Records from 1993 to 2011. Most recent: operational control imposed, 8 November 2011.
Inspection history · 22
8 November 2011
ILO-147 Exam · Loadline Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4185085
2 November 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4185186
25 June 2008
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3249030
18 March 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2890909
28 August 2006
MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2762554
4 January 2005
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2268634
6 December 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2259505
1 September 2004
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2185002
2 June 2004
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086647
24 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2025321
28 February 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1765851
28 July 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 181807
9 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 70746
21 October 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 112932
26 October 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 156123
13 September 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 4617
30 December 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 41837
22 March 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 676365
11 March 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 538104
28 February 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 66601
22 September 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 643133
9 September 1993
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 158869
Engineering › Freshwater System (jacketwater cooling) › Containment
Issued 2 December 2011
Resolved
Fresh water cooling system for Generator # 2 has multiple leaks
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2011
Resolution: Satisfactory repair witnessed by port state inspector
Construction/Loadline › Markings › Load Line Mark
Issued 8 November 2011
Resolved
The vessel's load line mark does not match its International Load Line certificate and is not permanently marked. ILLC REG 5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2011
Resolution: Load line mark has been permanently marked and painted on the hull.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 November 2011
Resolved
Post for railing starboard aft upper deck has been broken off its base. There is also a one meter gap in the railing in that area. ILLC REG 25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2011
Resolution: Railings and stanchions have been repaired to satisfactory condition.
Stability › Weathertight Integrity › General
Issued 8 November 2011
Resolved
Several weathertight doors incapable of keeping water out in all sea conditions. ILLC REG 12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2011
Resolution: Doors were repaired to original weathertightness.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 8 November 2011
Resolved
All toilets onboard are inoperable. PWSA 33USC1223(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2011
Resolution: Toilets on the vessel were examined and found to be restored to satisfactory operation.
Engineering › Bilge Water Management System › Not Operational
Issued 8 November 2011
Resolved
Bilge pump non-functional, which has implications for the safety of the crew. PWSA 33USC1223(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2011
Resolution: Inspectors verified operational test of bilge pump.
Construction/Loadline › Structures › Manhole
Issued 8 November 2011
Resolved
Deck opening from towing gear room is missing its permanent cover. PWSA 33USC1223(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2011
Resolution: Deck opening''s permanent cover is in place.
Fire Fighting › Fire Pumps › Bushes
Issued 8 November 2011
Resolved
Fresh water leak from fire station valve above fire pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2011
Resolution: Port State Inspector witnessed statisfactory test of fire pump after part was replaced.