LA CROSSE QUEEN VII

LA CROSSE QUEEN VII is a 2008 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2007, most recently in July 2026, along with 5 deficiencies and 1 casualty investigation in 2022.

Records from 2007 to 2026. Most recent: inspection, 7 July 2026.

Built
2008
Last inspected
7 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

928993
Flag
UNITED STATES
—
Maury page id
psix-928993

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (2007–2026)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 19.8 ft × 4.5 ft
Registered tonnagegross 52 / net 37
ITC dimensions (L × B × D)61.0 ft × 19.8 ft × 4.5 ft
ITC tonnageNot recorded
BuilderMID-CITY STEEL INC · LACROSSE, WI, UNITED STATES · built 2008
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLA CROSSE, WI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

7 July 2026 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8432524
23 June 2025 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8162119
25 June 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7942777
15 June 2023 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7715122
12 July 2022 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7476254
13 June 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7476260
20 May 2022 Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7459697
9 April 2022 Drydock Extension
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7428614
24 October 2021 Drydock Extension
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7339819
8 July 2021 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7249900
28 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7019983
8 July 2019 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6743069
24 April 2018 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6374295
18 July 2017 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6177910
4 November 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6036604
3 June 2016 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5898814
26 June 2014 Type not recorded
No type recorded · USCG Heartland District (dwb) · USCG Heartland District (CGD-H) · Activity 4900812
12 June 2014 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4890109
23 July 2012 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4387737
17 May 2012 Type not recorded
No type recorded · USCG Heartland District (dwb) · USCG Heartland District (CGD-H) · Activity 4313716
26 July 2011 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4094088
1 July 2009 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3520435
10 November 2007 Initial Construction-Excluding Oversight · Welding Related Inspections Qualification Testing · Simplified Stability Test · Plan Review "T" Boat · Initial Certification
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3195466

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 June 2024 Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. Voltmeter on bridge was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 26 August 2024
Resolution: Volt meters replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 June 2022 Resolved
01 outlet cover needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 June 2022
Resolution: cover replaced
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 July 2021 Resolved
failed drill due to lack of communication amongst crew, lack of sound signals, lack of second deckhand wearing life jacket.
Action required: 10 - Deficiency Rectified
Resolved 8 July 2021
Resolution: education given and sat MOB conducted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2014 Resolved
Make operational audible bilge alarm at operating station.
Due 19 June 2014
Resolved 18 June 2014
Resolution: Received email attesting to the repair and testing of bilge alarm.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 June 2014 Resolved
Stencil ring buoys
Due 12 July 2014
Resolved 18 June 2014
Resolution: Ring buoys stenciled as required.

Casualty record · 1

20 May 2022Routine · role: Involved in a Marine Casualty · activity 7459697
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.