Records from 1985 to 1990. Most recent: inspection, 31 January 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
31 January 1990
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 919977
14 October 1987
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1015370
24 September 1987
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1010499
21 September 1987
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1008108
23 July 1987
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1033274
11 June 1987
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1004262
23 May 1986
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 985045
1 May 1986
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1302401
26 March 1986
Credit Drydock
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 993586
6 September 1985
Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1296362
3 May 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1287816
10 April 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 978388
22 March 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 982772
Engineering
Issued 21 September 1987
Resolved
REPLACE FLEXIBLE FUEL SUPPLY AND RETURN HOSES WITH COPPER PIPE TO COMPLY WITH 46 CFR 182.20-40.
Condition: Unknown
Due 21 September 1987
Resolved 21 September 1987
Accommodation/Occupational Safety
Issued 11 June 1987
Resolved
OBTAIN AND PLACE ON BOARD A BLACK ANCHOR BALL.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Fire Fighting
Issued 11 June 1987
Resolved
PROVIDE SERVICING REPORT FOR THE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Navigation
Issued 11 June 1987
Resolved
PROVIDE UP-TO-DATE CHARTS FOR LAKE MICHIGAN, LIGHT LIST, COAST PILOT AND SUBCHAPTER T REGULATIONS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
PROVIDE DOCUMENTATION THAT THE MAIN FUEL WALL THICKNESS IS 12 MSG OR BETTER AND THE ENGINEROOM FUEL TANKS ARE 14 MSG OR BETTER.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 11 June 1987
Resolved
PERMANENTLY SECURE ENGINEROOM PORT LIGHTS OR PROVIDE STEEL DEAD COVER.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1987
Resolved
STENCIL VESSEL NAME ON THE LIFEFLOAT, WATERLIGHT, PADDLES AND NEW LIFE JACKETS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1987
Resolved
PROVIDE 26 ADDITIONAL ADULT PFD(S) AND 2 CHILD PFD(S). VESSEL IS LIMITED TO A TOTAL OF 24 PERSONS UNTIL ITEMS ARE ACQUIRED AND PLACED ON BOARD THE VESSEL.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
PROVIDE GROUND STRAPS ON FUEL TANK VENT BILGES IN WAY OF THE RUBBER HOSE COUPLINGS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
CLEAN ALL OIL FROM BILGES.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Accommodation/Occupational Safety
Issued 11 June 1987
Resolved
REMOVE ALL BAD BATTERIES, CABLES, OIL CANS, BOXES AND OTHER NON- ESSENTIAL ITEMS FROM ENGINEROOM.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
REPLACE ALL HOSES ON THE BILGE PUMPS AND SINKS WITH METALLIC OR RIGID NON- METALLIC 40 GAGE PVC PIPE FITTED WITH CHECK OR GATE VALVES AT THE HULL CONNECTION.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Fire Fighting
Issued 11 June 1987
Resolved
REMOUNT B-II EXTINGUISHERS AT THE ENGINEROOM ENTRANCE.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Electrical
Issued 11 June 1987
Resolved
PROVIDE BATTERY BOXES WITH ACID RESISTANT LININGS FOR ALL BATTERIES. AS PER 46 CFR 183.05-20(D), BATTERIES SHOULD BE STORED AS HIGH ABOVE THE BILGEAS POSSIBLE.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 11 June 1987
Resolved
MAKE PERMANENT REPAIRS TO ALL PORT LIGHTS EXCEPT IN THE ENGINEROOM BY IN- STALLING 1/4" GLASS AND MAKE THEM PERMANENTLY SECURED.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Accommodation/Occupational Safety
Issued 11 June 1987
Resolved
PROVIDE CHAIN LINK FENCING, WIRE MESH OR EQUIVALENT ON THE MAIN DECK RAILS TO COMPLY WITH 46 CFR 177.35.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
PROVIDE PROTECTIVE GUARDS AROUND THE ALTERNATOR BELT DRIVE ON THE PORT MAIN ENGINE AND ANY OTHER EXPOSED MOVING PARTS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Accommodation/Occupational Safety
Issued 11 June 1987
Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD CABIN SIDE STORM RAIL BY REPLACING OR RESECURING MOUNTING BRACKET SCREWS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Lifesaving
Issued 11 June 1987
Resolved
PROVIDE WATER LIGHT FOR RING BOUY WHICH COMPLIES WITH 46 CFR 161.010.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Accommodation/Occupational Safety
Issued 11 June 1987
Resolved
MAKE PERMANENT REPAIRS TO MAIN DECK RAILS AT THE BOW BY REPLACING OR RESECURING MOUNTING BRACKET SCREWS.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Accommodation/Occupational Safety
Issued 11 June 1987
Resolved
MARK MAIN STATEROOM ESCAPE HATCH AS PER 46 CFR 185.30-15.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Engineering
Issued 11 June 1987
Resolved
REPLACE FLEXIBLE FUEL SUPPLY AND RETURN HOSES WITH COPPER PIPE TO COMPLY WITH 46 CFR 182.20-40.
Condition: Unknown
Due 11 June 1987
Resolved 11 June 1987
Construction/Loadline
Issued 10 April 1985
Resolved
PROVIDE PLANS OF THE MIDSHIP SECTION, OUTBD PROFILE, INBD PROFILE, ARRANGE-MENT OF DECKS, MACHINERY INSTALLATIONS, FUEL TANKS, PIPING SYSTEMS AND HULLPENETRATIONS AND SHELL CONNECTIONS IN ACCORDANCE WITH 46 CFR 177.05-01(A).
Condition: Unknown
Due 16 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 10 April 1985
Resolved
MAKE PERMANENT REPAIRS TO ALL PORT LIGHTS LOCATED BELOW THE WEATHER DECK TO MAKE THEM PERMANENTLY CLOSED OR INSTALL HINGED DEAD COVERS IN ACCORDANCEWITH 46CFR 171.119 (A).
Condition: Unknown
Due 10 April 1985
Resolved 10 April 1985