CARNIVAL LUMINOSA

CARNIVAL LUMINOSA is a 2009 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2026, along with 28 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 17 April 2026.

Built
2009
Last inspected
17 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9398905
929408
Flag
BAHAMAS, THE
Maury page id
psix-929408

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it92720 - Simplified, Gross Ton
92720 - Convention (Subpart B), Gross Ton
59465 - Simplified, Net Ton
59465 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

17 April 2026 COC-CVE Quarterly · PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8350381
30 March 2026 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8334511
4 September 2025 PSC B · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8214980
1 September 2025 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8225388
31 August 2025 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8221282
21 April 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8116472
7 March 2025 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8090056
20 September 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8006570
5 September 2024 COC-CVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7996081
4 June 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7927306
25 April 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7900795
18 April 2024 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7901518
8 April 2024 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7889669
8 April 2024 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7892143
31 August 2023 COC-CVE Annual · PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7781333
28 April 2023 PSC A · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7677142
2 December 2019 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6863702
7 February 2018 Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334384
6 February 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6350158
29 September 2016 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6001857

Deficiency record · 28

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2026 Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant catagory having the most stringent boundary requirements. PSCO observed a storage locker with approx. 20 boxes on Deck 9, adjacent to the open deck grill restaurant (cat. 7) surrounded by an open deck (cat. 5). 74 SOLAS 20 II-2/9.2.2.3.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2026
Resolved 17 April 2026
Resolution: Corrected by crew removing items following identification by marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 September 2025 Resolved
Passenger ships carring more than 36 passengers shall be equipped with an automatic sprinklet of an approved type complying with the requirements of the Fire Safety Systems Code in all control stations, accommodation and service spaces, including corridors and stairways. FSS 7.2.1.1.2 PSCO observed storage of combustible materials stored in the following locations: steward station near FD.4.6.05, locker near FD.3.2.14, steward station near FD.4.2.10, and photo equipment storage room, stored aboce line indicating water mist coverage. 74 SOLAS 20 II-2/10.6.1.1 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 4 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 September 2025 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, opening shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the diviesions in which they are fitted. PSCO observed the following FSD not closing/atlching: FD.A.4.13, FD.8.5.02, and FSD marked 10.5.04 located in the child care center. 74 SOLAS 20 II-2/9.4.1.1.1 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 4 September 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 4 September 2025 Resolved
Escape doors from public spaces that are normally latched shall be Fitted with a means of quick release. Such means shall consist of a Door-latching mechanism incorporating a device that releases the Latch upon the application of a force in the direction of escape flow. PSCO found thumb latches on exit doors in theater, FD.3.6.18. 74 SOLAS 20 II-2/13.3.2.6.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 8 September 2025
Resolution: The thumb latches were removed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 September 2025 Resolved
Where contents and use of space are such that there is a doubt that As to its classification for purposes of this regulation, or where it is Possible to assign two or more classifications to a space, it shall be Treated as a space within the relevant category having the most Stringent boundary requirements. PSCO observed storage of Combustible materials in AC machinery spaces 4.1 and 4.6. 74 SOLAS 20 II-2/9.2.2.3.2.2. 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 8 September 2025
Resolution: Combustible materials were removed from the machinery spaces.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 September 2025 Resolved
Electrical installations shall be such that: the safety of passengers, Crew and ship from electrical hazards will be ensured. PSCO Observed water leaking into multiple overhead light fixture in crew Galley deck A. 74 SOLAS 04 II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2025
Resolved 8 September 2025
Resolution: Water leaks in the crew galley overhead were secure and lighting fixtures were repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 September 2025 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. The vessel representative reported #1 Diesel generator shut down while under load. Determine cause for uncommanded shutdown and repair #1 Diesel generator. 74 SOLAS 20 II-1/31.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 16 September 2025
Resolution: Cleared. RPM sensor with loose wiring, identified as root cause.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 April 2025 Resolved
After any survey of the ship, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. Washer and dryer have been added into the bosun stores with improper electrical wiring and dryer ventilating into the space. This aleration was not approved by class. 74 SOLAS 20 I/11.b
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2025
Resolved 7 May 2025
Resolution: Per DNV the dryer has been fixed. Power wiring is connected directly, exhaust duct was installed to main exhaust. Drain line is connected to ships grew water.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 April 2025 Resolved
The load line ring, lines and letters shall be painted white or yellow on a dark background or in black on a light background. They shall also be permanently marked. The port side loadline was not painted in a contrasting color. LOAD LINE CONVENTION 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 May 2025
Resolution: According to DNV, plimsoll marks have been repainted with contrasting color.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Self-closing fire door 2.6.01 would not latch. 74 SOLAS 20 II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 April 2025 Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. B-15 door outside of Alchemy Bar won't close on deck 3, starboard side. 74 SOLAS 20 II-2/9.4.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 April 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 April 2025 Resolved
The means of escape, including stairways and exits, shall be marked by lighting of photo luminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photo luminescent material or marked by lighting. A single light on the bulkhead deck at watertight compartment 16 was found broken and covered with a metal band. 74 SOLAS II-2/13.3.2.5.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 26 April 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 April 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. X-ray equipment was found tied to the handrail in stairway enclosure 7, deck 3, main vertical zone 4. 74 SOLAS II-2/13.1.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 26 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 September 2024 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 9.1 and 9.2. Deck 3 embarkation area window seals are not currently meeting proper A60 fire ratings due to rust and breakdown. 74 SOLAS 20 II-2Reg 9.2.2.3.1 Action Taken: 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 September 2024
Resolved 20 September 2024
Resolution: Received class report attesting to rectification of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 September 2024 Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. All life saving appliances shall be fitted with retro-reflective material where it will assist in detection. Number 2 Port Side rescue boat missing proper retro-reflective tape. 74 SOLAS 20 III/34 LSA Code 1.2.2.7 Action Taken: 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 September 2024
Resolved 5 September 2024
Resolution: Retro reflected tape was applied to the port side rescue boat. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 5 September 2024 Resolved
Rescue boat launching arrangements shall be such that the rescue boat can be boarded and launched in the shortest possible time. Number 2 rescue boat port side davit was unable inoperable. 74 SOLAS 20 III/17.1 Action Taken 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 September 2024
Resolved 5 September 2024
Resolution: Ship's electrician discovered a faulty connection on the davit control switch. Connection point was cleaned and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 April 2024 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. PSCO observed on Deck A ship stores blocking low location lighting for approximately 30 ft. 74 SOLAS (2009 Cons Ed) II-2 Reg. 13.3.2.5.1 10c Code 07105
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 April 2024
Resolution: Ship's crew removed pallets of ship stores from Deck A.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 April 2024 Resolved
Safe escape routes shall be provided. Chef's office on deck 9 aft galley is not equipped with an equivalent level of safety for immediate notification for escape of crew normally employed in the space. 74 SOLAS (2020 Cons Ed) II-2 Reg. 13.1.1. 10c Code 07120
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 April 2024
Resolution: Crew removed office furniture from the room being used as chef's office, returning it to its categorization as a storage room.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 April 2024 Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed glass panels being storage under stairwell on deck 2 behind fire door 2.2.05. 74 SOLAS (2020 Cons Ed) II-2 Reg. 13 10c Code 07120
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 April 2024
Resolution: Ship's crew removed stored glass panels under forward crew stairwell on deck 2.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 April 2024 Resolved
40AC- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or the persons on board. Potable water pipes in the deck 9 Lido Restaurant overhead were found to be leaking and pooling water on overhead electrical cables and fixtures - creating an electrical shock hazard and slip/fall hazard, at the following locations: 1. Port Side buffet line around frame 90 2. Starboard side galley around frame 74 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 April 2024
Resolved 4 June 2024
Resolution: 04JUN2024: Sector Puget Sound recieved Class report 45046 attesting to repairs of piping on the Lido deck. See documents tab for more information.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 April 2024 Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. For this purpose, the following functional requirements shall be met: 1. Means of control for the air supply to the space shall be provided. The B-15 rated fire door located in deck 7, port side aft next to room 7260 has a gap in the top and side when door is fully closed, allowing daylight and air into the space. 74 SOLAS (20) II-2/5.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 August 2023 Resolved
74SOLAS14 II-2/9.4.1.1.2 The construction of doors and frames in A-Class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame. PSCO observed fire door 6.2.05 with missing handle; fire doors 3.3.13, 3.5.13 would not latch closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 August 2023
Resolution: Crew repaired above fire doors to the satisfaction of attending PSCO-FPVE. 31AUG23
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 31 August 2023 Resolved
74SOLAS20 III/20.2 Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed retroreflective tape on the following lifeboats not reflecting light: lifeboats 1,3,5,7,9,15 starboard side tape; lifeboat 2 topside tape; lifeboat 21 bottom side tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2023
Resolved 5 September 2023
Resolution: Recieved class report with pictures of retroreflective tape on the above lifeboats. Class report attached in MISLE casework.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 28 April 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The crewmembers assigned to the portside rescue boat #2 were unfamiliar with lowering and operating the rescue boat. 74 SOLAS 20 III/19.2.1 Code 11131 Action 17c, cleared 10c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 April 2023
Resolution: Crew received training and demonstrated proper operation of rescue boat #2.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 April 2023 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. Roller shutters in galley on deck 9 did not fully close. 74 SOLAS 20 II-2/9.4.1.1.1 Code 07105 Action 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2023
Resolved 25 May 2023
Resolution: Roller shutter gap corrected. Recieved class documentation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 28 April 2023 Resolved
The company should establish procedures to ensure that new personnel are given proper familiarization with their duties. Instructions which are essential to be provided prior to sailing should be identified, documented and given. The onboard training provided was not sufficient and the personnel assigned to rescue boat #2 and life raft davit #4 were unable to carryout the duties which they are assigned. Recommend a third party audit to determine effectiveness of training being provided for the launching and operation of onboard lifesaving appliances. 74 SOLAS 20 IX/3.1 ISM Code A.6.3 Code 15105 Action 50b
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2023
Resolved 12 May 2023
Resolution: Third party audit conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 28 April 2023 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43. PSCO observed three embarkation lights on the starboard side not illuminating. 74 SOLAS 20 III/11.4 Code 11124 Action 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 28 April 2023
Resolution: PSCO walked entire embarkation deck and checked all embarkation lighting at end of exam. All embarkation lights were illuminated.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 December 2019 Resolved
Paint lockers shall be protected by a carbon dioxide, dry power, weater spraying, or similar system. 3 Paint lockers, each approx. 24 feet cube, stored in space without fire protection. 74 SOLAS 14 Chap II-2, Reg 10.6.3
Action required: 10 - Deficiency Rectified
Resolved 2 December 2019
Resolution: Vessel relocated paint into a protected space.