MAURY USCG vessel records Sign in
← All vessels

CAPT. L.A. TICE

CAPT. L.A. TICE is a 1967 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1986, most recently in June 2006, along with 49 deficiencies — 1 with no resolution recorded —.

Records from 1986 to 2006. Most recent: inspection, 5 June 2006.

Built
1967
Last inspected
5 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCM2078
Flag
UNITED STATES
—
Maury page id
psix-92149

Inspections, by type

…with no type recorded8
Years with a record 18 calendar years (1986–2006)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Net Ton
56 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCM2078MMSI not assigned · expired · voluntarily equipped · granted 23 August 1994, cancelled 23 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 41

5 June 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2673333
16 April 2004 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2045512
4 November 2003 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2003750
11 July 2003 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1842857
6 May 2002 Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1613581
4 June 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1066851
25 May 2000 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1050762
19 April 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 818236
13 September 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 148262
17 June 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1105658
5 June 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 25364
7 May 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1125761
4 May 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 800381
27 March 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789898
25 March 1998 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 787174
24 March 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 787787
23 March 1998 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 788153
23 June 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112714
22 April 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1096436
16 April 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1081893
22 February 1996 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1433019
21 September 1993 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1148770
2 November 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 939573
30 October 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934375
16 September 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1238715
25 August 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 230718
19 August 1992 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 945946
14 August 1991 Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1258553
19 March 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 919960
7 February 1991 Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 901368
10 October 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1241627
13 September 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 926969
12 September 1990 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 926792
23 August 1989 Deficiency Check · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1037125
9 August 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1198034
24 August 1988 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1347790
3 May 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1345459
26 January 1988 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1014654
7 October 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1016736
25 August 1987 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1337954
7 August 1986 Credit Drydock · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1308074

Deficiency record · 49

Documentation
Issued 4 November 2003 No resolution recorded
Vessel did not recieve topside inspection for 2003. Vessel is restricted from carrying passengers until a satisfactory exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Engineering › Bilge Water Management System
Issued 6 May 2002 Resolved
Repair/Provide High Water Bilge Alarm in Lazarette. LEGACY COMPONENT DESC: Interface Detector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2002
Resolved 17 May 2002
Operations/Management › Drug and Alcohol Testing
Issued 6 May 2002 Resolved
Provide list of all employees enrolled in Drug/Alcohol constortium. LEGACY COMPONENT DESC: Employee Coverage
Due 17 May 2002
Resolved 17 May 2002
Navigation › Piloting/Steering
Issued 6 May 2002 Resolved
Provide current copy of Navigational Rules of the Road. LEGACY COMPONENT DESC: Inland Navigation Rules
Due 17 May 2002
Resolved 17 May 2002
Lifesaving › Buoyant Apparatus
Issued 6 May 2002 Resolved
Provide proper operation of life float water light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2002
Resolved 17 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 6 May 2002 Resolved
Provide/Post Emergency Instruction List.
Due 17 May 2002
Resolved 17 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 May 2002 Resolved
Re-new eyewash in First Aid Kit.
Due 17 May 2002
Resolved 17 May 2002
Construction/Loadline › Structures
Issued 6 May 2002 Resolved
Repair window on brigde, port side, aft.
Due 17 May 2002
Resolved 17 May 2002
Lifesaving
Issued 4 June 2001 Resolved
PROVIDE PROOF OF EPRIB REGISTRATION AND HYDROSTATIC RELEASE, VESSEL LIMITEDTO NO GREATER THAN THREE MILES FROM SHORE.
Condition: Unknown
Due 15 June 2001
Resolved 8 June 2001
Navigation
Issued 25 March 1998 Resolved
COTTERPIN/DOUBLE-NUT STEERING GEAR RAM/CYLINDER CONNECTIONS.
Condition: Unknown
Due 27 March 1998
Resolved 3 April 1998
Documentation
Issued 25 March 1998 Resolved
PROVIDE DOCUMENTATION OF USER FEE PAYMENT.
Condition: Unknown
Due 25 March 1998
Resolved 25 March 1998
Lifesaving
Issued 25 March 1998 Resolved
PLACE RETRO TAPE ON NEW RING BUOYS AND PROVIDE CLIP ON FLOAT LIGHT.
Condition: Unknown
Due 27 March 1998
Resolved 3 April 1998
Navigation
Issued 25 March 1998 Resolved
PROVE OPERATION OF NEWLY INSTALLED SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 27 March 1998
Resolved 3 April 1998
Construction/Loadline
Issued 25 March 1998 Resolved
RENEW DECK HATCH GASKETS.
Condition: Unknown
Due 27 March 1998
Resolved 3 April 1998
Lifesaving
Issued 22 February 1996 Resolved
PROVIDE 12 ADULT AND 8 CHILDREN TYPE 1 LIFE PRESERVERS.
Condition: Unknown
Due 15 March 1996
Resolved 24 April 1996
Construction/Loadline
Issued 19 August 1992 Resolved
MAKE WATERIGHT ALL MAIN DECK HATCHES. (TOTAL 3)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
REPLACE LIGHT COVERS AS NEEDED IN PASSENGER SPACES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
REPLACE POWER DISTRUBUTION PANEL COVER (AC) IN THE WHEEL HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
CORRECT OPERATION OF THE OVERSPEED DEVICE ON THE GENERATOR. PROVE PROPER_x001C_ OPERATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Accommodation/Occupational Safety
Issued 19 August 1992 Resolved
STENCIL SEWAGE OVERBOARD VALVE AREA, DO NOT OPEN WHILE IN U.S. WATERS.._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Engineering
Issued 19 August 1992 Resolved
DOUBLE CLAMP A WATER HOSES IN THE MACHINERY SPACES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
REPLACE COVER AND INSTALL BLANKS IN GENERATOR DISTRUBUTION PANEL LOCATED_x001C_ IN MACHINERY SPACE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
SECURE GENERATOR FREQUENCY METER BOX FROM HORIZONTAL MOVEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
INSTALL DRIP SHIELDS OVER BATTERY CHARGERS AND DISTRUBUTION BOXES IN _x001C_ MACHINERY SPACES.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Electrical
Issued 19 August 1992 Resolved
REPAIR LIGHT IN MACHINERY SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Navigation
Issued 19 August 1992 Resolved
REPAIR, REPLACE OR REMOVE THE HF/SSB RADIO LOCATED ON THE BRIDGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Construction/Loadline
Issued 19 August 1992 Resolved
MAKE WATERIGHT THE WEAPING WELD AROUND THE HAWSE PIPE PENETRATIONS THRU THEFOREPEAK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Construction/Loadline
Issued 19 August 1992 Resolved
REPAIR COMBING ON THE HATCH LEADING BELOW MAIN DECK TO THE PASSENGER AREA._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Accommodation/Occupational Safety
Issued 13 September 1990 Resolved
INSTALL AND PROVE PROPER OPERATION OF A CG CERTIFIED TYPE II OR TYPE III MARINE SANITATION DEVICE. REMOVE THE THE NEWLY INSTALLED TYPE I MSD FROM THE VESSEL. THE VESSEL'S MSD OVERBOARD DISCHARGE VALVE SHALL BE SECURED/ CLOSED AND LOCKED WHILE THE VESSEL IS OPERATING WITHIN 3 MILES OF SHORE.
Condition: Unknown
Due 13 September 1990
Resolved 13 September 1990
Construction/Loadline
Issued 12 September 1990 Resolved
REPLACE GASKETS ON ENGINEROOM AND CABIN HATCHES.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Lifesaving
Issued 12 September 1990 Resolved
ATTACH LINE FOR FLOAT LIGHT TO LIFE RING BUOY.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Navigation
Issued 12 September 1990 Resolved
PROVE OPERATION OF SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Lifesaving
Issued 12 September 1990 Resolved
STOW 50% OF THE VESSEL'S CHILDREN'S PFD'S ON DECK AND REMARK PFD STORAGE LOCKERS.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Accommodation/Occupational Safety
Issued 12 September 1990 Resolved
REPAIR WASH BASIN IN MEN'S HEAD.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
INSTALL FLEX HOSE IN PORT MDE RAW WATER DISCHARGE PIPING.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Engineering
Issued 12 September 1990 Resolved
REPLACE V-BELT GUARD ON FRESH WATER PUMP
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Fire Fighting
Issued 12 September 1990 Resolved
PROVIDE HAND PORTABLE FIRE PUMP WITH SUCTION AND DISCHARGE HOSES.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Documentation
Issued 12 September 1990 Resolved
PREPARE MARPOL ANNEX V WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 12 September 1990
Resolved 12 September 1990
Accommodation/Occupational Safety
Issued 23 August 1989 Resolved
PROVE PROPER OPERATION OF THE VESSEL'S INBOARD TOILET/MSD.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Engineering
Issued 23 August 1989 Resolved
PROVIDE PIPE PLUGS, AND SAFETY SHIELDS ON BOTH DIESEL ENGINE RAYCO FUEL OILFILTERS.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Lifesaving
Issued 25 August 1987 Resolved
PROVIDE A LADDER, LEADING UP TO THE LIFE RAFTS. (PASSENGER ACCESS).
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987 Resolved
PROVIDE A VALID COMMUNICATIONS ACT SAFETY CERTIFICATE AND A COPY OF FCC RULES.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987 Resolved
PROVIDE A SIGN IN THE PASSENGER AREA, (LOWER) 'EMERGENCY ESCAPE' ABOVE LADDER, (FORWORD).
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987 Resolved
PROVIDE BLACK SCREENS ON BOTH THE PORT AND STBD RUNNING LIGHTS.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987 Resolved
PROVIDE BATTERY BOX COVERS FOR BOTH THE MAIN DIESEL ENGINE AND GENERATOR STARTING BATTERY BOXES.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987 Resolved
PROVIDE A NEW FIRE HOSE, ON THE MAIN DECK FIRE STATION.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987 Resolved
POST A VALID MARINE OPERATOR PERMIT.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Construction/Loadline
Issued 25 August 1987 Resolved
PROVIDE A WATERTIGHT GASKET FOR THE DOOR TO THE LOWER PASSENGER AREA.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987 Resolved
REPAIR/ADJUST STEERING GEAR CABLE ON THE STBD SIDE, CABLE AND CHAIN ARE HANGING UP DURING STEERING OPERATIONS.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.