MAURY USCG vessel records
← All vessels

HARD HAT

HARD HAT is a 1966 towing vessel. The Coast Guard has recorded 24 inspections since 1987, most recently in November 2025, along with 25 deficiencies and 1 operational control.

Records from 1987 to 2025. Most recent: inspection, 25 November 2025.

Built
1966
Last inspected
25 November 2025
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 25 November 2025
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 15 calendar years (1987–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8107
Flag
UNITED STATES
Maury page id
psix-92686

Documentation record

Registered dimensions (L × B × D)38.0 ft × 18.0 ft × 5.2 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGRAFTON BOAT CO INC · GRAFTON, IL, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBRIDGEWATER, PA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

25 November 2025 TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8287361
18 June 2024 Deficiency Check · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7938245
12 April 2024 TPO Audit
Administrative · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 7894130
27 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7799076
8 September 2023 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7780536
25 October 2022 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7583997
23 September 2022 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7560200
28 October 2021 Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7342056
16 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7281580
28 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7018337
26 March 2019 Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6649670
29 May 2012 Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4329649
2 February 2012 Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4236810
20 October 2011 Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4172843
14 August 2001 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 214341
19 July 2000 Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1052061
11 May 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 214127
11 May 2000 Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 818455
5 May 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 138586
5 May 2000 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 223854
7 February 1998 Uninspected Towing Vessel
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 774291
15 August 1995 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 89122
15 March 1988 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 322060
20 March 1987 Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 314984

Deficiency record · 25

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 June 2024 Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals: A vessel that is exposed to salt water not more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least once every 5 years.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2024
Resolution: Recieved objective evidence from TPO that the Drydock/ISE were conducted on June 17, 2024. document uploaded.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 8 September 2023 Resolved
The master of a towing vessel must ensure that each crewmember participates in fire-fighting drills and receives instruction at least once each month. The instruction may coincide with the drills, but is not required to do so. All crewmembers must be familiar with their fire-fighting duties. This vessel has not been utilized in several months. Firefighting drill have not been completed as required and crew was not familiar with their duties. Complete fire drills on this vessel and conduct proper fire drill in the presence of a CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 October 2023
Resolution: Drills conducted sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 8 September 2023 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of § 140.640, assess operational risks, and anticipate and manage workload demands. No completed navigation assessments or unfilled navigation assessments found on vessel. Provide master with a means to record navigation assessments in accordance with 46 CFR 140.635 and ensure its completion prior to getting underway.
Action required: 10 - Deficiency Rectified
Resolved 5 October 2023
Resolution: Navigation assessment onboard and conducted in presence of attending inspector.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 8 September 2023 Resolved
Prior to getting underway for the first time on a particular towing vessel, each crewmember must receive a safety orientation on: (1) His or her duties in an emergency; (2) The location, operation, and use of lifesaving equipment; (3) Prevention of falls overboard; (4) Personal safety measures; (5) The location, operation, and use of Personal Protective Equipment; (6) Emergency egress procedures; (7) The use and operation of watertight and weathertight closures; (8) Responsibilities to provide assistance to individuals that are not crewmembers; (9) How to respond to emergencies relative to the tow; and 10) Awareness of, and expected response to, any other hazards inherent to the operation of the towing vessel which may pose a threat to life, property, or the environment. Newly hired crew members have not completed required training on this vessel. Conduct training and document as required.
Action required: 10 - Deficiency Rectified
Due 9 October 2023
Resolved 5 October 2023
Resolution: Training conducted and documented. Company working with consultant to enhance training program.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 8 September 2023 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Engine alarm set points are not set to manufacturers requirements and main engine RPM not displaying. Reprogram set points and repair tachometer as required. Tachometer repaired. 30 day Extension granted to allow for technician to adjust/upgrade engineering alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2023
Resolved 8 November 2023
Resolution: Alarm set points entered as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2023 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room and pilot house breaker panels have exposed contacts from missing breakers. Provide means to prevent accidental contact of exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 October 2023
Resolved 5 October 2023
Resolution: Spare breakers installed and labelled in openings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2023 Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, or 160.176, for each person on board. Vessel missing (1) approved life jacket. Provide life jacket as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2023
Resolved 5 October 2023
Resolution: Approved type lifejacket placed onboard.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 September 2023 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. Windows in engine room are only capable of being closed from inside the engine room. Provide means to secure ventilation from outside the engine room.
Action required: 10 - Deficiency Rectified
Due 9 October 2023
Resolved 5 October 2023
Resolution: Metal engine room window covers installed. Operational test sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 September 2023 Resolved
The owner, managing operator, or master of each towing vessel must maintain the required navigational-safety equipment in a fully-functioning, operational condition. Starboard running light not working and mast head light is equipped with a household light bulb. Repair both lights as required.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 October 2023
Resolved 9 October 2023
Resolution: Masthead light replaced with LED and STBD running light bulb replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 September 2022 Resolved
Means must be provided for closing, in case of fire, each machinery space doorway, ventilator, and annular space around funnels. Second deck of engine room has fixed vent with no way to secure. Provide method to close vent.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 26 October 2022
Resolution: Ventilation duct closed off
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical outlet cover on bridge missing and j-box for lights missing. Repair covers as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 26 October 2022
Resolution: Electrical items corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 September 2022 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. Portable fire pump not self priming. Provide self priming pump as required.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 26 October 2022
Resolution: Installed foot valve on suction line to facilitate self priming
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 September 2022 Resolved
Each lifebuoy on a towing vessel must Be approved under approval series 160.050 or 160.150. Materials - Grab line. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab line for all lifebuoys wasted. Repair or replace as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 26 October 2022
Resolution: Replaced all lifebuoys with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 September 2022 Resolved
Repairs and minor alterations to existing towing vessels must be made in accordance with this part. New installations that are not replacements in kind must comply with the requirements of Subpart C of this part (starting at 46 CFR 143.500), if applicable. Ship service generator replaced with upgraded system. Provide verification of compliance with the construction and arrangement design standards as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2022
Resolved 21 December 2022
Resolution: Design verfication completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 September 2021 Resolved
Stowage positions for life jackets must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the life jackets stowed inside the container. Life jacket storage containers missing number of life jackets throughout the vessel. Add quantity as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 28 October 2021
Resolution: Location marked as required.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 September 2021 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. The portable fire pump must be self-priming and power-driven. Portable fire pump is not self-priming. Make necessary repairs to make pump self priming.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 28 October 2021
Resolution: Installed non-return valve to pump suction. Pump now seld priming.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 16 September 2021 Resolved
Each window or portlight, and its means of attachment to the hull or the deckhouse, must be capable of withstanding the maximum expected load from wind and waves, due to its location on the vessel and the vessel's authorized route. Aft bridge window cracked. Replace as required.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 28 October 2021
Resolution: Window replaced with new.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2021 Resolved
The original COI must be framed under glass or other transparent material and posted in a conspicuous place onboard the towing vessel. COI was not properly stored. Stored as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 28 October 2021
Resolution: COI posted as required.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 June 2019 Resolved
Excessive amounts of oil and sludge buildup in the engine room bilge. Remove built up sludge and oil from bilges to the satisfaction of the attending CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 29 July 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2019 Resolved
Remotely operated fuel shutoff valves are not located directly outside of the fuel oil supply tank. Re-locate valves and remote operations cable to the piping directly outside of the fuel oil supply tanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 29 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 June 2019 Resolved
No accurate method provided to determine if the portable fire pump meets the minimum capacity of at least 80 gallons per minute and a minimum discharge pressure of not less than 60 pounds per square inch measured at the pump discharge. Provide proof of minimum flow rate and discharge pressure. Provide means or method used to determine flow rate and discharge pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 26 June 2019 Resolved
Navigation assessments are vague in nature as written, and do not consider all elements of the pilothouse resource management and must consider changes in conditions, equipment, crew knowledge/qualifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 22 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2019 Resolved
Required Chemical Testing Program does not display Employee Assistance Program informational material to include at a minimum: community service hot-line telephone number for crewmember assistance and employer's policy regarding drug and alcohol use in the workplace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2019 Resolved
Vessel does not a documented fuel maintenance plan for the main engines and generator to insure a clean fuel supply is provided. Maintenance plan shall include at a minimum: Fuel filter/water separator replacement intervals, where filters are used, and minimum amount of spares are kept on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 22 July 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2019 Resolved
No proof that vessel personnel or company have knowledge or are in compliance with the United States Environmental Protection Agency (EPA) National Pollutant Discharge Elimination System (NPDES) Small Vessel General Permit for Discharges Incidental to the Normal Operation of Vessels Less than 79 Feet (sVGP).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 August 2019

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.