DocumentationValid · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton 19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2025Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons under normal and emergency conditions. Duty Marine Inspector was made aware of a ruptured hydraulic hose in the steering system. Submit a video demonstrating satisfactory operation of the hydraulic steering system from full port to full starboard rudder and a root cause analysis and corrective action report signed by the vessel master prior to conducting commercial operations.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: In-kind replacement hose installed and sufficient video evidence of operation of the steering systems submitted.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 February 2025Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces.
Vessel is unable to close ventilation in E/R in case of fire and release of fixed firefighting agent. Provide plans for repair/ coming into compliance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 March 2025
Resolved 30 May 2025
Resolution: E/R ventilation (x4 intakes) can now be secured manually
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight.
Cable penetrations in E/R going into chain locker space did not utilize approved watertight/ fire resistant materials.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 30 May 2025
Resolution: Watertight transit connection has been installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2025Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Explosion proof lighting in E/R not properly installed. Repair to satisfactory condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2025
Resolved 30 May 2025
Resolution: Existing 12v explosion proof fixtures replaced with new/correct fixtures
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 July 2023Resolved
Vessel must have high bilge level alarms. FWD space on vessel has bilge suction, but no high level alarm.
46 CFR 143.230
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2023
Resolution: Installed alarm.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 July 2023Resolved
Vessel must have visible and audible Low hydraulic steering fluid level alarm at the operating station. No alarm present.
46 CFR 143.230
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2023
Resolved 8 August 2023
Resolution: Installed alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 July 2023Resolved
Closure devices, must be provided for all hull penetrations which open to the exterior of the vessel and which may allow water to enter the vessel. Vessel has non-metallic ovbd discharge connection without a valve.
46 CFR 144.320(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2023
Resolved 8 August 2023
Resolution: Installed metallic ovbd discharge.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2023Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. No more than four conductors shall be secured to anyone terminal stud. Vessel had six connections on one stud.
46CFR143.400(a)
ABYC E.9.16.k(10)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2023
Resolved 8 August 2023
Resolution: Removed excess electrical connections.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 May 2021Resolved
Provide audible alarm at operating station for bilge high level alarm.
46 CFR 143.230 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 26 August 2021
Provide low hydraulic steering fluid alarm that is visible and audible at operating station for steering hydraulic oil reservoir.
46 CFR 143.230 (a) (6)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 26 August 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 May 2021Resolved
Provide EPIRB with non expired battery for vessel.
46 CFR 141.230
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 26 August 2021