Records from 2016 to 2025. Most recent: inspection, 1 December 2025.
Inspection history · 11
1 December 2025
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8269746
29 October 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8012392
4 October 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7791750
6 October 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7574118
24 September 2021
DAPI Audit · Drydock Exam · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7319798
1 October 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7065281
24 September 2019
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6815257
27 September 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6549482
28 September 2017
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6276854
13 September 2016
Internal Structural Exam · DAPI Audit · COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5999067
5 August 2016
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5980919
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2021
Resolved
EACH ITEM OF SURVIVAL CRAFT EQUIPMENT MUST BE OF GOOD QUALITY AND EFFICIENT FOR THE PURPOSE IT IS INTENDED TO SERVE.
LIFE RING IS GASHED AND NO LONGER SERVICEABLE.
46 CFR 180.175(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 5 October 2021
Resolution: Operator purchased new life ring and replaced gashed life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2021
Resolved
A VESSEL IS INSPECTED FOR COMPLIANCE WITH THE STANDARDS REQUIRED BY THIS SUBCHAPTER. MACHINERY, EQUIPMENT, MATERIALS, AND ARRANGEMENTS NOT COVERED BY STANDARDS IN THIS SUBCHAPTER MAY BE INSPECTED IN ACCORDANCE WITH STANDARDS ACCEPTABLE TO THE COGNIZANT OCMI AS GOOD MARINE PRACTICE.
THE RETURN FUEL FLEXIBLE HOSE WAS NOT CONNECTED TO THE FUEL FILTER.
46 CFR 176.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 5 October 2021
Resolution: Operator removed return line and capped the through-tank fitting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2021
Resolved
A VESSEL IS INSPECTED FOR COMPLIANCE . . . IN ACCORDANCE WITH STANDARDS ACCEPTABLE TO THE OCMI AS GOOD MARINE PRACTICE.
THE FLEXIBLE FUEL HOSE BETWEEN THE FUEL SHUTOFF AND FUEL PUMP IS NOT CONTINUOUS.
46 CFR 176.800(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 5 October 2021
Resolution: Operator replaced with a continuous flexible hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2021
Resolved
AN ADULT LIFE JACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD THE VESSEL.
11 ADULT AND 3 CHILD SIZE LIFE JACKETS ARE PROPERLY LABELED AND IN SERVICEABLE CONDITION. VESSEL IS LIMITED TO 11 ADULT AND 3 CHILD PASSENGERS.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 30 September 2021
Resolved 5 October 2021
Resolution: Operator replaced lifejackets for a total of 16 adult persons and 2 child passengers. Total persons on board as per COI restored.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 September 2021
Resolved
THE NUMBER AND IDENTIFICATION OF THE ITEMS STOWED INSIDE, AND THEIR SIZES, MUST BE MARKED IN CLEARLY LEGIBLE LETTERS AND NUMBERS ON EACH CONTAINER.
LIFE JACKET STOWAGE NOT LABELED WITH NUMBER OF LIFE JACKETS.
46 CFR 185.604(f)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 5 October 2021
Resolution: Operator labeled life jacket stowage with total number stowed in each area.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2019
Resolved
Marine inspector discovered retroreflective material was not approved IAW 46 CFR 164.018 and wasted. Retro-reflective material will need to be replaced.
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 30 September 2019
Resolution: Owner replaced retroreflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2019
Resolved
Marine inspector discovered life jackets to be unserviceable IAW 46 CFR 180.71. Replace unserviceable lifejackets.
Action required: 10 - Deficiency Rectified
Due 10 October 2019
Resolved 30 September 2019
Resolution: Owner replaced unserviceable lifejackets
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 September 2018
Resolved
All fuel tanks must be electrically bonded to a common ground. MI observed ungrounded fuel tank. Ground. - 46CFR182.440(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2018
Resolved 19 October 2018
Resolution: Vessel owner bonded fuel tank to hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2018
Resolved
Flexible hose designated for use with hose clamps may be installed with two clamps at both ends of the hose. MI observed missing hose clamps at fuel exhaust lines. - 46CFR182.715(e)(3)(v)(B)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2018
Resolved 19 October 2018
Resolution: Vessel owner double hose clamped fuel exhaust line.
Lifesaving › Hand Flares › Expired
Issued 28 September 2017
Resolved
Provide proper type and amount of distress flares iaw 46CFR180.68(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2017
Resolution: Purchased new distress signals.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 September 2017
Resolved
Provide replacement for first aid kit iaw 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 12 October 2017
Resolution: Purchased new first aid kit.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 September 2016
Resolved
Vessel's rails and courses are spaced at 12" intervals. Spacing of rails and courses on excursion vessels is required to be no greater than 4". Submit proposal for satisfying requirement to marine inspector IAW 46 CFR 177.900 (g) (1)
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 17 October 2017
Resolution: District determined the hand rails are acceptable.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 27 September 2016
Resolved
Vessel does not have the A-II fire extinguisher for the accommodation space as required by Table 181.500(a) of 46 CFR. Provide one A-II fire extinguisher for the accommodation space IAW 46 CFR 181.500
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 17 October 2017
Engineering › Fuel Oil Service System › Hose
Issued 13 September 2016
Resolved
Remove and replace fuel hose with approved type on fuel delivery system between tank and filter IAW 46 CFR 182.720(e)(3)(v)(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 13 September 2016
Resolution: O/o purchased new CG type A1/B1 hose
Documentation › Certificates/Documents › Stability Letter
Issued 13 September 2016
Resolved
Retain original stability letter on board vessel or official copy IAW 46 CFR 176.306
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 13 September 2016
Resolution: O/o got stability letter from office.