ELECTRA is a 2005 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in January 2023, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2023. Most recent: inspection, 13 January 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it13712 - Convention (Subpart B), Net Ton 61119 - Displacement, Metric Ton 50903 - Dead Weight, Metric Ton 30053 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
16 inspections, each with its date, unit and type; 6 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
13 January 2023Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7621167
13 April 2022COC-CHEM Annual · Administrative Inspection · PSC B
12 - Dangerous Goods › N/A - No Subsystem › Other (tankers)
Issued 13 April 2022Resolved
ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH THE STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION.
PSCO OBSERVED 02 ELECTRICAL INSTALLATIONS COMPROMISED ON PORT AND STARBOARD SIDE FORWARD OF #1 CARGO TANK. THE ELECTRICAL LIGHTING HOUSING HAD WATER ACCUMULATED INSIDE.
PSCO WAS PROVIDED REQUISITION #Y0034P REQUESTING 04 NEW LIGHTS.
74SOLAS(2) VII/10.1 1BC 10.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 April 2022
Resolved 13 April 2022
Resolution: Vessel provided requisition requesting 04 new lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 February 2020Resolved
The load line shall be permanently marked on the sides of the ship to the satisfaction of the Administration. PSCO observed load line was not permanently marked on the side of the vessel.
ICLL (88 proto) 2005 edition, Annex I/8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 March 2020
Resolved 2 March 2020
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 6 November 2017Resolved
Audible alarm was found to be inoperable upon testing. 46CFR2013(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 November 2017
Resolution: Crew replaced alarm, tested satisfactory.
Deck/Cargo › Holds/Tanks › Ullage
Issued 6 November 2017Resolved
Residual oil tank filled past overfill alarm set point of 98.5% 46CFR39.3001(e)(1) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: SEC HOU-GAL PSC received a class report from DNV-GL satisfying the requirement.
Engineering › Fuel Oil Service System › Piping
Issued 6 November 2017Resolved
1410- Port side fuel line leading into fuel injector on #3 cylinder on main diesel engine leaking fuel oil. 74SOLAS(14)II-2/4.2.2.5.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: SEC HOU-GAL PSC received a class report from DNV-GL satisfying the requirement.
Lifesaving › Lifeboat › Hatches
Issued 6 November 2017Resolved
0610- Starboard lifeboat entry door gasketing material is wasted at the top of the frame, reducing watertight capability of the door. 74SOLAS(14)III/34 LSA Code 4.6.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2017
Resolution: SEC HOU-GAL PSC received a class report from DNV-GL satisfying the requirement.