← All vessels
OCEAN LEE
Industrial Vessel · Miscellaneous Vessel class · Built 2000s · USCG Oceania District (CGD-O) · Other hulls named OCEAN LEE
OCEAN LEE is a 2008 industrial vessel. The Coast Guard has recorded 28 inspections since 2008, most recently in May 2026, along with 19 deficiencies, 1 operational control and 1 casualty investigation in 2010.
Records from 2008 to 2026. Most recent: inspection, 11 May 2026.
- Built
- 2008
- Last inspected
- 11 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2010
Identity
1205367
9464297 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP8806
924421
Flag
UNITED STATES
367362000, 368393740
Maury page id
psix-924421
Inspections, by type
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
Registered tonnagegross 2,409 / net 829
ITC dimensions (L × B × D)246.6 ft × 52.0 ft × 19.0 ft
ITC tonnagegross 2,409 / net 829
BuilderBENDER SHIPBUILDING & REPAIR CO INC · MOBILE, AL, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 October 2025 · expires 31 October 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it829 - Convention (Subpart B), Net Ton
2541 - Dead Weight, Ton
2409 - Convention (Subpart B), Gross Ton
2541 - Dead Weight, Ton
2409 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP8806MMSI 368393740 · active · compulsorily equipped · granted 13 November 2024, expires 13 November 2034
WDE4932MMSI 367362000 · active · compulsorily equipped · granted 14 March 2018, expires 30 May 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 28
11 May 2026
Deficiency Check · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8375111
2 December 2025
MTSA/ISPS Verification · COI Inspection · Re-Inspection · ACP COI Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8272991
22 May 2025
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8141174
30 April 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8126402
19 November 2024
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8037024
8 November 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8032522
1 May 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7904525
11 March 2024
ACP Annual Oversight · Administrative Inspection · Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7874914
29 September 2023
Administrative Inspection · ACP Drydock Oversight
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7802206
21 July 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7760337
20 March 2023
MTSA/ISPS Verification · Deficiency Check · Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7653977
4 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7558852
12 July 2022
Construction Oversight · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7505154
11 April 2022
Administrative Inspection · ACP Annual Oversight · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7428565
28 December 2020
MTSA/ISPS Verification · Re-Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7115643
13 November 2020
Permit to Proceed
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7094738
5 October 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6016478
5 April 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876520
20 January 2016
Periodic Inspection · MTSA/ISPS Verification · ACP Periodic Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5790439
28 August 2014
MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4966845
20 October 2010
ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3873815
30 July 2009
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3550392
18 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3419710
12 December 2008
MTSA/ISPS Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3378758
20 October 2008
DAPI Audit · Initial Certification · ACP COI Oversight · MTSA/ISPS Verification · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3348447
16 October 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3345756
16 October 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3345763
22 September 2008
Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3330397
Deficiency record · 19
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 December 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. During inspection for COI, USCG Marine Inspector found that fire damper for EDG space was hard to operate correctly and that there were several cable runs that were not properly hung with metal bands as per ABS rules.
74 SOLAS (20 cons.) I/11(a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2025
Resolved
Design Verification and Periodic Safety Test Procedures (PSTP) documents…must be retained aboard the vessel. The PSTP procedures and documents onboard the vessel are for a “sister vessel” of a different hull number, and the PSTP procedures that the recent attending ABS surveyor was initially able to provide was also for a separate “sister vessel” of a different hull number; in addition, at the time of the inspection, there was no documentation for annual or other frequency PSTP checks that occurred within the preceding 12 months (the last recorded checks were mostly from July through November of 2024). Provide Class approved PSTPs specific to the vessel or Class letter providing that the PSTPs for the other “sister vessels” are approved and acceptable for this specific vessel, and ensure that all PSTPs have been completed/documented for 2025.
46 CFR 8.430
U.S. SUPPLEMENT TO ABS RULES … 2003
4-9-1/7
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 3 December 2025
Resolved
Intact stability for cargo and passenger vessels is to comply with the applicable parts of Subchapter S. Vesel has a Trim and Stability booklet that was approved 28OCT2010. Since this time, several modifications have been made to the vessel that include a vehicle ramp that was added to the transom and containers on an upper deck. Additionally, during inspection, vessel did not have Trim and Stability Book or a Stability Letter onboard. Determine need for stability review and make changes as required. Provide updated and approved Trim and Stability Booklet that reflects changes made since 2010 approval. Provide approved Stability Letter. Ensure approved documents are onboard vessel.
46 CFR 8.430
U.S. SUPPLEMENT TO ABS RULES … 2003
3-3-1/3.1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 November 2024
Resolved
Electric installation and electric equipment particulary the newly added AC unit above the main engine room switch board, must be inspected to determine mechanical and electrical condition and performance.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 November 2024
Resolved
Main switchboard enclosure has holes cut in top and AC ductiing piping run to the holes. Prove that this meets safety and construction requirements.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 20 March 2023
Resolved
Vessel did not conduct drills during inspection. Conduct drills prior to commercial operation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 July 2022
Resolved
Unless expressly provided otherwise in this regulation, at least two widely separated and ready means of escape shall be provided from all spaces or groups of spaces. Upper Portable Accommodation Space (PAM) recently installed on top of another PAM located on the main deck has two (02) escape hatches located on the outside of each accommodation space. There is no means to climb down from the hatches indicated. Repair prior to using PAMS. IAW 74 SOLAS (2004) II-2 13.2.1
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 12 April 2022
Resolved
Life-saving appliances and arrangements required by this chapter shall be approved by the Administration. The rescue boat construction no longer meets 46 CFR 160.156, fiberglass patch exists on the stern gunwale. Unapproved repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Equipment (including exemption)
Issued 12 April 2022
Resolved
All life-saving appliances shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. The rescue boats grab line was missing with attachment and the retro tape was defective.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 November 2020
Resolved
Each OSV must be placed in Dry-Docking or hauled out for examination twice each 5 years with no interval between examinations exceeding 3 years. Vessel is past due a dry-docking. Vessel shall not operate for hire until a complete dry-docking exam has been credited. Vessel may proceed from laid up berth to Bollinger shipyard for dry-docking.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 20 January 2016
Resolved
New dryer installed onboard is not wired in accordance with UL or 46 CFR 111. Dryer is not secured properly, wiring is not wired to code, and ventilation is insufficient. Prove proper installation to the satisfaction of attending USCG MI or attending ABS Surveyor.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 20 January 2016
Resolved
SOLAS Training manual is not in the working language of the crew. Both English/Spanish versions do not match. Spanish version does not include updated equipment/procedures currently on board the vessel.
Fire Fighting › Fire Pumps › Arrangement
Issued 20 January 2016
Resolved
During testing of ship's fire pump, crew had all required valves closed and was unable to prove "ready for operation" to attending MIs. All valves have been opened and training has been conducted with the crew.
Fire Fighting › Structural - A Class Divisions › Stairways
Issued 20 January 2016
Resolved
Fire Doors throughout vessel are not fully operational (self-closing), primarily in the stairway. Make adjustments and prove proper operation to attending USCG MI or ABS Surveyor.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 20 January 2016
Resolved
Paint lockers on 02 deck have seized up dogs and wastage around knife edges, missing portions of gasket. repair and make adjustments to satisfaction of attending USCG MI or ABS Surveyor.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 January 2016
Resolved
During testing of vessel's OWS (MEPC 107.49), Chief Engineer was unable to prove proper operation of OWS, no change was observed in the water coming from overboard discharge. Prove proper operation to attending ABS Surveyor.
Lifesaving › Lifebuoys › Serviceable
Issued 20 January 2016
Resolved
Stbd side bridge buoy's plug is cracked and needs to be replaced. Replace to satisfaction of attending USCG MI.
Communications › Alarms/Indicators › General Alarm
Issued 20 January 2016
Resolved
Vessel's general alarm is not operable in the engine room or the tank farm. Prove proper operation to the satisfaction of the attending USCG MI or class surveyor.
Fire Fighting › Means of Escape › Blocked
Issued 20 January 2016
Resolved
Escape hatches from steering gear, cargo room compartments were not operational from the inside and shows signs of water egress. Make adjustments and prove proper operation to attending ABS Surveyor or USCG MI.
Casualty record · 1
3 July 2010Routine · role: Involved in a Marine Casualty · activity 3914201
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
SEACOR LEE (2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.