Records from 2016 to 2019. Most recent: inspection, 1 July 2019.
Inspection history · 4
1 July 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6732670
23 May 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6679558
22 March 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097348
27 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5974289
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2019
Resolved
Multiple cracks were observed on the guard rails in vicinity of cargo holds 2 and 4 on the Port side and cargo holdes 1 and 2 on the Starboard side. 50ac ICLL 25.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Received, reviewed and accepted Class NK report and documentation of repairs from vessel master.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2019
Resolved
Multiple leaks and associated corrosion observed on main engine air scavenging system. 50ac, 74SOLAS(04)II-1/3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Received, reviewed and accepted Class NK report and documentation of repairs from vessel master.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 23 May 2019
Resolved
Corrosion and leaking observed on the bottom of the calorifier unit in the ships air condition room. 50ac, 74SOLAS(14)I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Received, reviewed and accepted Class NK report and documentation of repairs from vessel master.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 May 2019
Resolved
Fire detection and fire alarm systems shall be kept in good working order as to ensure their required performance if a fire occurs. The flame detectors over the ships generators were found covered in dust. 10c, 74SOLAS(09)II-2/14.2.2
Action required: 10 - Deficiency Rectified
Resolved 23 May 2019
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 22 March 2017
Resolved
1499 - Suitable pressure relief arrangements shall be provided for all systems. Number one air tank's fusible plug has been previously activated, causing the leakage of air from the reservoir. - 74SOLAS(04)/ II-1/34.1 - 17a,c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2017
Resolution: Received RINA class report attesting to the replacement of the plug. All was found in good working order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 22 March 2017
Resolved
9900 - The instructions supplied by the manufacturer must contain directions for each of the following: The type and quantity of chemicals that are required to operated the device. Vessel was not using chemicals approved by the manufacturer. - 33CFR159.57(a) - 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 April 2017
Resolution: Received RINA class report stating the vessel had received the correct products for the MSD treatment.