MAURY USCG vessel records Sign in
← All vessels

CORAL MILLEPORA

CORAL MILLEPORA is a tank ship. The Coast Guard has recorded 3 inspections since 2007, most recently in November 2008, along with 3 deficiencies and 3 operational controls.

Records from 2007 to 2008. Most recent: operational control imposed, 28 November 2008.

Built
Not recorded
Last inspected
28 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9129392 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
929001
Flag
NETHERLANDS
—
Maury page id
psix-929001

Inspections, by type

…with no type recorded1
Years with a record 2 calendar years (2007–2008)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4054 - Simplified, Gross Ton
1216 - Simplified, Net Ton
7596 - Displacement, Ton
5121 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

28 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3370537
25 November 2008 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3369457
8 November 2007 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3095149

Deficiency record · 3

Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 25 November 2008 Resolved
1899 Tankers - The fixed gas detection is leaking sampled gas into the Cargo Control Room. Prior to departure the vessel is required to repair the system and have a certified technician certify the satisfactory operation of the Gas Detection System. IGC Code (1993 ED) CH 13/Reg 13.6
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2008
Resolution: Received Class Report attesting to the proper operation of the Fixed Gas Detection system.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 8 November 2007 Resolved
Vessel was unable to provide documentation that the lifeboat was launched via free fall within six months.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2007
Resolution: The vessel submitted a Class report attesting to the launch and operation of the free fall life boat and water spray system.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 8 November 2007 Resolved
Vessel was unable to calibrate and test the portable gas detector IAW manufacturers recommendation due to the fact that the span gas was expired. Vessel must replace expired span gas and calibrate, test.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 November 2007
Resolution: The vessel submitted a Class report stating the span gas to be renewed and demonstrated to attending GL surveyor within the next 60 days.

Ownership record