MAURY USCG vessel records Sign in
← All vessels

SUPER LYDIA

SUPER LYDIA is a 2007 freight ship. The Coast Guard has recorded 10 inspections since 2007, most recently in May 2021, along with 4 deficiencies.

Records from 2007 to 2021. Most recent: inspection, 4 May 2021.

Built
2007
Last inspected
4 May 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9329423 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
930222
Flag
MARSHALL ISLANDS
—
Maury page id
psix-930222

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2007–2021)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it22698 - Convention (Subpart B), Gross Ton
12674 - Convention (Subpart B), Net Ton
37406 - Dead Weight, Ton
45382 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

4 May 2021 PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7188607
20 May 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7074154
22 March 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6109385
23 July 2015 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5193107
29 June 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4898013
11 September 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3841576
8 December 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3376401
28 August 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3311143
3 April 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3176908
6 November 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3093911

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 May 2021 Resolved
ANY REQUIRED SYSTEM SHALL BE CAPABLE OF CONTINUOUS OPERATION AT ALL TIMES. PSCO OBSERVED HOSES FOR CARGO SAMPLE EXTRACTION SMOKE DETECTION SYSTEMS WERE DISCONNECTED. SOLAS 74 (20) II-2/ 7.2.3 FSS 15.10.2.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
Resolution: CREW MEMBER RECONNECTED HOSES FOR SMOKE EXTRACTION SAMPLING SYSTEM.
Operations/Management › Pollution › Control of Garbage
Issued 22 March 2017 Resolved
Marpol Annex V/10.3.2 - 2120 - The entry of each discharge shall include date, time, position of the vessel, category, of the garbage, and the estimated amount discharged. Vessel visited Antwerp and did not notate in GRB category of garbage of estimated amount discharged. Vessel did not follow GMP on what to notate.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 22 March 2017
Resolution: Corrected on the Spot
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 June 2014 Resolved
At time of inspection, vessel MAster was hospitalized due to illness, therefore vessel was effectively non in compliance with minimum safe manning requirements. When relief master arrives onboard, vessel is to submit verification of on signing Master's Certificate of Competence and Flag State Endorsement to the COTP.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2014
Resolved 1 July 2014
Resolution: Received relief master''s license, flag state endorsement, and SSO training.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 8 December 2008 Resolved
Vsl. had a broken depth sounding device that was repaired upon entry into port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 8 December 2008
Resolved 8 December 2008

Ownership record