MAURY USCG vessel records
← All vessels

CARNIVAL MAGIC

CARNIVAL MAGIC is a 2011 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 2016, most recently in January 2026, along with 43 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 10 January 2026.

Built
2011
Last inspected
10 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9378486
927918
Flag
PANAMA
Maury page id
psix-927918

Inspections, by type

…with no type recorded26
Years with a record 11 calendar years (2016–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it113529 - Regulatory (Subpart C or D), Net Ton
128048 - Convention (Subpart B), Gross Ton
113529 - Convention (Subpart B), Net Ton
13814 - Dead Weight, Ton
62789 - Displacement, Ton
128048 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 64

10 January 2026 COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8291411
31 July 2025 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8207586
13 July 2025 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8178953
11 January 2025 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8060650
14 July 2024 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7955975
18 February 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7882903
13 January 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7847820
14 October 2023 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7808445
11 July 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7744488
10 July 2023 COC-CVE Annual · PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7738271
10 May 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7685178
3 February 2023 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7631792
24 January 2023 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7626373
25 September 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571198
3 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7524068
20 July 2022 COC-CVE Annual · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7512044
7 July 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7518630
5 July 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7517730
29 June 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7490705
21 June 2022 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7483849
26 May 2022 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7459676
21 January 2022 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7383629
26 July 2021 COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7231457
5 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935671
12 October 2019 ISPS III Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6832446
17 March 2019 Ballast Water Examination · ISPS II Exam · COC-CVE Annual · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6643225
11 March 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6640183
10 February 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6623250
19 September 2018 Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6544296
8 September 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6535636
18 August 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6518460
16 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6448098
7 April 2018 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6399269
31 March 2018 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6382381
10 February 2018 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6360186
9 December 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6521546
29 October 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6321148
14 October 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6291835
30 September 2017 Administrative Inspection · ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6276631
3 September 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6297768
19 August 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6451352
17 June 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6220372
19 May 2017 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6150235
25 April 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6138275
15 April 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6282054
12 April 2017 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6122949
11 March 2017 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6272529
1 March 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6094837
11 January 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6071788
3 January 2017 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6072054
13 October 2016 Administrative Inspection · COC-CVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6021522
8 October 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6137426
17 September 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6007013
3 September 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5995269
13 August 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5973658
29 June 2016 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5923906
28 June 2016 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5923122
27 June 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6036649
25 June 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5922439
3 June 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5896527
2 June 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5946040
1 May 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5886776
17 April 2016 COC-CVE Quarterly · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5851394
10 January 2016 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5793960

Deficiency record · 43

07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 January 2025 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being ventilated. The means of closing shall be easily accessible as well as prominently and permanently marked and shall indicate whether the shut off is open or closed. PSCO's observed the means of closing the vetilation system at engine room forward failed to properly indicated its actual position. 74 SOLAS (20) II-I/5.2.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 11 January 2025
Resolution: RESOLVED
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 January 2024 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photo luminescent material or marked by lighting. PSCO's observed approximately 3 feet of low location lighting that was inoperable located near FSD 0.023. 74 SOLAS 20 II-2/13.3.2.5.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 13 January 2024
Resolution: Vessel repaired the unlit section on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 July 2023 Resolved
Fire zones in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. Double Leave doors did not close and latch properly, sequencing bars would not release the second leaf after first leaf closed. (0.012, 0.055, 0.083, 3.107, 4.089, 7.019, 8.018,14.004, 14.009) 74 SOLAS (20) II-2/9.4.1.1.5.12, 17c, cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2023
Resolution: Resolved on the spot, entered as a 17 to reflect severity of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 July 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. Fire doors did not close and latch properly (0.003, 0.083, 0.082, 9.019, 20.025) 74 SOLAS (20) 11-2/9.4.1.1.5.1, 17c, cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2023
Resolution: Resolved on the spot, entered as a 17 to reflect severity of deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 July 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures, remote-released sliding or power-operated does shall be equipped with an alarm that sounds at least 5 s but no more than 10 s after the door is released from the central control station and before the door begins to move and continues sounding until the door is completely closed. Fire doors did not close within the required time limit (1.023, 0.050, 14.009, 11.020, 11.018, 6.027) 74 SOLAS 20 11-2/9.4.1.1.5.10, 17c, cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2023
Resolution: Resolved on the spot, entered as a 17 to reflect severity of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2023 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The Life ring buoy light at the starboard embarkation station was inoperable. 74 SOLAS 20 111/20.2, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 July 2023 Resolved
Ships of all types shall be subdivided into spaces by thermal and structural divisions having regard to the fire risks of the spaces. Items found stowed behind the lining in the ceiling of deck 1 near elevator I, above the fixed fire supression system. 74 SOLAS 20 11-2/9.2.1, 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 July 2023 Resolved
The following functional requirements shall be met escape routes hall be maintained in a safe condition, clear of obstacles. Furniture in stairway enclosures shall be limited to fix seating, lockers of non-combustible materials, providing for storage for non-hazardous safety equipment may be permitted. Category 2 stairs have signs and bicycles stored in them (Dk13, 14 near spa, stair 180 and compartment 4). 74 SOLAS 20 11-2/5.3.3, 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2023 Resolved
Fire extinguishers shall be situated ready for use at easily visible places, which can be reached quickly and easily at any time in the event of a fire, and in such a way that their serviceability is not impaired by the weather, vibration or other external factors. Portable fire extinguishers shall be provided with devices which indicate whether they have been used. Portable Fire Extinguisher (galley deck 10 - 04610) on station is not charged. 74 SOLAS (20) 11-2/10.3.2.4, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 July 2023 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. The fixed fire suppression nozzle was found leaking on (deck 01 in vicinity of elevator I). Rollershutter fire door (10.091) did not close using the installed door release. 7 4 SOLAS 20 11-2/14.1.1, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 July 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Forward passenger stair way guides on deck 5 were not familiar with the emergency duties, by identifying passenger muster stations via cabin assignements. 74 SOLAS 20 111/9.2.1, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2023 Resolved
Fire hoses shall be of non-perishable material and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and the necessary couplings. Fire hose located at fire station C.04 in the engine room leaked from multiple points. 74 SOLAS (20) 11-2/10.2.3.1.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 17 July 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 January 2023 Resolved
The arrangements for the ready availability of water supply shall be in passenger ships of 1,000 gross tonnage and upwards such that at least one effective jet of water is immediately available from any hydrant in an interior location and so as to ensure the continuation of output of water by the automatic starting of one required fire pump. PSCO observed a fire main pipe ruptured causing the fire mains inoperable in MVZ 5 deck 0.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 January 2023
Resolved 5 February 2023
Resolution: Vessel completed final repairs by installing a new flange and assembly piece.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 January 2023 Resolved
Seafarers employed or engaged in any capacity on board ship on the business of that ship as part of the ship's complement with designated safety duties in operation of the ship shall, receive appropriate approved basic training in, fire prevention and fire fighting as set out in table A-VI/1-2. PSCO observed multiple crew members unfamiliar with basic firefighting procedures and ability to identify location and utilize fire extinguishers, to include stairway guides, galley personnel and hotel staff.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 February 2023
Resolved 5 February 2023
Resolution: PSCO attended the vessel on its return to port, and conducted qustioning of crew members and found all crew knowledge and retraining satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 January 2023 Resolved
The level of knowledge of the subjects listed in column 2 of the table A-VI/2-1 shall be sufficient to enable the candidate to launch and take charge of a survival craft or rescue boat in emergency situations. PSCO observed the commander of lifeboat #17 did not know what instructions to give the crew for lowering lifeboat and starboard life raft lowering team failed to demonstrate life raft lowering procedures.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 February 2023
Resolved 5 February 2023
Resolution: PSCO attended the vessel on its return to port, and conducted qustioning of crew members and found all crew knowledge and retraining satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 January 2023 Resolved
The following functional requirements shall be met escape routes shall be maintained in safe condition, clear of obstacles. PSCO observed multiple pallets of provisions that were delivered prior to previous voyage, obstructing means of escape and egress points from I-95.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 28 January 2023
Resolution: Means of escape were cleared.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 July 2022 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. The library adjacent to the mid-restaurant upper deck lacks means of quick release. 74 SOLAS 20 11-2/13.3.2.6.2, 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2022
Resolved 3 August 2022
Resolution: Resolved via satisfactory class report, see documents tab to review.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 July 2022 Resolved
Illustrations and instructions in appropriate languages shall be posted in passenger cabins and be conspicuously displayed at muster stations. Muster station D4 (aft) was missing required emergency instructions. Rectified on the spot. 74 SOLAS (20) 111/8.4, 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 July 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire pro~ection, including fire-resisting divisions and protection of openings and penetrations in these division. Witnessed discrepancies on the following FSDs: C-006, C-019, 1.026, 4.094, 6.040, 6.049. Rectified on the spot. 74 SOLAS 20 11-2/14.2.1, 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2022
Resolution: All doors were repaired on the spot, satisfactory operation was witnessed by attending examiners.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 20 July 2022 Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. Upon deployment of liferaft, crew deployed liferaft to point of inflation, but the position of the raft would not have allowed for embarkation of passengers. When prompted to fix position, crew was initially unable until receiving further training. 74 SOLAS 20 111/19.3.1, 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 July 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lighted life buoy located on STBD bow, deck 11 , was found inoperable. Rectified on the spot. 74 SOLAS 20 111/20.2, 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2022
Resolution: Replaced on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 July 2022 Resolved
Escape routes signs and fire equipment location markings shall be of photo luminescent material or marked by lighting. Emergency escape sign outside of Cabin 7359 was found extinguished. Rectified on the spot. 74 SOLAS 2011-2/13, 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2022
Resolution: Lightbulb replaced on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 July 2022 Resolved
Escape routes shall be maintained in clear condition, free of obstacles. The Vibe Nightclub had paintings arranged in a manner that obstructed the second escape from the space. Corrected on the spot. 74 SOLAS 20 11-2/13, 10c.
Action required: 10 - Deficiency Rectified
Resolved 26 July 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 January 2022 Resolved
SOLAS 09 II-2/9.4.1.1.2 The construction of doors and frames in "A" Class divisions, with the means of securing them when closed, shall provide resistance to fire as well as the passage of smoke and flame equivalent to the bulkheads in which the doors are situated. FSD 4.053, FSD 4.045, and FSD 7.017 did not close as designed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 26 July 2021 Resolved
11134 - Operation of Life Saving Appliances - Every crew member with assigned emergency duties shall be familiar with the duties before the voyage begins. Various crew members in passenger evacuation positions and life boat crews were found to be unfamiliar with their emergency duties. 74 SOLAS 20 III/9.2.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 26 July 2021
Resolved 27 July 2021
Resolution: Training was completed of all crew to the satisfaction of the Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 July 2021 Resolved
07110 - Fire Fighting Equipment - A fixed fire-extinguishing system may be pressure water-spraying fire-extinguishing systems complying with the provisions of the Fire Safety Systems Code. Any required automatic sprinkler...shall be capable of immediate operation at all times. 03 Hi-Fog nozzles bulbs were drained of fluid in Freezer Room 22 on Deck 0. 74 SOLAS 09 II-2/10.4.1.1.3, FSS CODE 9.2.5.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 July 2021
Resolved 26 July 2021
Resolution: Fog nozzels were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 July 2021 Resolved
09209 - Electrical - Electrical installations shall be such that the safety of passengers. Crew, and ship from electrical hazards will be ensured. PSCOs witnessed exposed conductor aft of the fwd. life rafts on the stbd side of the vessel and a junction box was open, exposing wires in the stbd engine of lifeboat 5. 74 SOLAS 04 II-1/40.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 26 July 2021
Resolved 26 July 2021
Resolution: Electrical hazards were repaird.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 July 2021 Resolved
07103 - Division - Fire integrity of bulkheads and decks shall meet the minimum integrity for table 9.1 and 9.2. PSCOs witnessed structural fire protection in the AC station 1.1 and stairwell Deck 0 Stair 30 that did not meet the minimum integrity of an A-60 boundary. 74 SOLAS 09 II-2/9.2.2.3.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 26 July 2021
Resolved 26 July 2021
Resolution: Bulkhead was repaird.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 July 2021 Resolved
11129 - Operational readiness of lifesaving appliance - Before the ship leaves port and at all times during the voyage, all life-saving appliance shall be in working order and ready for immediate use. PSCOs observed multiple life boats with several inches of water in the bilges of the engine compartments. Vessel’s crew was unable to demonstrate the removal of the bilge water through installed electrical bilge pumps. 74 SOLAS 20 III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 July 2021
Resolved 26 July 2021
Resolution: Training was conducted on boat crews and boats were made ready.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2021 Resolved
07199 - Fire Safety - Means shall be provided to prevent the ignition of combustible materials or flammable liquids. The ignitability of combustible materials shall be restricted. PSCOs observe multiple bottles of flammable liquids not stored in the proper flammable locker in the SPA. 74 SOLAS 09 II-2/4.1.3
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 26 July 2021
Resolved 26 July 2021
Resolution: All flammable liquids were stored properly
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 October 2019 Resolved
FIRE DOORS IN MAIN VERTICAL ZONE BULKHEADS, GALLEY BOUNDARIES, AND STAIRWAY ENCLOSURES... SHALL BE SELF CLOSING. F.S.D;S 11.034 AND 14.020 WOULD NOT FULLY CLOSE, COMPROMISING THE "A" CLASS BOUNDARY. 74SOLAS(14CONS.)II-2/ 9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 October 2019
Resolved 12 October 2019
Resolution: SHIP'S CREW PERFORMED MAINTENANCE TO ENSURE THE AFOREMENTIONED F.S.D's WERE CLOSEING PROPERLY.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2019 Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS TO NOT CAUSE UNJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER. ELECTRICAL PUMP IN WATER GAMES MACHINERY SPACE WAS NOT PROPERLY GROUNDED. 74SOLAS(04 CONS.)II-1/ 45.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 October 2019
Resolved 12 October 2019
Resolution: GROUNDING WIRE WAS PRESENT BUT NOT PROPERLY INSTALLED, SHIPS CREW RECTIFIED PRIOR TO INSPECTION TEAM'S DEPARTURE.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 March 2019 Resolved
Rescue boats shall have sufficient mobility and manoeuverability in a seaway to enable persons to be retrieved from the water. Rescue boat #2 was found to be inoperable, due to clogged filter. 14SOLAS III/22.2.1
Action required: 10 - Deficiency Rectified
Due 17 March 2019
Resolved 17 March 2019
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 March 2019 Resolved
Arrangements shall be made to ensure immediate availability of a supply of water from the fire main. Fire Hydrant located in the incinerator room (hydrant C27) did not receive immediate pressure upon opening the valve. 04SOLAS II-2/19.3.1.1
Action required: 10 - Deficiency Rectified
Due 17 March 2019
Resolved 17 March 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2019 Resolved
Auxiliary machinery spaces which do not contain machinery having a pressure lubricatiion system and where storage of combustibles is prohibited is designated as a category 10 space. Combustible material was found in A.C. station 1.1 04SOLAS II-2/9.2.2.3.2(10)
Action required: 10 - Deficiency Rectified
Resolved 17 March 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 March 2019 Resolved
Every crew member with assigned emergency duties shall be familiar with their duties before the voyage begins. Multiple crew members on vessel were not aware of their duties. During the fire and abandon ship drill, stairwell guides unable to provide consistent answers. Galley crew unaware of Hi-Fog operation. 14SOLAS III/19.7.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 March 2019
Resolution: Class submitted statement attesting to the satisfactory correction of the deficiency after training records provided.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 10 February 2019 Resolved
While pierside, appropriate onshore reception facilities for graywater muct be used unless the vessel treats graywater in the approved manner. While operating within 3 nm from shore, discharges of graywater are prohibited. Vessel failed to utilize approved reception facilities and inadvertently discharged graywater through ballast system into Port of Miami while pierside. VGP 5.1.1.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 February 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2018 Resolved
11117 - Lifebuoys - Lifebuoys shall comply with the requirements of paragraph 2.1.1 of the code. 03 Lifebuoys were found to be unservicable. 74 SOLAS 14 Cons CH III Reg 7.1.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 October 2018
Resolution: Vessel replaced lifebuoys to the satisfaction of class.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 September 2018 Resolved
07108 - Ready availability of fire fighting equipment - Firefighting systems and appliances shall be ready for immediate use. Found firelocker 11.16 inaccessible and 01 fire hose not connected to fire main. 74 SOLAS 09 cons Ch II-2 Reg 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 22 September 2018
Resolution: Fire Fighting appliances were brought into a ready condition prior to departure.
Lifesaving › Rescue Boat › Construction
Issued 28 June 2016 Resolved
Damaged Rescue Boat shall be replaced or plan from Class for permenant repair.
Action required: 705 - Other - as specified
Due 10 January 2017
Resolved 11 January 2017
Resolution: Ship's Manager provided documentation from Class Surveyor that damaged rescue boat has been repaired. Full term PSSC has been re-issued with an expiration of 28Apr2017.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 28 June 2016 Resolved
Class is to designate life boat as itrem rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2016
Resolution: Class Report and Intrem PSSC docs provided.
Lifesaving › Rescue Boat › Construction
Issued 28 June 2016 Resolved
Falls on Stbd Rescue Boat to be surveyed by Class.
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 5 July 2016
Resolution: Received tech report and Sector San Juan tested the falls with Resecue Boat on 6/29.
Lifesaving › Rescue Boat › Construction
Issued 28 June 2016 Resolved
Class to provide causal analysis for fall failure.
Action required: 705 - Other - as specified
Due 17 February 2017
Resolved 27 February 2017
Resolution: Received causal anaylsis report from CCL, report uploaded to MISLE.

Ownership record