Records from 2000 to 2019. Most recent: inspection, 5 August 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
5 August 2019
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6773378
17 September 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6542030
12 April 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6392523
20 October 2017
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6291697
28 June 2017
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6188518
23 May 2017
Excursion Permit
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6153355
19 September 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6004385
24 May 2016
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5885203
5 May 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5869895
18 February 2016
Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5817290
19 October 2015
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5745711
25 September 2015
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5733314
28 June 2012
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4359285
14 February 2012
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4244229
13 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4207383
26 September 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4154664
13 September 2010
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3849003
25 February 2010
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3686062
29 July 2009
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3549307
21 July 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3274819
2 January 2008
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3123504
25 June 2007
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2973051
16 August 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2749576
31 May 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2665805
25 August 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2474096
19 August 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2177480
31 March 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2034905
17 July 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1850204
12 July 2002
Administrative Inspection
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1645069
18 June 2002
Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1632394
24 May 2002
Inclining Experiment · Initial Certification · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1625619
20 March 2001
Inclining Experiment
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1070241
26 June 2000
Plan Review "T" Boat · Construction Oversight
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376254
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 June 2017
Resolved
Pre-engineered system did not initially shutdown engine. It was determined that voltage had not built up enough to actuate selanoid. Required to trouble shoot operation of fir buoy shutdown and provide report.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 14 July 2017
Resolution: Vessel rep replaced battery bank and solenoid. Engine shutdown and override start tested satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 19 September 2016
Resolved
Propulsion shaft packing gland was found to be leaking excessively with a solid stream of water. Issued requirement to make repairs to shaft packing to reduce water ingress.
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 3 October 2016
Resolution: Inspected shaft packing gland. New packing was installed and was found to be free of leaks.
Operations/Management › Drills/Instruction › Fire
Issued 25 September 2015
Resolved
Conduct man overboard and fire drills in the presence of a Coast Guard Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2016
Resolution: Conducted man overboard and fire fighting drills.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 September 2015
Resolved
Replace ring buoy lifeline.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2016
Resolution: Vessel rep renewed ring buoy lifeline.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 September 2015
Resolved
Replace Fireboy manual pull T-handle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2016
Resolution: Fireboy T-handle was replaced with a new one.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 September 2015
Resolved
Repair main engine exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 September 2016
Resolution: Main engine exhaust bellow was replaced in-kind.
Documentation › Certificates/Documents › Stability Letter
Issued 13 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THEREFORE LIMITED TO: 45 PERSONS(PASSENGERS AND CREW)
Due 1 June 2012
Resolved 28 June 2012
Resolution: Operator is awaiting Stability Letter from MSC.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 September 2011
Resolved
Automatic shut-down for pre-engineered fixed fire fighting system is inoperable. Repair automatic shut-down prior to the carriage of passengers.
Action required: 705 - Other - as specified
Due 1 October 2011
Resolved 7 October 2011
Resolution: Starting solenoid and wiring was replaced. System was tested. Alll sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 September 2010
Resolved
Fixed fire extinguishing system did not automatically shut down the main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 29 September 2010
Resolution: Fire boy tech discovered that the cable between the solenoid and the fuel pump was to short preventing the engine from shutting down. The tech replaced the cable and tested the system shut down, all sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 September 2010
Resolved
The remote fuel shut off cable is frozen and the valve won't operate properly. Repair or replace the cable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2010
Resolved 15 September 2010
Resolution: Vessels owner disassembled the cable, cleaned and replaced. Witnessed and tested the remote shut down. Test sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 14 September 2010
Resolved
Conduct fire and man overboard drills in the presents of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2010
Resolved 15 September 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 14 September 2010
Resolved
Replace the wasted 60 feet of life line for the ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 15 September 2010
Resolution: Life line replaced with new line.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 September 2010
Resolved
Replace the outdated navigation charts with updated charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 15 September 2010
Resolution: All charts replaced with 2010 editions.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 September 2010
Resolved
Replace the inop compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 15 September 2010
Resolution: Compass light replace and operating properly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2010
Resolved
The stern light does not stay in place. Properly mount the light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2010
Resolved 15 September 2010
Resolution: Light is properly mounted and witnessed operation of the light. Test sat.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 21 July 2008
Resolved
Renew expired Hydrostatic Release Units on port and stbd life rafts. Vessel operates within Boston Harbor.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 25 July 2008
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 21 July 2008
Resolved
Properly adjust/tighten shaft packing gland.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 25 July 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 July 2008
Resolved
Properly cover open breaker spaces on swithboard.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 25 July 2008
Resolution: Corrected
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 July 2008
Resolved
Properly insulate engine exhaust pipe where it passes through plywood deck in head. Existing since new construction, pipe does not become "wet" until obove the deck.
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 25 July 2008
Resolution: Corrected
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 25 June 2007
Resolved
Provide communications act safety radiotelephony certificate.
Due 2 July 2007
Resolved 28 June 2007
Resolution: Provided sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 June 2007
Resolved
repair inop engine shutdown.
Due 25 June 2007
Resolved 28 June 2007
Resolution: Repaired and tested sat.
Lifesaving › Hand Flares › Quantity
Issued 25 August 2005
Resolved
Provide proper amount of siganaling flares for route intended.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2005
Resolved 25 August 2005
Resolution: all required flares on board.
Communications › Radio Communications › EPIRB
Issued 25 August 2005
Resolved
Provide hyrostatic release for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2005
Resolved 25 August 2005
Resolution: Provided sat.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 August 2005
Resolved
Provide light list.
Due 8 September 2005
Resolved 25 August 2005
Resolution: Provided sat light list.
Communications › Radio Communications › EPIRB
Issued 17 July 2003
Resolved
Vessel is limited to Lakes, Bays, and Sounds route until registration of the EPIRB is provided.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 22 July 2003
Resolution: EPIRB is registered.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 July 2003
Resolved
Prove proper operation of high level bilge alarm system.
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 22 July 2003
Resolution: Proved proper operation of high level bilge alarm system.
Engineering › Steering Gear System › Linkage
Issued 17 July 2003
Resolved
Replace missing nut on shaft packing.
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 22 July 2003
Resolution: Replaced missing nut on shaft packing.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 17 July 2003
Resolved
Prove proper servicing of fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 22 July 2003
Resolution: Proved proper servicing of fixed fire extinguishing system.
Electrical › Electric Supply System (service)
Issued 24 May 2002
Resolved
Provide one copy of drawing: Battery system, isolator, charger installation LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 29 January 2003
Communications › Alarms/Indicators
Issued 24 May 2002
Resolved
Provide one copy of drawing: Murphy Series Selectronic Alarm Annuniciator LEGACY COMPONENT DESC: General Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 29 January 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 May 2002
Resolved
Provide 3 copies of drawing: Location of safety equipment including fire extinguishers, life rafts, PFD storage, life ring, EPIRB, and emergency steering tiller.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 29 January 2003