CHRISTINA B is a 2007 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in February 2026, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 27 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it40424 - Convention (Subpart B), Gross Ton 25482 - Convention (Subpart B), Net Ton 87763 - Displacement, Metric Ton 77053 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 7
27 February 2026PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8317435
22 February 2024PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7864849
1 October 2019Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6821427
25 January 2019Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6615224
20 November 2018Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6584255
31 August 2018Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6523090
21 December 2016Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6059248
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 21 December 2016Resolved
0720; Ship shall carry at least two fire fighting outfits. A suit shall consist of protective clothing with material to protect the skin form heat radiating from the fire and from burns and scalding by steam. PSCO found one of the fire fighting outfits with damage reflective material which could cause injury to persons wearing the suit SOLAS (09) II-2 10.20.2.1, 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 September 2018
Resolved 31 August 2018
Resolution: INSPECTED FIREFIGHTING OUTFITS DURING DRILL AND DURING EXAM ALL SAT
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 December 2016Resolved
1400; The machinery, boilers, other pressure vessels and associated piping and fittings shall be of a design an construction adequate for the service for which they are intended. Patches were found on the following: Ballast pipe to educator, on the educator, discharge pipe from fire / bilge pump, sewage processing unit is wasted at the fill pipes, 74 SOLAS (14) II-1, Reg., 26, 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 September 2018
Resolved 30 August 2018
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 21 December 2016Resolved
0725; The function of fixed fire detection system shall be periodically tested by means of equipment producing phenomena associated with incipient fires to which the detector is designed to respond. Vessel does not have proper equipment to test the water mist system, 74 SOLAS (14) II-2/7.3.2, 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 September 2018
Resolved 30 August 2018
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 21 December 2016Resolved
2510; Vessel must maintain a Bio-Fouling Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel did not have a Bio-Fouling Management Plan, 33CFR151.2050 (g) reference IMO MEPC Resolution 207 (62), 10c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2016
Resolved 21 December 2016
Resolution: Spoke with [name withheld] and Chief Engineer about Bio-Fouling documentation.