MAURY USCG vessel records
← All vessels

MSC ROSARIA

MSC ROSARIA is a 2007 freight ship. The Coast Guard has recorded 16 inspections since 2016, most recently in July 2026, along with 9 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 1 July 2026.

Built
2007
Last inspected
1 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 July 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9320453
926922
Flag
PANAMA
Maury page id
psix-926922

Documentation record

Tonnage as PSIX records it30224 - Convention (Subpart B), Net Ton
82672 - Displacement, Ton
63581 - Dead Weight, Ton
50963 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

1 July 2026 In-Service Inspection · Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8421097
1 July 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8456656
29 January 2026 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8303616
26 November 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8274159
24 November 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8273090
22 May 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8141584
23 April 2025 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8118580
28 February 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8082439
22 April 2024 PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7895959
14 February 2024 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7866167
17 December 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7839837
18 March 2023 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7652944
14 March 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650587
13 March 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7650348
3 February 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6341831
8 February 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5811156

Deficiency record · 9

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported an alarm while shifting from slow ahead to deadslow ahead and was forced to return to slow ahead, unable to maintain desired command. 74 SOLAS (20) 1/11(a) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2026
Resolution: SECDELBAY Port State Control Duty Officer received a class report from DNV attesting to the satisfactory repair and testing of ahead/astern propulsion. Vessel is cleared to depart Captain of the Port zone.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 26 November 2025 Resolved
“THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND.” DECK LINE ON PORT AND STARBOARD SIDE IS PAINTED WHITE ON A WHITE BACKGROUND.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2026
Resolution: Vessel submitted supporting documents attesting to the correction of the deck line.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2023 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores or similar spaces, unless the Administration is satisfied that such equipment is appropriate to the space concerned. PSCOs observed that the material condition of the explosion proof lighting in the battery room and paint locker rendered them inappropriate for the spaces. 74 SOLAS (04) II-1/45.10.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2024
Resolved 16 February 2024
Resolution: Please see attached Class survey report regarding the replacement of explosion proof lighting.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 March 2023 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with a second source of energy for an additional three starts within 30 minutes unless manual starting can be demonstrated to be effective. Second source of energy / manual starting proved to be in effective. 74 SOLAS (04) II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Conducted maintenance on air start.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 March 2023 Resolved
Means shall be provided to control leaks of flammable liquids. Found small accumulations of diesel in purifier room due to fuel change over. 74 SOLAS (09) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Cleaned up diesel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 March 2023 Resolved
Means shall be provided to control leaks of flammable liquids. Observed minor oil leak on aux engine #3 cylinder 6. 74 SOLAS (09) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Fixed leak, cleaned oil.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 March 2023 Resolved
Doors shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Fire door on second deck of engine room leading to fire escape was not self-closing. 74 SOLAS (09) II-2/9.4.1.1.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Adjusted tension on fire door.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 March 2023 Resolved
Hoses specified in this chapter as “fire hoses” shall, together with any necessary fittings and tools, be kept ready for use in conspicuous positions near the water service hydrants or connections, observed spanner wrench missing from fire house station on the bottom deck engine room port side. 74 SOLAS (09) II-2/10.2.3.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Replaced spanner wrench with a spare.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 14 March 2023 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected, observed multiple minor steam leaks in purifier room. 74 SOLAS (04) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 March 2023
Resolved 14 March 2023
Resolution: Replaced gaskets and tightened steam connections.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.