Records from 2012 to 2026. Most recent: inspection, 28 May 2026.
Documentation record
Registered dimensions (L × B × D)316.6 ft × 72.0 ft × 31.0 ft
Registered tonnagegross 5,993 / net 1,797
ITC dimensions (L × B × D)316.6 ft × 72.0 ft × 31.0 ft
ITC tonnagegross 5,993 / net 1,797
BuilderNORTH AMERICAN SHIPBUILDING LLC · LAROSE, LA, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 March 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7181 - Displacement, Gross Ton
2819 - Dead Weight, Gross Ton
5993 - Convention (Subpart B), Gross Ton
1797 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
28 May 2026
Administrative Inspection · Annual Inspection · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8332959
23 November 2025
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8272849
23 November 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8285657
25 June 2025
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8167590
18 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8095891
10 July 2024
ACP Additional Oversight – Risk Assessment
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7955105
16 May 2024
MTSA/ISPS Verification · Deficiency Check · ACP COI Oversight · Re-Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7888204
29 June 2023
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7724929
17 May 2022
ACP Periodic Oversight · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7454465
9 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7409792
24 February 2021
Administrative Inspection · Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7145848
27 January 2020
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6896656
16 April 2019
ACP COI Oversight · COI Inspection · Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6663047
6 July 2018
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6477855
4 December 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6317965
13 July 2017
MTSA/ISPS Verification · ACP Periodic Oversight · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6228742
6 June 2017
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168431
28 November 2016
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6048247
28 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5923056
15 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5917833
13 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876278
26 April 2016
Administrative Inspection · ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5863611
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2025
Resolved
The vessel shall comply with the construction and structural rules established by the American Bureau of Shipping. The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship and all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Vessel shall proceed directly to Chouest CI Dock to conduct repairs as necessary. Repairs completed shall be to the satisfaction of the TPO
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 December 2025
Resolved 24 November 2025
Resolution: Received TPO report verifying adequate repairs have been completed and the vessel is fit for work. Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 May 2024
Resolved
All life-saving appliances and arrangements shall comply with the applicable Code. Six hand flares complying with the requirements of section 3.2.
Marine Inspector identified one expire red flare in the port lifeboat and two expired red flares in the stbd lifeboat.
74 SOLAS (14) III/34; LSA Code/4.4.8.14
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 17 May 2024
Resolution: Vessel replaced expired flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 May 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Marine Inspector observed the crew unable to start both port and stbd lifeboats, diesel fuel in the port lifeboat, and faded stenciling of the vessels name on both port and stbd lifeboats.
74 SOLAS (14) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 17 May 2024
Resolution: Crew replaced both starters on both lifeboats. Crew installed new stenciling on both port/stbd lifeboats and removed fuel out of the port lifeboat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2024
Resolved
Fire protection systems and firefighting systems and appliances shall be maintained ready for use.
Marine Inspector identified 2 ½” hose located aft of vessel when charged had a hole at the nozzle. Hydro all hoses finding additional 2 ½” hose that was holed.
74 SOLAS (04) II/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 17 May 2024
Resolution: Crew hydro all hose finding addtional hose holed. Replace both 2 1/2" hoses with new - all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2024
Resolved
Means shall be provided to control leaks of flammable liquids.
MI observed fuel rig transfer pump leaking from shaft packing.
74 SOLAS (04) II-2/04.1.1
Action required: 10 - Deficiency Rectified
Resolved 16 May 2024
Resolution: Crew tightened packing gland. Conducted operational test with sat results.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 May 2024
Resolved
From machinery spaces other than those of category A, two escape routes shall be provided.
MI observed steering compartment watertight escape hatch was inoperable from inside the space.
74 SOLAS (04) II-2/4.2.3
Action required: 10 - Deficiency Rectified
Resolved 16 May 2024
Resolution: Crew worked the hatch including adjusting hatch enabling openining/closing - all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 May 2024
Resolved
Electrical installations shall be such that: all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions.
Marine Inspector identified two battery charges port/stbd side were plugged in not encased in a junction box.
74 SOLAS (04) II-1/40.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2024
Resolution: Shipyard installed junction boxes on both port/stbd lifeboat battery chargers.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 May 2022
Resolved
Vessel shall ensure fire protection systems and fire fighting systems shall be maintained ready for use. MI observed multiple (08+) fire stations that had the fire hose and nozzle disconnected; not ready for use. Vessel had replaced fire hoses after ABS Inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 May 2022
Resolution: Vessel crew inspected all fire stations on vessel and reconnected all hoses and nozzels.
Lifesaving › Immersion Suits › Quantity
Issued 15 June 2016
Resolved
Reduce people allowed on board to 47 due to limited lifesaving (68 immersion suits). *DO NOT CLEAR UNTIL VESSEL IS DONE OPERATING IN AK* 46 CFR 199.273 and SOLAS III/31.3
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 18 October 2017
Resolution: Vessel is no longer operating in Alaska
Documentation › Markings/Placards › Warning Signs
Issued 15 June 2016
Resolved
Modify Fire and Safety Plan to properly reflect lifesaving equipment onboard. 46 CFR 97.36-1 and SOLAS II-2/15.2.4.1
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 28 June 2016
Resolution: MSD Dutch Harbor cleared requirement.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 15 June 2016
Resolved
Issue Cargo Ship Safety Cert and Cargo Ship Safety Equipment Form E to properly reflect lifesaving onboard. 46 CFR 91.60-10 and SOLAS I/12(a)(iii)
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 28 June 2016
Resolution: MSD Dutch Harbor cleared requirement.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 26 April 2016
Resolved
Due to ongoing modifications, certificates have not been endorsed by class surveyor.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 2 May 2016
Resolution: Class Surveyor issued a condition of class for 30 days to have owner resubmit plans reflecting minor changes.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 26 April 2016
Resolved
Vessel made modifications to cargo/fuel tanks. Provide transfer procedures reflecting new installation.
Action required: 703 - Prior to bunkering operations
Due 27 April 2016
Resolved 27 April 2016
Resolution: Class surveyor observed new pipe diagram and transfer procedures onboard.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 26 April 2016
Resolved
Vessel to add immersion suits and will updated fire control plan to reflect change
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 2 May 2016
Resolution: owner purchased 25 CG/SOLAS approved immersion suits and updated fire control plan
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 April 2016
Resolved
Vessel's E/R starboard fwd bilge alarm was inoperable
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 27 April 2016
Resolution: ABS surveyor witness bilge alarm operating
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 26 April 2016
Resolved
Vessel's RAI in the steering compartment was 15 degrees off of the indicator on the rudder post.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 27 April 2016
Resolution: ABS surveyor witness steering test from multiple positions and degrees with positive results
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 April 2016
Resolved
Door on electrical panel (P-402) was not secured.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 27 April 2016
Resolution: ABS surveyor witnessed the door fastened as designed
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2016
Resolved
02 Rox block penetrations were not secured.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 27 April 2016
Resolution: ABS surveyor witnessed the wiring completed and penetration secured.