MAURY USCG vessel records Sign in
← All vessels

MAERSK SAIGON

MAERSK SAIGON is a 2006 freight ship. The Coast Guard has recorded 32 inspections since 2007, most recently in May 2026, along with 12 deficiencies and 3 operational controls.

Records from 2007 to 2026. Most recent: inspection, 27 May 2026.

Built
2006
Last inspected
27 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9303534 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V5630
929872
Flag
SINGAPORE
—
Maury page id
psix-929872

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2007–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it80767 - Displacement, Metric Ton
94483 - Convention (Subpart B), Gross Ton
58574 - Convention (Subpart B), Net Ton
113889 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

27 May 2026 PSC A
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8378457
2 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8318905
27 February 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8317409
6 December 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8278488
13 September 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8233680
8 July 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8170389
19 May 2025 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8135329
8 March 2025 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090458
4 March 2025 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8087729
1 March 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8086722
20 February 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8082162
3 October 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8013665
2 July 2024 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7947146
5 April 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7888547
1 April 2024 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7887876
29 March 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886900
2 January 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7844486
3 February 2023 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7631609
27 October 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7584910
9 December 2020 MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7108800
29 December 2018 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6601006
15 May 2018 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6414803
29 November 2017 Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6312020
20 September 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6270949
15 September 2017 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6265313
27 June 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6182964
2 April 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6115916
23 May 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5884335
6 February 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3143088
7 November 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3092873
5 November 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3091971
5 November 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3093340

Deficiency record · 12

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed F/O leak on #5 cylinder and #7 cylinder on #2 diesel generator. 74SOLAS(04) II-2/ 4.1.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2024
Resolution: crew cleared clogged line and cleaned cyl #5&7. See class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 April 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall e me: means shall be provided to control leaks of flammable liquids. PSCO observed excessive flammable liquids coming from open areas of sludge pump shaft. 74SOLAS(04) II-2/ 4.1.1 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 July 2024
Resolution: Rcv'd ABS report and conducted in-person def check
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 1 April 2024 Resolved
After any survey of the ship under reulations 7,8,9 or10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed unapproved modifications to include ventilation duct directed to automated valve for Deaerating Tank and portable fan directed at EGCS scrubbers SW pump. 74SOLAS(20) I/11B 40AC
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 July 2024
Resolution: Rcv'd ABS report and conducted in-person def check
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2024 Resolved
The purpose of this regulation is to limit the fire growth potential in every space. For this purpose, the following functional requirements shall be met: the use of combustible materials shall be restricted. PSCO observed wooden blocks supporting the L/O supply and discharge pipes for all cylinders on the M/E. 74SOLAS(04) II-2/ 5.1.3 40AC
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 July 2024
Resolution: Rcv'd ABS report and conducted in-person def check
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 April 2024 Resolved
The means shall be provided to control leaks of flammable liquids. PSCO observed oil soaked lagging on the #2 HFO Purifier in E/R. 74SOLAS(09) II-2/ 4.1.1 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 April 2024
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 March 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED OIL-SOAKED LAGGING IN THE PURIFIER ROOM. 74SOLAS(20)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2024
Resolution: TPO report received, condition ractified.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 March 2024 Resolved
IN A SHIP IN WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED FUEL INJECTOR LEAKING ON MAIN ENGINE CYLINDER. 74SOLAS(20)II-2/4.2.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2024
Resolution: CREW RELPACED FUEL INJECTOR SATISFACTORILY.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 January 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED EXCESSIVE ACCUMULATION OF OIL IN THE MACHINERY SPACE BILGE NEAR THE MAIN ENGINE. 74 SOLAS (09) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2024
Resolution: Received Class Report rectifying deficincies.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 January 2024 Resolved
HYDRAULIC POWER - OPERATED STEERING GEAR SHALL BE PROVIDED WITH THE FOLLOWING: ARRANGEMENTS TO MAINTAIN THE CLEANLINESS OF THE HYDRAULIC FLUID TAKING INTO CONSIDERATION THE TYPE AND DESIGN OF THE HYDRAULIC SYSTEMS, PSCCO OBSERVED EXCESSIVE ACCUMULATION OF HYDRAULIC FLUID UNDER STEERING GEAR SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2024
Resolution: Received Class Report rectifying deficincies.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 20 September 2017 Resolved
Vessel reported the phase failure relay was not operating correctly and preventing the alarms from working. 16ac
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 29 November 2017
Resolution: The Chief Mate showed documentation that a new phase failure relay had been ordered and installed by the ship's electrician. PSCO witnessed satisfactory testing of all steering gear alarms.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 2 April 2017 Resolved
0113-Every ship shall be provided with a receiver capable of receiving international NAVTEX service broadcasts. The vessel's NAVTEX receiver is currently inoperable. Vessel is required to make repairs to the NAVTEX system within 14days. 74SOLAS (14) IV 7.1.4 16c
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 April 2017
Resolved 27 June 2017
Resolution: Vessel NAVTEX receiver is fully operational.
Electrical › Electric Generation Source (emergency) › Generator
Issued 7 November 2007 Resolved
Emergency generator will start on automatic start test, but will not take a load. Vessel is required to have emergency generator fully functional prior to departure. Solas 2004, Chapter 1, reg 11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2007
Resolved 8 November 2007
Resolution: Received GL class report stating that the problem had been identified and corrected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.