← All vessels
BILLIE J
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northwest District (CGD-NW) · Other hulls named BILLIE J
BILLIE J is a 2008 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2008, most recently in June 2026, along with 63 deficiencies — 6 with no resolution recorded —, 9 operational controls and 4 casualty investigations between 2010 and 2015.
Records from 2008 to 2026. Most recent: inspection, 11 June 2026.
- Built
- 2008
- Last inspected
- 11 June 2026
- Documentation
- Case Pending · documentation file of 10 September 2026
- Deficiencies
- 63 recorded · 6 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2010–2015
Identity
1209778
WDK3205
920621
Flag
UNITED STATES
367363770 (licence lapsed)
Maury page id
psix-920621
Inspections, by type
…with no type recorded4
…past their stated due date4
Years with a record
16 calendar years (2008–2026)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.9 ft × 22.5 ft × 6.5 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALL AMERICAN MARINE INC · BELLINGHAM, WA, UNITED STATES · built 2008
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationTwin Hull
Hailing portEMERYVILLE, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 8 May 2008
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Gross Ton
33 - Simplified, Net Ton
33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE5234MMSI 367363770 · expired · compulsorily equipped · granted 18 June 2008, cancelled 18 August 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 35
11 June 2026
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8405384
3 October 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8251628
5 December 2023
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7836030
4 May 2023
Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671618
12 September 2022
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7557023
5 September 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7552448
9 November 2021
Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7345657
9 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7347587
15 July 2021
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7301834
3 June 2021
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7214431
1 October 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7069669
26 May 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6963542
4 November 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6849056
12 September 2019
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6810154
12 September 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6818987
5 September 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6804581
5 September 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6819587
22 May 2018
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6420581
30 January 2018
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6345534
27 November 2017
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6313177
25 August 2017
Administrative Inspection · Excursion Permit
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6253572
23 February 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 6102475
22 March 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 5838780
5 March 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4818937
5 January 2012
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4218992
19 August 2011
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4143410
13 August 2011
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4139503
7 February 2011
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3940718
23 December 2010
Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3919697
8 March 2010
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3691752
10 February 2010
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3678059
18 March 2009
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3432247
16 January 2009
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3395521
15 May 2008
In-Service Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3242329
6 May 2008
Deadweight Survey · Construction Oversight · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3195974
Deficiency record · 63
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 16 May 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. During inspection of starboard engine room with engines running and underway, inspector’s 4 gas meter alerted for high levels of H2S and CO2. Determine cause and affect repairs so an underway operational test of starboard engine room can be completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023
No resolution recorded
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Starboard lazarette outboard jet is leaking hydraulic oil at a rate of approximately 1 drop per 10 seconds when underway. Leak is located on inboard underside.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2023
No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operation of the main propulsion machinery both ahead and astern. Port #2 engine has error at operating station (SPN 28) and is only able to be operated in backup mode. Vessel outfitted with 4 propulsion engines and may run without passengers with port #2 engine out of service.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 May 2023
No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all railings and bulwarks and their attachment to the hull structure. Starboard bulwark extending into aft swim platform on main deck has fractured welds where longitudinal frames tie into stern. Make proper repairs by next credit drydock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 16 May 2023
No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all weathertight closures above the weather deck. Main deck interior overhead has small leaks throughout that are present during rain. Make interior cabin weathertight by next credit drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at a constant marine load. Vessels STBD Aft engine raw water intake piping at the strainer had a pin hole leak and was actively leaking water into the engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2023
No resolution recorded
Individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. Vessel doesn’t appear to have check valves for each suction line to each space. Vessel shall either install check valves or provide proof of existing check valves.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 May 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: operational test of all overboard discharge and intake valves. Raw water valves in both lazarettes were seized in the open position.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner shall be prepared to conduct tests and have the vessel ready for inspections of machinery, including the following: inspection of all machinery essential to the routine operation of the vessel. Turbocharger for forward starboard engine has a u-bracket where bracket bolt is digging into turbo housing. Bolt needs suitable chafing gear or to be relocated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 May 2023
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arrestors. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Port fuel tank vent in understairs locker on aft main deck has a 1” opening at base of gooseneck not covered by a flame screen.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 May 2023
Resolved
At each inspection for certification all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Excess engine oil found throughout starboard engine room needs to be removed.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 4 May 2023
Resolved
Mariner must provide evidence of meeting the medical and physical standards in the section. Licensed mate was missing Medical Certificate. Provide certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 4 May 2023
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Vessel shall produce MIS report showing last years drug testing of employees with number of positive/negative results.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables. Provide up-to-date publications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2023
Resolved
Floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Stern ring buoy floating waterlight lanyard must be secured around the body of the ring buoy with a lanyard between 3 and 6 feet in length.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 May 2023
Resolved
An enclosed or partially enclosed space within a vessel
must be adequately ventilated in a manner suitable for
purpose of the space. Electrically powered fire dampers
must be made operational to open automatically.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 May 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (2) Three hand orange smoke distress signals. Distress signals were added during inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 January 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. The fire main pump has a leak that results in excessive spray of water in the starboard engine room.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 January 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. There are numerous leaks throughout the vessel that allows for the ingress of water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 September 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions.
The fixed bilge pumping system in the port side lazarette was inoperable and could not provide dewatering capabilities from the port lazarette bilge.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 September 2022
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge.
The pressure gauge on the fire pump was inoperable and could not display the pressure output when in operation.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 September 2022
No resolution recorded
Boundaries that separate machinery spaces from accommodation spaces, service spaces and control spaces must be lined with noncombustible insulation.
The insulation in the starboard engine room space was
damaged and needs repaired.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 12 September 2022
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request.
There was no record of drills conducted by the crew on board the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 September 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels.
There was no document on board the vessel to provide evidence of crew members being enrolled in a chemical testing program for dangerous drugs.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
The ceiling light fixture in front of the starboard restroom was not in operating condition and was not securely affixed to the ceiling.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 September 2022
Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required.
The light on the port side top deck was inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 12 September 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
In the starboard lazarette, there was an excessive accumulation of hydraulic oil in the bilge aft of the steering pump.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 September 2022
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck.
The emergency remote fuel shutoff for the starboard engine was inoperable.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 September 2022
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not undergo an annual inspection within 3 months of anniversary date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 November 2021
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. MI unable to verify bilge pump specifications due to faded/missing labeling. Vessel Rep unable to produce documentation proving UL approved pumps. Replace all bilge pumps in watertight compartments with approved pumps.
46 CFR 182.850(e)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 May 2020
Resolved
An inflatable buoyant apparatus must be serviced at a facility specifically approved by the Commandant no later than the month and year on its servicing sticker. 100-person IBA due for annual servicing on 30MAY2020. Vessel is restricted to carrying no more than 37 persons on board. 46 CFR 185.730(a)(1)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 May 2020
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release unit for EPIRB was not marked with required expiration date. Vessel is restricted to voyages less than 3NM from shore. 46 CFR 185.740(b)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 May 2020
Resolved
It is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPIRB registration expired on 30MAY2020. Vessel is restricted to voyages less than 3NM from shore. 46 CFR 184.502 [parent] & 47 CFR 80.1061(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2019
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. During expanded insepction of recent inboard, starboard Hamilton Jet steering sensor replacement and loss of steering, an unrelated electronic sensor was found taped in place at the jet drive.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2019
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line. The shutoff valve at the tank must be manually operable from outside the compartment. Stbd engine room remote shut off broke in the open position during closure test and could not shut the fuel valve.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2019
Resolved
The minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Testing fire hose indicated only 40-45 PSI at gauge (sat visual pressure/spray pattern).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2019
Resolved
The design of all exhaust systems must ensure minimum risk of injury where persons or equipment might come into contact with an exhaust pipe. Piping, the temperature of which exceeds 150 °F must be suitably insulated where necessary to prevent injuries. Exhaust laggging missing on several sections of exhaust including at two elbows which had a large "split" in the pre-formed lagging covers, and two flexible metallic exhaust unions (all missing sections from 8-12" length each).
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 16 September 2019
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crew members. Inspectors and boat crew could not find a posted hot line telephone number.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2019
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Vessel has airline style seating, all rows contain 2-3 adult PFD's, but several are not marked for storage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2019
Resolved
Electrical equipment used in a machinery space must be dripproof. Starboard engineroom aft MDE, engine mounted Cat Control Electronic box taped together (not dripproof).
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 16 September 2019
Resolved
Each electric space heater must be provided with a thermal cutout to prevent overheating. Wheelhouse space heater tested and did not appear to have thermal cutout.
09 - Working and Living Conditions › 092 - Working Conditions › Heating
Issued 16 September 2019
Resolved
Heating equipment must be suitable for marine use. Equipment designed and installed in accordance with American Boat and Yacht Council (ABYC) A-7, “Boat Heating Systems,” or with National Fire Protection Association (NFPA) 302, “Pleasure and Commercial Motor Craft,” complies with this requirement. Unknown space heater was jury rigged in port lazarette, fed by long extension cord from stbd lazarette plug outlet. Repairs or alterations that affect the safety of the vessel include replacement of electrical wiring, steering, propulsion and power supply systems and must not be made without the approval of the cognizant OCMI.The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] lazarette had space heater jury rigged in bulkhead, with 50' extension cord to stbd lazarette plug outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 September 2019
Resolved
Propulsion machinery of an unusual type for small passenger vessels must be given separate consideration and is subject to such requirements as determined necessary by the cognizant OCMI. The requirements for machinery propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) and subchapter J (Electrical Engineering) of this chapter. Recent log entry showed wing station control failed and needed to be trasnferred back to wheelhouse helm. Provide details on the steering system visible and audible alarm system for this vessel and show proper operation of these systems.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2019
Resolved
Vessel o/o issued CG-835 September 5, 2019, not to carry passengers due to not having the required annual inspection IAW 46 CFR § 176.500(b)(1). (See Admin Activity 6804581)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 September 2019
Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not completed required Annual Inspection. 46 CFR 176.500(b)(1)
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 7 June 2018
Resolved
On a vessel of not more than 65 feet in length and carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The fire pump did not provide adequate pressure, visually, which could not be verified due to an inoperable pressure gauge at the pump outlet. Pressure witnessed was not able to reach all areas of the vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2018
Resolved
Every vessel subject to Part III of Title II of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 once every five years. The vessel did not have a Radiotelephony certificate onboard.
47 CFR 80.903
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2018
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner asto avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cableinstallations, and not used as a means of support. Portions of wiring in the engine rooms and forward compartments were supported by plastic zip ties.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 7 June 2018
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated
unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling
garbage follows the plan. Vessel does not have a waste management plan onboard.
33 CFR 151.57
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 19 August 2011
Resolved
Vessel has fixed seating for 70 pax & allows up to 2 wheelchairs per trip provided the total pax count is not exceeded. When wheelchair seating is utilized, it must adhere to the requirements in 46 CFR 177.820 to include aisle width, seating distance, & be properly secured to a deck or bulkhead. Provide means of securing wheelchair seating & update the ops manual to address this requirement.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 17 February 2011
Resolved
Marine Employer failed to ensure at least 50% of covered crewmembers were selected for random drug testing during calendar year 2010. Marine Employer must ensure 50% of covered crewmembers is selected for random drug testing during calendar year 2011. Marine Employer conducted a periodic drug test on all crewmembers and has all crewmembers enrolled in Drug Consortium (APCA).
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 8 March 2010
Resolved
During testing the port Fire Boy was discharged into the port pontoon. An 835 was issued with specific instructions for operation until the pre-engineered system is replaced by 12 Mar 10. SEE scanned CG-835 in documents.
Lifesaving › Lifebuoys › Not on Board
Issued 15 May 2008
Resolved
Replace one lifebuoy which was stolen off of the vessel on 22 Jun 08.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2008
Resolved
The waterlight needs to be clipped to the lifebuoy, not permanently tied.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 May 2008
Resolved
Lable upper deck maximum capacity to 50 passengers.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Valve
Issued 15 May 2008
Resolved
Fix small leak on the diesel generator.
Documentation › Certificates/Documents › Stability Letter
Issued 15 May 2008
Resolved
Post MSC approved stability letter
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 May 2008
Resolved
Post lifejacket donning placard.
Documentation › Certificates/Documents › Stability Letter
Issued 6 May 2008
Resolved
Provided an approved stability letter from MSC and properly display onboard the vsl.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 May 2008
Resolved
Vessels owner/operator needs to contact local OCMI for operations of the vsl and conduct drills.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 6 May 2008
Resolved
Provide proper operation of the fire pump.
Engineering › Non-conventional Propulsion/Steering › Impeller (jet)
Issued 6 May 2008
Resolved
Need to provide approved plans from MSC for the Hamilton Jet system, reference ltr E2-0800186 item 3.
Engineering › Fuel Oil Service System › Piping
Issued 6 May 2008
Resolved
Provide approved plans from MSC for fuel system drawing, reference ltr E1-081155
Casualty record · 4
23 December 2010Routine · role: Involved in a Marine Casualty · activity 3919697
13 August 2011Routine · role: Involved in a Marine Casualty · 1 injured · activity 4139503
13 October 2012Routine · role: Involved in a Marine Casualty · activity 4465500
1 April 2015Routine · role: Involved in a Marine Casualty · 1 injured · activity 5107643
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
RIVER GORGE EXPLORER (2010–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.