MEDI BANGKOK

MEDI BANGKOK is a 2006 freight ship. The Coast Guard has recorded 4 inspections since 2016, most recently in July 2019, along with 6 deficiencies.

Records from 2016 to 2019. Most recent: inspection, 1 July 2019.

Built
2006
Last inspected
1 July 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 July 2019
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9377688
927500
Flag
MARSHALL ISLANDS
Maury page id
psix-927500

Documentation record

Tonnage as PSIX records it29986 - Convention (Subpart B), Gross Ton
18486 - Convention (Subpart B), Net Ton
53466 - Dead Weight, Ton
61965 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

1 July 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6732670
23 May 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6679558
22 March 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097348
27 August 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5974289

Deficiency record · 6

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019 Resolved
Multiple cracks were observed on the guard rails in vicinity of cargo holds 2 and 4 on the Port side and cargo holdes 1 and 2 on the Starboard side. 50ac ICLL 25.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Received, reviewed and accepted Class NK report and documentation of repairs from vessel master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2019 Resolved
Multiple leaks and associated corrosion observed on main engine air scavenging system. 50ac, 74SOLAS(04)II-1/3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Received, reviewed and accepted Class NK report and documentation of repairs from vessel master.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 23 May 2019 Resolved
Corrosion and leaking observed on the bottom of the calorifier unit in the ships air condition room. 50ac, 74SOLAS(14)I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Received, reviewed and accepted Class NK report and documentation of repairs from vessel master.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 May 2019 Resolved
Fire detection and fire alarm systems shall be kept in good working order as to ensure their required performance if a fire occurs. The flame detectors over the ships generators were found covered in dust. 10c, 74SOLAS(09)II-2/14.2.2
Action required: 10 - Deficiency Rectified
Resolved 23 May 2019
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 22 March 2017 Resolved
1499 - Suitable pressure relief arrangements shall be provided for all systems. Number one air tank's fusible plug has been previously activated, causing the leakage of air from the reservoir. - 74SOLAS(04)/ II-1/34.1 - 17a,c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2017
Resolution: Received RINA class report attesting to the replacement of the plug. All was found in good working order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 March 2017 Resolved
9900 - The instructions supplied by the manufacturer must contain directions for each of the following: The type and quantity of chemicals that are required to operated the device. Vessel was not using chemicals approved by the manufacturer. - 33CFR159.57(a) - 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2017
Resolution: Received RINA class report stating the vessel had received the correct products for the MSD treatment.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.