Records from 2016 to 2026. Most recent: inspection, 4 May 2026.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 11.0 ft × 3.3 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE SHIPBUILDING CORP · SALISBURY, MD, UNITED STATES · built 2008
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portSALISBURY, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
4 May 2026
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8357384
5 May 2025
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8130229
6 May 2024
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7908516
4 May 2023
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7680779
2 May 2022
COI Inspection · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7442240
8 May 2019
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6685784
10 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6411187
16 May 2017
DAPI Audit · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6143976
16 May 2016
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5880614
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 5 May 2025
Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high-water level. Vessels audible bilge alarm was non-operational.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 8 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024
Resolved
Child lifejackets must be separated from adult lifejackets. A label must be on the vessel indicating where the child lifejackets are stored.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: Jackets seperated and labelled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2024
Resolved
Lower housing of fuel filters are plastic. Replace with metal filters or something in compliance with 46CFR182.455
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: Lower housings replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2024
Resolved
Port running light not working. Repair/replace as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: Light repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2024
Resolved
Bilge alarm not working. Repair/ replace as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: Alarm fixed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 May 2024
Resolved
Digital Selective Calling (DSC) not hooked up on VHF radio. Connect DSC and test to the satisfaction of Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: New radio with internal GPS installed. MMSI programmed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2024
Resolved
Vessel stability letter has maximum draft requirements. Put loading marks on vessel to comply with stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: Draft marks provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 May 2024
Resolved
Vessel could not provide FCC Safety Radio Certificate. Provide certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2024
Resolved 10 May 2024
Resolution: Certificate provided.