Coast Guard Marine Inspector. To be corrected at next scheduled MES deployment (presently scheduled for April 2008, Los Palmos, Canary Islands).
Operations/Management › Ballast Water Managment › Ballast Retention
Issued 18 September 2007
Resolved
The vessel appears to be heavy on the port side; The starboard ballast tanks are 99% full, while the port tanks are less than 1%. The vessel still has a port side list. The vessel's class society must provide a report concerning stability of vessel. Report must state that the characteristics of the vessel are correct and safe. Contact MSD Belfast more more details [phone withheld].
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National