MAURY USCG vessel records
← All vessels

ALHANI

ALHANI is a 2007 tank ship. The Coast Guard has recorded 8 inspections since 2018, most recently in October 2021, along with 2 deficiencies.

Records from 2018 to 2021. Most recent: inspection, 31 October 2021.

Built
2007
Last inspected
31 October 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9331153
923892
Flag
LIBYA
Maury page id
psix-923892

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 4 calendar years (2018–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it35445 - Convention (Subpart B), Net Ton
114795 - Dead Weight, Metric Ton
133054 - Displacement, Metric Ton
61348 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

31 October 2021 PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7338151
1 December 2020 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7104611
11 November 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7093627
28 September 2020 COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7062906
23 March 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6930563
26 October 2019 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6837301
29 July 2019 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6765855
31 August 2018 Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6522221

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 28 September 2020 Resolved
The arrangement of the water seal or equivalent devices and its associated fittings shall be such that it will prevent backflow of vapors and liquids and will ensure the proper functioning of the seal under operating conditions. Deck water seal level indicating device housing was found with the two lower bolts broken off inside the deck water seal. Vessel currently has two turnbuckles wedged between deck piping and the level indicating device housing to keep the device from leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2020
Resolved 29 September 2020
Resolution: Received class report attesting to repairs of deck water seal level housing.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 28 September 2020 Resolved
In addition to the requirements of paragraph 2.2.4.5, audible and visual alarms shall be provided to indicate lower water in the water seal. Vessels deck water seal level indicating device is not operational.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2020
Resolved 11 November 2020
Resolution: Received and reveiwed class report attesting to proper function of Deck water seal indicating device.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.