← All vessels
SHAKE A LEG
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Great Lakes District (CGD-GL) · Other hulls named SHAKE A LEG
SHAKE A LEG is a 2008 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2008, most recently in April 2026, along with 31 deficiencies, 1 operational control and 2 casualty investigations between 2010 and 2011.
Records from 2008 to 2026. Most recent: inspection, 8 April 2026.
- Built
- 2008
- Last inspected
- 8 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 31 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2010–2011
Identity
1212945
WDE5311
930778
Flag
UNITED STATES
367364840
Maury page id
psix-930778
Inspections, by type
…with no type recorded1
Years with a record
17 calendar years (2008–2026)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 6.7 ft
Registered tonnagegross 40 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderANDERSEN BOAT WORKS INC · SAUGATUCK, MI, UNITED STATES · built 2008
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Gross Ton
32 - Simplified, Net Ton
32 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE5311MMSI 367364840 · active · compulsorily equipped · granted 3 May 2018, expires 25 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 35
8 April 2026
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8344526
16 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8279159
24 April 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8119912
9 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8108709
11 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7893470
14 March 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7648161
23 August 2022
Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7541882
11 April 2022
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7428460
27 October 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7340844
12 May 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7195513
1 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6992865
14 May 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6955716
2 May 2019
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6675895
21 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6419820
26 March 2018
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6429249
8 March 2018
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6368066
2 March 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6098254
5 October 2016
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6025687
8 March 2016
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5829362
23 July 2015
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5197647
19 March 2014
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4821505
6 March 2014
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4819260
26 September 2011
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4154805
15 September 2011
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4146219
12 September 2011
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4144040
21 September 2010
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3855020
20 September 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3865224
15 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3853291
3 July 2009
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3526556
4 May 2009
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3467660
23 April 2009
Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3459062
29 December 2008
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3385830
3 October 2008
Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3338078
7 August 2008
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3291950
13 May 2008
Simplified Stability Test · Administrative Inspection · Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3205684
Deficiency record · 31
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2025
Resolved
The owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections to include all accesible parts of exterior and interior of the hull, the water tight bulkheads, and weather decks. In the #3 void on the aft WTB, there are 4 holes approx. 1/8" diameter drilled through. Make permanent acceptable repairs with local OCMI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 April 2024
Resolved
The Fire pump gauge is not operating as designed. Pump appears to be discharging and the gauge is reading less than 5 psi. Verify pump and gauge operation.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 11 April 2024
Resolved
Bilge high level alarm housings are broken allowing alarm to float free in the engine space and lazerette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 March 2023
Resolved
Emergency fuel shut-off cable bracket is cracked. Valve does operate, brackets needs repair.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2019
Resolved
Stations in the maritime serivce must be licensed by the FCC. Vessel's FCC Station license is expired. Prove/post current valid FCC Station license to satisfaction of attending Marine Inspector.
47CFR80.13
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 May 2019
Resolved
Ring life buoys shall be of first class workmanship and free from any defects materially affecting their apperance or serviceability. Vessel has righ buoy with grab/light attachment line deteriorating. Repair/replace deteriorating line to the satisfaction of attending Marine Inspector.
Fire Fighting › Fire Pumps › Power Source
Issued 8 March 2018
Resolved
Provide Secondary capabilities to energizes fire pumps
Engineering › Bilge Water Management System › Pump
Issued 19 March 2014
Resolved
Prove operation of vessel's bilge pump
Engineering › Reduction Gearing/Clutches › Gear
Issued 19 March 2014
Resolved
Repair or replace wiring on sending unit on stbd MDE reduction gear (wiring chaffed through)
Fire Fighting › Fire Pumps › Arrangement
Issued 19 March 2014
Resolved
Prove operation of vessel's fire pump.
Engineering › Fuel Oil Service System › Hose
Issued 19 March 2014
Resolved
Replace fuel return hose on port MDE (Chaffed through)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 March 2014
Resolved
Install Chaffe gear on hoses on both MDEs.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 September 2011
Resolved
Corrected error with issue & expiration dates of COI
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 September 2011
Resolved
Emergency Instructions were not posted as required. Also emergency instructions kept onboard were not specific to vessel & vessel crew manning. Company must draft emergency instructions that are specific to vessel & crew, & post IAW 46CFR185.510
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 September 2011
Resolved
Pull cable for the remote fuel shutoff valve was missing the pin on the end that locks the valve open during normal operation. Currently the pull cable is fed through the locking holes and is beginning to kink. Eventually the kinked cable may bind up the shut off mechanism. Company must repair/replace locking pin on the end of the pull cable. 46CFR182.455(b)(4)
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 September 2011
Resolved
Label deck near handle for remote fuel shutoff valve. Currently the bulkhead is labeled, but there is a shelf that is obstructing view of the label. 46CFR185.608
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 September 2011
Resolved
There is a piece of flexible hose installled in the fuel tank fill piping that separates two separate pieces of steel piping. Currently the two pieces of steel piping are not properly bonded to one another with a copper conductor to prevent the build up of static electricity. Company must properly bond both sections of steel piping IAW 46CFR182.455(g) prior to fueling.
Engineering › Fuel Oil Service System › Piping
Issued 12 September 2011
Resolved
The remote fuel shut off valve and the first pipe union in the fuel line after the remote shut off are leaking diesel fuel. Company must repair fuel leaks. 46 CFR 176.804(e)
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 September 2011
Resolved
Ring Life Buoy did not have required retro-reflective tape. Company must attach retro-reflective tape. 46 CFR 185.604(h)
Electrical › Electric Supply System (service) › Battery Charger
Issued 12 September 2011
Resolved
Alternators on both Main Diesel engines were dirty and windings were covered in oil. Company must have both engine alternators opened up and cleaned. 46 CFR 176.806
Electrical › Electrical Distribution System (service) › Fuse
Issued 12 September 2011
Resolved
Fuses used for the 24 volt DC power distribution are not UL listed for marine use. Company must replace installed fuses with fuses that have been UL listed for marine use. 46 CFR 183.380(k)(1)
Stability › Watertight Integrity › General
Issued 12 September 2011
Resolved
Two fittings that pass through the FWD water tight bulkhead in the aft steering compartment are not properly sealed. Company must properly seal the fittings with "Fire Stop" sealant or another acceptable means. 46 CFR 179.320(c)
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 12 September 2011
Resolved
Vessel's rudder angle indicator is operating intermittingly. Company must repair or replace rudder angle indicator and prove proper operation. 46 CFR 182.610(f)(2)
Fire Fighting › Ventilation Systems › Ducts
Issued 15 September 2010
Resolved
Prove proper operation of both engineroom vent dampers.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear/Clutch Starter (electric)
Issued 4 May 2009
Resolved
Prove proper operation of port MDE IAW 46 CFR 182.200 prior to carrying passengers to the satisfaction of Coast Guard Marine Inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 May 2008
Resolved
Install proper machine guards on both MDE's.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 May 2008
Resolved
Install proper lagging on stbd MDE IAW 46 CFR 182.430(g).
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 13 May 2008
Resolved
Properly secure pipes & wires /wire trays in overhead of engineroom.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 13 May 2008
Resolved
Properly complete MSD system IAW approved plans & 46 CFR 184.704.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 May 2008
Resolved
Properly install marine radar system IAW 46 CFR 184.404. Vsl is limited to Rivers route until completed to USCG Marine Inspector's satisfaction.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 13 May 2008
Resolved
Obtain approved electrical plans from MSC and notify local OCMI to verify installation of electrical matches approved plans.
Casualty record · 2
20 September 2010Routine · role: Involved in a Marine Casualty · activity 3865224
8 June 2011Routine · role: Involved in a Marine Casualty · activity 4089222
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.