MAURY USCG vessel records Sign in
← All vessels

ER SEOUL

ER SEOUL is a 2000 freight ship. The Coast Guard has recorded 25 inspections since 2007, most recently in November 2019, along with 5 deficiencies and 3 operational controls.

Records from 2007 to 2019. Most recent: inspection, 14 November 2019.

Built
2000
Last inspected
14 November 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208021 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-9221

Inspections, by type

…with no type recorded6
Years with a record 10 calendar years (2007–2019)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it66289 - Convention (Subpart B), Gross Ton
67737 - Dead Weight, Metric Ton
92439 - Displacement, Metric Ton
33235 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

14 November 2019 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6855580
24 April 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6669162
24 April 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6669274
19 February 2019 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6628303
5 September 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6533311
30 August 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6525216
28 August 2018 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6525244
19 July 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6484257
24 May 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6422603
22 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6420532
5 December 2017 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6318295
27 April 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6133518
29 March 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5842549
13 October 2015 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5741828
6 August 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4945954
17 March 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4817251
21 February 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4248333
21 April 2009 MARPOL Annex V Examination · Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3457234
16 May 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3202435
19 November 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3101272
18 July 2007 Attraction Vessel Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2999916
18 July 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3004949
27 April 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2916929
26 April 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2917236
18 April 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2910264

Deficiency record · 5

Engineering › Fuel Oil Service System › Valve, Control
Issued 21 April 2009 Resolved
Emergency Fuel Oil stop for the Emergency Generator is rusted, broken and unable to cut off the fuel supply to the generator. Fuel Stop cable and handle must be replaced to the satisfaction of the attending classification surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 April 2009
Resolution: Received report from Classification surveyor attesting to the replacement of Emergency Generator fuel supply cut-off cable and handle prior to departure. [name withheld]
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 21 April 2009 Resolved
The Oily Separator’s pipe to the suction pump has a temporary repair patch. This pipe must be repaired to the satisfaction of the attending classification surveyor.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 June 2009
Resolution: Received fax report from class attesting to the satisfactory repair of the suction pipe in way of the oily water separator.
Engineering › Compressed Air System (control) › Piping
Issued 18 July 2007 Resolved
Vessels dryer for the control air sys is burned out. 15a
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 August 2007
Resolution: RECIEVED FAX FROM CLASS STATING DEF HAS BEEN RESOLVED
Engineering › Compressed Air System (control) › Compressor
Issued 18 July 2007 Resolved
Vessels control air sys is producing excessive amounts of moisture and oily residue. 17b
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2007
Resolution: Received class survey stating control air sys was cleaned and inspected.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 July 2007 Resolved
Maintenance planning sys does not clearly detail machinery servicing procedures or required timelines; to complex and laborious for effactive use. 70a
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 July 2007
Resolution: MAINTENANCE PLANNING SYSTEM HAS BEEN INPECTED BY CLASS AND BEEN FOUND TO BE SATISFACTORY

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.