MAURY USCG vessel records
← All vessels

LORELEI

LORELEI is a 2007 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in January 2023, along with 10 deficiencies and 3 operational controls.

Records from 2016 to 2023. Most recent: inspection, 26 January 2023.

Built
2007
Last inspected
26 January 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 January 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9314179
927072
Flag
MARSHALL ISLANDS
Maury page id
psix-927072

Documentation record

Tonnage as PSIX records it42531 - Convention (Subpart B), Gross Ton
21474 - Convention (Subpart B), Net Ton
73673 - Dead Weight, Metric Ton
88282 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPTAIN W. D. HADEN Towing Vessel · MISLE 183971 · 25 September 2016 · activity 6011582HARRIS II Towing Vessel · MISLE 435907 · 25 September 2016 · activity 6011582

Inspection history · 13

26 January 2023 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7626813
6 December 2021 Appeal
Administrative · Commandant (CG-CVC) · Activity 7363186
15 October 2021 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7333483
9 October 2021 COC-TVE Renew · Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7326536
28 August 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6253708
23 August 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6249200
16 December 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6058967
12 December 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6056107
25 November 2016 MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6047356
26 September 2016 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6009374
25 September 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6011582
30 August 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5987522
18 August 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5976161

Deficiency record · 10

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 9 October 2021 Resolved
15105 – Resources and Personnel - Every Company should develop, implement and maintain a safety management system (SMS) which includes the following functional requirements: instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant Int and Flag State legislation. Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: The vessel failed to fully implement the requirements of the ISM code through their SMS procedures as evident by the following identified deficiencies indicating that the ship and/or company are not meeting the SMS requirements. Recommend an external audit. No. 1 – Crew is not familiar with valve alignment procedures for boiler startup. PSCO witnessed crew misalign valves for boiler, resulting in a low water alarm and safety shutdown of the boiler. No. 2 – Crew is not familiar with testing procedures for inert gas system alarms. PSCO witnessed crew close scrubber water discharge valve resulting in a backflow of water that leaked out of the piping from the scrubber to the boiler. No. 3 – Crew is not familiar with proper testing procedures for fixed fire detection systems. PSCO witnessed crew test 02 detectors in the engine room, unknowingly discharging water mist system. Vessel personnel were not familiar with the established procedures for shipboard operations. The crew was unable to provide written procedures for testing essential or critical equipment. - 74 SOLAS (20) IX/3.1 & ISM Code Part A/1.4.2 - 30ac
Action required: 30 - Ship detained
Due 9 October 2021
Resolved 12 October 2021
Resolution: RO attended the vessel and conducted an external audit revealing two non-conformities. CAR and root cause submitted to RO and Flag State. PSCO attended vessel and verified crew were familiar with SMS. Witnessed testing of IG using SMS procedures.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 October 2021 Resolved
07111 - Personal Equipment for Fire Safety - In tankers, 4 fire-fighter’s outfits shall be provided. Three sets of the fire-fighter’s outfits had holed gloves, two had trousers with tears, and one had a frayed damage hood. Only 1 fire-fighter’s outfit is fully operational. - 74 SOLAS (04) II-2/10.2.3 - 30ac
Action required: 30 - Ship detained
Due 9 October 2021
Resolved 10 October 2021
Resolution: Four new fire fighter outfits were supplied and found onboard during the RO survey.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2021 Resolved
13199 - Other (Machinery) - Machinery boilers and associated piping systems shall be of a design and construction adequate for the service for which they are intended. PSCO observed active steam leak inside purifier room. - 74 SOLAS (04) II-1/26 - 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2021
Resolved 10 October 2021
Resolution: Crew and RO determined leaks were from a steam return line. Two leaks identified, Fwd purifier room and above fresh water generator. All piping temporarily repaired to satsifaction of RO. Permanent repairs due to RO Dec, 10, 2021.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 October 2021 Resolved
07105 - Fire Doors/Openings in Fire-Resisting Divisions - The purpose of this regulation is to contain a fire in the space of origin. The fire integrity of the divisions shall be maintained at openings. 02 A-class fire doors leading from engine room to steering room are wasted and unable to properly close. 01 A-class fire door leading from main corridor to engine room does not close properly. - 74 SOLAS (04) II-2/9.1.3 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2021
Resolved 10 October 2021
Resolution: The closure rate was adjusted for the door mechanism and all doors were tested in the presence of the attending RO.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 October 2021 Resolved
07126 - Oil Accumulation in Engine Room - Means shall be provided to control leaks of flammable liquids. PSCO observed fuel/lube oil leaks on #3 and #4 cylinders on the main engine. - 74 SOLAS (04) II-2/4.1.1 - 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2021
Resolved 10 October 2021
Resolution: The injectors and attached fuel lines were opened up, cleaned, and reassembled. No leakages observed during RO attendance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 October 2021 Resolved
13108 - Operation of Machinery - It shall be possible to control the auxiliary machinery, essential for the propulsion and safety of the ship, at or near the machinery concerned. The local control panel for the #2 boiler is inoperational. - 74 SOLAS (04) II-1/31.5.5 - 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2021
Resolved 10 October 2021
Resolution: A new locking mechanism was fabricated and the panel is now functional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 October 2021 Resolved
13199 - Other (Machinery) - Terminations and joints and all conductors shall be so made to retain the original electrical properties of the cable. The grounding wire on the #1 blower is frayed and not connected. - 74 SOLAS (04) II-1/45.5.6 - 10c
Action required: 10 - Deficiency Rectified
Due 9 October 2021
Resolved 9 October 2021
Resolution: Vessel replaced grounding wire and connected it to the system.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 23 August 2017 Resolved
The machinery, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any dangers to persons on board. The main engine oil pressure regulating valve was leaking diesel fuel. 74SOLAS (04cons) II-1/36.1
Action required: 705 - Other - as specified
Due 6 September 2017
Resolved 28 August 2017
Resolution: Recieved class report.
Operations/Management › Pollution › Quality of Fuel Oil
Issued 25 November 2016 Resolved
Per Policy Letter CG-CVC 12-04 vessel shall submit a non-availability report IAW MARPOL Annex VI Regulation 18.
Action required: 705 - Other - as specified
Due 14 December 2016
Resolved 29 November 2016
Resolution: Requested documentation was provided per Policy Letter CG-CVC 12-04. non-availability report IAW MARPOL Annex VI Regulation 18 uploaded.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 24 August 2016 Resolved
Action: 17ac Cite: 74 SOLAS (Cons. Ed. 2014) II-1/44.2 Each machinery generating set arranged automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. Emergency genorator only has manual means of start.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2016
Resolved 30 August 2016
Resolution: See attached Class Survey.

Ownership record