Records from 2016 to 2026. Most recent: inspection, 3 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)38.0 ft × 14.0 ft × 5.5 ft
Registered tonnagegross 19 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVANS BOAT REPAIR INC · CRISFIELD, MD, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKEYPORT, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Net Ton
19 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
23 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 23
3 May 2026
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 8361263
22 April 2026
Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8331126
9 October 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8250054
12 May 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8133465
15 May 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7909896
27 October 2023
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7815414
15 June 2023
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7715869
8 May 2023
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7654294
3 April 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7661712
6 July 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7652700
21 June 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7482424
9 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7367048
28 June 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7233511
7 July 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6992538
26 November 2019
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6859970
10 July 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6751713
17 June 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6710257
9 April 2018
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6383157
1 December 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6315897
27 June 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6187239
1 August 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5966910
19 July 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5941636
15 July 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5941648
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2026
Resolved
Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose, which. Install an additional clamp on MDE exaust flex hose connections. 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 28 April 2026
Resolution: Each end of the Exaust flex house is now double clamped.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 April 2026
Resolved
Vessel must carry adequate and up-to-date charts, US coast Pilot, and light list. Vessels Light list and Coast pilot were out of date. Update light List and coast pilot.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2026
Resolved 28 April 2026
Resolution: Coast pilot and light list updated.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 May 2024
Resolved
46 CFR 184.420(a)(1): A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel was unable to provide up-to-date electronic charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 26 May 2024
Resolution: Photo of updated chart received.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2024
Resolved
46 CFR 185.614: Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. CORRECTED ON THE SPOT.
Action required: 10 - Deficiency Rectified
Due 15 May 2024
Resolved 15 May 2024
Resolution: DISTRESS SIGNALS clearly marked on exterior of container.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2023
Resolved
A vessel on an oceans route must carry 6 hand red flare distress signals approved IAW 160.021 in subchapter Q and 6 hand orange smoke distress signals approved IAW 160.037 in subchapter Q. Vessel only had 6 red hand flares on board. 46CFR180.68(a)
Action required: 10 - Deficiency Rectified
Due 15 June 2023
Resolved 15 June 2023
Resolution: Vessel was able to supply 6 additional red flares to substitute for the 6 orange flares before completion of exam in IAW 46CFR180.68(c)(2)(ii).
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 June 2022
Resolved
An inflatable life raft must be serviced at a facility specifically approved by the Commandant for the particular brand, and in accordance with servicing procedures meeting the requirements of part 160, subpart 160.151 no later than the month and year on its servicing sticker affixed under 46 CDR 160.151-57. Found (01) inflatable life raft servicing expired. Have serviced by appropriate life raft servicing company. Vessel is restricted to limited coastwise NMT 3NM from shore. 46CFR185.730(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2022
Resolved 6 July 2022
Resolution: Vessel O/O submitted servicing reports
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 June 2022
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel could not provide annual fire servicing certificate for their pre-engineered fire system or portable fire extinguishers. Vessel must provide evidence of the required servicing to the marine inspector. 46CFR176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2022
Resolved 6 July 2022
Resolution: Vessel O/O submitted servicing reports.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2021
Resolved
Inspectors found multiple holes in the aft bulkhead of the engineroom, leading into the space containing the fuel tank. These holes were located on both the port and starboard sides, near the overhead.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Operator repaired holes using CG approved fire retardant resin over plywood core.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 July 2020
Resolved
Each vessel that operates on the high seas, or that operates beyond three nautical miles from the Coastline, must have on board a FCC Type Accepted CAT 1, 406 MHz EPIRB. Found EPRIB hydrostatic release expired and NOAA registration expired. Provide documentation of new release and NOAA registration. Restricted to no more than 3 nm from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 21 July 2020
Resolution: Master produced EPIRB registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020
Resolved
Electrical equipment must be installed and maintained to provide safety under normal or emergency conditions. Protect passengers and crew from electrical hazards, fire, electrical shock and to minimize accidents. Found battery charger plugged into an extension cord running through multiple bulkheads. Remove extension cord to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 21 July 2020
Resolution: Master removed extension cord and hard wired battery charger with manufacturer approved wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 June 2019
Resolved
Found (01) inflatable liferaft servicing expired 02/28/2019. Have serviced by appropriate life raft servicing company. Limited to 15 total persons onboard while on oceans route.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2019
Resolved 10 July 2019
Resolution: Coast Guard received and email with the attached life raft certificate of re-inspection for OCEAN PEARL's life raft.
Navigation › Piloting/Steering › Marine Charts
Issued 19 July 2016
Resolved
Found (back-up) Navigation chart expired by 3 years. vessel must show proof of up-to-date Navigation Chart.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 1 August 2016
Resolution: Provided updated charts.
Lifesaving › Lifefloat › Float-free Link
Issued 19 July 2016
Resolved
Found floatfree link missing it's identification tag showing proof of capacity. Provide new link with identification tag attached, displaying the proof of capacity. Vessel may only carry 16 total persons on oceans and coastwise routes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2016
Resolved 1 August 2016
Resolution: Replaced float free weak link with a new one of adequate capacity.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 July 2016
Resolved
15 July 2016, Vessel's Annual inspection is overdue Vessel is restricted from operating with more than six passengers for hire, prior to completing annual inspection.
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 19 July 2016
Resolution: Completed Annual inspection, vessel is considered fit for the service and route shown on the Certificate of Inspection.