MAURY USCG vessel records Sign in
← All vessels

Y GEMINI

Y GEMINI is a 2007 tank ship. The Coast Guard has recorded 23 inspections since 2007, most recently in November 2022, along with 6 deficiencies and 3 operational controls.

Records from 2007 to 2022. Most recent: inspection, 23 November 2022.

Built
2007
Last inspected
23 November 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9327463 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
927620
Flag
LIBERIA
—
Maury page id
psix-927620

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (2007–2022)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it27916 - Convention (Subpart B), Gross Ton
13081 - Convention (Subpart B), Net Ton
47823 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

23 November 2022 Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7596714
17 November 2022 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7596338
16 November 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7595526
10 November 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592636
10 November 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7592668
5 November 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7589649
13 November 2021 MARPOL Annex VI Survey · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7350076
19 August 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7291436
27 January 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7131486
22 January 2021 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7128763
20 January 2021 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7128378
5 November 2020 COC-CHEM & TVE Renew · MARPOL Annex VI Survey · PSC B · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7090084
26 March 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6931752
22 October 2019 Administrative Inspection · ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6837203
20 October 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6564870
16 December 2015 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5782687
23 December 2009 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · COC-CHEM Renew
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3652472
14 October 2008 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3344452
11 August 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3295425
5 August 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3290469
7 April 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3178916
15 October 2007 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3077089
12 October 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3078842

Deficiency record · 6

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 January 2021 Resolved
A self-contained emergency source of electrical power shall be provided. The vessel reported that their emergency generator is non-operational due to a failure of the generator's air circuit breaker. 74SOLAS(04) II-1/43.1.1, 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2021
Resolution: Service technicians were able to make repairs to the emergency generator and switchboard. Operational test were conducted, sat. Class report attached, lifted PTD.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 22 October 2019 Resolved
The stowage space shall be... cell-divided in order to avoid shifting of the bottles at sea. The ships cargo sample locker had annex II cargoes(labeled PME) in a part of the stowage locker that was not cell divided. Some cargo residues were observed in this portion of the sample locker as objective evidence of shifting occurred.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2019
Resolution: Received, reviewed and accepted proper documentation from vessels master stating the deficiency was rectified. The vessels cargo sample locker stowage space was cleaned, repainted and adjustable cell divided spaces built.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 December 2015 Resolved
2035-Ships shall be subdivided into spaces by thermal and structual subdivisions having due regard to fire risks. PSCO observed an open through hole penetration on the A-60 fire boundary between crew changing room and engine room. SOLAS(09)II-2 Reg 9. Written to Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 February 2016
Resolved 23 October 2018
Resolution: Received [name withheld] attesting to repairs of the fire boundary.
Communications › Radio Communications › EPIRB
Issued 23 December 2009 Resolved
Hydrostatic release unit on EPIRB is designated for a liferaft. Vessel must replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 December 2009
Resolution: Received class survey report attesting to replacemetn of hydro.
Construction/Loadline › Markings › Summer Load Line
Issued 14 October 2008 Resolved
Vessel has been issued two loadline under the ICCL, Both of which are currently being displayed. Vessel to confirm the correct loadline and paint/cover the loadline not in use
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 29 October 2008
Resolution: Received attached class survey clearing def
Fire Fighting › Firemans Outfit › Helmet
Issued 15 October 2007 Resolved
Fire fighter's outfits do not comply with the fire safety systems code. The fire fighter's helmets and flash gear do not protect their face and neck from the heat radiating from the fire IAW FSSC Ch3.2.1.1.1 SOLAS 2004 Cons. Ch II-2 Reg 10.10.1
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 31 October 2007
Resolution: Received e-mail from the vessel''s master showing the proper fire fighting helmets on board via electronic picture.

Ownership record