← All vessels
MEDITERRANEAN
Offshore Supply Vessel · Offshore class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named MEDITERRANEAN
MEDITERRANEAN is a 2007 offshore supply vessel. The Coast Guard has recorded 23 inspections since 2007, most recently in February 2025, along with 42 deficiencies, 1 operational control and 2 casualty investigations between 2011 and 2019.
Records from 2007 to 2025. Most recent: inspection, 25 February 2025.
- Built
- 2007
- Last inspected
- 25 February 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 42 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2011–2019
Identity
1207578
9490947 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDK5600
922510
Flag
UNITED STATES
367327360
Maury page id
psix-922510
Inspections, by type
…with no type recorded2
Years with a record
12 calendar years (2007–2025)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)150.4 ft × 36.0 ft × 11.5 ft
Registered tonnagegross 83 / net 56
ITC dimensions (L × B × D)150.4 ft × 36.0 ft × 11.5 ft
ITC tonnagegross 499 / net 193
BuilderC & C BOAT WORKS LLC · BELLE CHASSE, LA, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Net Ton
193 - Convention (Subpart B), Net Ton
83 - Regulatory (Subpart C or D), Gross Ton
499 - Convention (Subpart B), Gross Ton
488 - Dead Weight, Gross Ton
456 - Displacement, Gross Ton
193 - Convention (Subpart B), Net Ton
83 - Regulatory (Subpart C or D), Gross Ton
499 - Convention (Subpart B), Gross Ton
488 - Dead Weight, Gross Ton
456 - Displacement, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK5600MMSI 367327360 · active · compulsorily equipped · granted 15 November 2018, expires 15 November 2028
WDE2612MMSI 367327360 · expired · compulsorily equipped · granted 18 December 2007, cancelled 17 February 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 23
25 February 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8085206
12 February 2025
Drydock Exam · Examination of Repairs · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8077808
12 March 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7877641
28 November 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7600775
22 November 2022
Drydock Exam · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7598048
7 February 2022
Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7391701
2 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7133854
10 February 2020
Damage Survey · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6906371
6 February 2020
Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6903939
4 June 2019
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6703919
3 June 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6751254
29 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6617338
25 October 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6294690
18 October 2017
Cargo Tank Internal · Administrative Inspection · Drydock Exam · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Activities Europe · Activity 6289970
4 January 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6065305
3 February 2016
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5803882
20 October 2014
MTSA Verification · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5006214
16 October 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5006564
10 October 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5002141
7 October 2014
Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4998362
6 January 2010
DAPI Audit · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3661886
5 May 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3467717
17 December 2007
Cargo Tank Internal · Construction Oversight · Internal Structural Exam · Hull Examination · MTSA Verification · Initial Certification · Administrative Inspection · Plan Review (Other than "T") · Deadweight Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3117081
Deficiency record · 42
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 February 2025
Resolved
An OSV may carry hazardous material in portable tanks, in compliance with part 64 and subpart 98.30. Vessel's AFFF inductor not functioning properly as the inductor filled the bucket when the connected fire hose was under pressure. 705 - Vessel prohibited from carrying portable tanks.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 25 February 2025
Resolved
Each Radio or GMDSS component shall have an final emergency power source. Backup battery for the distress radio was not functional and required to be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2025
Resolved
Lifesaving appliances and arrangements shall be in satisfactory condition and remain fit for service. Vessel had one Lifebuoy with a rotten plug that was not watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 February 2025
Resolved
Each lifejacket must be marked in block capital letters with the name of the OSV. ER Lifejacket had the wrong (Energy XXI) name stenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 March 2024
Resolved
Each lifefloat must be capable of float free and be arranged as follows: a painter line that encircles the body of the lifefloat and will not slip off; the strength of the float-free link and the strength of the groups single painter must be appropriate for the combined capacity of the group of lifefloats. Vessel painter line for both port and starboard were attached to a grab line and the port and starboard weaklink was rated for 21 or more capacity when the total capacity for each stack was 20 persons(two ten-man lifefloats).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 March 2024
Resolved
All access openings in bulkheads must be of equivalent strength to the unpierced bulkhead and and weathertight when closed. Vessel had three WTDs that required adjustment as airflow was felt and/or dogs to secure the door were loose (Bow thruster, accommodation to ER, and ER to escape hatch).
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 March 2024
Resolved
Each vessel subject to load line requirements shall carry on board a valid certificate attesting to compliance. Vessel went beyond 3 month renewal window (07FEB2024) and was operating the vessel 08FEB2024 and after.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 November 2022
Resolved
Each vessel must be equipped with one self-priming power-driven fire pump capable of delivering a single stream of at least 50 psi. When running the fire pump, gauge only reached 40 psi. 46 CFR 132.120(a)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 22 November 2022
Resolved
Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. There were wiring through holes leading into the emergency escape space. Plug holes. - 46 CFR 127.220(a)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 February 2021
Resolved
The EPRIB registration had the incorrect call sign for the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 2 February 2021
Resolved
The emergency steering station rudder angle indicator was off by approximately 15 degrees.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 February 2021
Resolved
The retroreflective tape needed to be replaced, dunnage needed to be added, and the securing arrangement needed to be fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 February 2021
Resolved
The port side relief device did not have a date and the starboard side relief valve for the pressure vessels was last tested/inspected in 2013.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 6 February 2020
Resolved
Vessel must have an oil pollution placard in machinery space or near the bilge pump/piping. Ensure placard is installed properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 February 2020
Resolved
Each electrical installation must meet IEEE. The switchboard and distribution panels indicator lights were inop. Replace bulbs as necessary.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 February 2020
Resolved
Each non metallic flexible hose on machinery must be IAW SAEJ1942. The hose was bulging and chaffed rendering it unserviceable. Install new fuel hose that meets the above specs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 February 2020
Resolved
Means of securing and watertight integrity must be maintained. The port escape hatch was not watertight. Ensure hatch is adjusted properly to ensure water tightness.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2020
Resolved
Each life jacket must have a life jacket light attached with proper approval number and each life jacket must be labeled with the vessels name on it. The life jacket light was expired and the other life jacket had a different named vessel marked on it. Replace light and label other jacket with current vessel name.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2020
Resolved
Each OSV must be hauled out at the appropriate intervals IAW COI. The vessel is 4 months past the due date for dry dock/ISE. Schedule and complete dry dock prior to departure.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 4 June 2019
Resolved
Provide repairs to STBD shell plating on the 01 deck at the next drydock.
Navigation › Piloting/Steering › Marine Charts
Issued 30 October 2017
Resolved
Marine charts for areas operated not onboard. The only charts on hand were block charts.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear/Clutch Starter (electric)
Issued 30 October 2017
Resolved
#2 port generator prime mover would not start, problem isolated to the starter, 3 starters were installed during inspection with negative results.
Fire Fighting › Fire Hoses › Connections
Issued 30 October 2017
Resolved
01 of the 05 fire hoses onboard were not ofthe approved type.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 30 October 2017
Resolved
Knife switch box for A/C 01 level exterior has a broked door.
Communications › Public Address System › Loudspeaker
Issued 30 October 2017
Resolved
Found a J-Box at the anchor windlass missing plugs. Found that the J-Box was for a missing P/A Speaker.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 October 2017
Resolved
Vessel outfitted with a Facsimile Receiver, which would not power on. A service representative attended the vessel, the power issued corrected, but could not prove that it was receiving, NAVTEX on hand.
Engineering › Pressure Vessel › Relief Valve
Issued 3 February 2016
Resolved
STBD pressure vessel relieve valve fail to actuate before MAWP. Replace/prove proper operation of PRV.
Engineering › Pressure Vessel › Pressure Gauge
Issued 3 February 2016
Resolved
Guages do not show sufficient psi range. Replace, demonstrate proper operation.
Communications › Radio Communications › EPIRB
Issued 3 February 2016
Resolved
hydrostatic release on EPIRB is expired. Replace hydro.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 February 2016
Resolved
Packing leaking excessivelly on both shafts. Make repairs.
Lifesaving › Lifefloat › Lifeline
Issued 3 February 2016
Resolved
weak link not of appropriate size. Install appropriate weak links on lifefloats.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 October 2014
Resolved
Properly secure battery boxes.
Lifesaving › Lifefloat › Float Free
Issued 20 October 2014
Resolved
Properly rig painter to provide for float free operation. Additionally, provide sufficient line between floats to allow one to reach the water prior to the other leaving the cradle.
Electrical › Electric Supply System (service) › Reverse Current Protection
Issued 20 October 2014
Resolved
Prove proper operation of reverse power relay. Gensets capable of operating in parallel, but reverse power relay inoperable.
Stability › Watertight Integrity › General
Issued 20 October 2014
Resolved
Make A/C drain penetration at forward engineering bulkhead watertight.
Lifesaving › Lifebuoys › Serviceable
Issued 20 October 2014
Resolved
Replace two (02) life rings due to water ingress. Identified rings are manufactured by DATREX. Water ingress is incredibly common with the DATREX brand life rings.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 10 October 2014
Resolved
Demonstrate proper operation of e-stops for main propulsion engines at pilothouse.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 October 2014
Resolved
Provide audible/visual alarms at bridge for high bilge level in watertight compartments
Engineering › Steering Gear System › Ram
Issued 10 October 2014
Resolved
Demonstrate operation of main/auxillary steering systems
Stability › Watertight Integrity › General
Issued 10 October 2014
Resolved
Adjust all quick-acting watertight doors; make watertight
Communications › Public Address System › Broadcast Location
Issued 10 October 2014
Resolved
Demonstrate operation of PA system on backup power supply
Communications › Alarms/Indicators › Fire Alarm
Issued 10 October 2014
Resolved
Install smoke detection alarms in accommodation spaces, including galley/bridge
Casualty record · 2
12 April 2011Routine · role: Involved in a Marine Casualty · activity 3985795
3 June 2019Routine · role: Involved in a Marine Casualty · activity 6751254
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.