ELECTRA is a 2005 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in January 2023, along with 6 deficiencies and 3 operational controls.

Records from 2016 to 2023. Most recent: inspection, 13 January 2023.

Built
2005
Last inspected
13 January 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 January 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9307815
924112
Flag
LIBERIA
Maury page id
psix-924112

Documentation record

Tonnage as PSIX records it13712 - Convention (Subpart B), Net Ton
61119 - Displacement, Metric Ton
50903 - Dead Weight, Metric Ton
30053 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

13 January 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7621167
13 April 2022 COC-CHEM Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7428092
25 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7339364
28 July 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7270967
26 January 2021 COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7128548
2 March 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6919036
14 February 2020 COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6907767
15 August 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6784018
2 July 2019 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6733157
12 February 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6617676
16 April 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6392268
14 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6391644
25 March 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6378067
4 March 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6365502
6 November 2017 ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6301423
25 April 2016 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5858739

Deficiency record · 6

12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 13 April 2022 Resolved
ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH THE STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED 02 ELECTRICAL INSTALLATIONS COMPROMISED ON PORT AND STARBOARD SIDE FORWARD OF #1 CARGO TANK. THE ELECTRICAL LIGHTING HOUSING HAD WATER ACCUMULATED INSIDE. PSCO WAS PROVIDED REQUISITION #Y0034P REQUESTING 04 NEW LIGHTS. 74SOLAS(2) VII/10.1 1BC 10.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 April 2022
Resolved 13 April 2022
Resolution: Vessel provided requisition requesting 04 new lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 February 2020 Resolved
The load line shall be permanently marked on the sides of the ship to the satisfaction of the Administration. PSCO observed load line was not permanently marked on the side of the vessel. ICLL (88 proto) 2005 edition, Annex I/8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2020
Resolved 2 March 2020
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 6 November 2017 Resolved
Audible alarm was found to be inoperable upon testing. 46CFR2013(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 November 2017
Resolution: Crew replaced alarm, tested satisfactory.
Deck/Cargo › Holds/Tanks › Ullage
Issued 6 November 2017 Resolved
Residual oil tank filled past overfill alarm set point of 98.5% 46CFR39.3001(e)(1) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: SEC HOU-GAL PSC received a class report from DNV-GL satisfying the requirement.
Engineering › Fuel Oil Service System › Piping
Issued 6 November 2017 Resolved
1410- Port side fuel line leading into fuel injector on #3 cylinder on main diesel engine leaking fuel oil. 74SOLAS(14)II-2/4.2.2.5.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: SEC HOU-GAL PSC received a class report from DNV-GL satisfying the requirement.
Lifesaving › Lifeboat › Hatches
Issued 6 November 2017 Resolved
0610- Starboard lifeboat entry door gasketing material is wasted at the top of the frame, reducing watertight capability of the door. 74SOLAS(14)III/34 LSA Code 4.6.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: SEC HOU-GAL PSC received a class report from DNV-GL satisfying the requirement.

Ownership record