MAURY USCG vessel records Sign in
← All vessels

CARIBBEAN EXPRESS I

CARIBBEAN EXPRESS I is a 2000 freight ship. The Coast Guard has recorded 92 inspections since 2000, most recently in July 2026, along with 59 deficiencies and 13 operational controls.

Records from 2000 to 2026. Most recent: inspection, 15 July 2026.

Built
2000
Last inspected
15 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9233727 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
338264000 (licence lapsed)
Maury page id
psix-9308

Inspections, by type

…with no type recorded26
Years with a record 26 calendar years (2000–2026)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it499 - Convention (Subpart B), Gross Ton
499 - Simplified, Gross Ton
156 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCZ9369MMSI 338264000 · expired · compulsorily equipped · granted 14 July 2000, cancelled 18 September 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DUPLICATE OF VIKING EXPRESS (IMO 11941099) Freight Ship · MISLE 660542 · 12 June 2003 · activity 1825380

Inspection history · 92

15 July 2026 PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8438658
17 March 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8327376
6 January 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8290798
14 August 2025 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8209999
11 August 2025 PSC B · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8207260
6 August 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8203584
5 February 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8074486
31 July 2024 PSC B · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7966669
5 June 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7929224
5 April 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890481
25 January 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7855601
24 July 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7750499
23 January 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7625071
19 January 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7623933
14 January 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7621522
6 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7525956
8 July 2022 PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7499749
5 January 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7375535
23 June 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7232990
17 March 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7158012
15 December 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7107984
29 May 2020 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6963610
5 November 2019 ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6849337
7 May 2019 ISPS III Exam · CCSSC Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6678495
2 April 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6654267
21 January 2019 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6612857
13 November 2018 Deficiency Check · Ballast Water Examination · Administrative Inspection · CCSSC Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6579402
16 May 2018 MTSA Verification · Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6414739
16 November 2017 MTSA Verification · CCSSC Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6308267
19 May 2017 CCSSC Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6149964
23 February 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6093231
14 November 2016 CCSSC Examination · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6040387
17 October 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6024070
6 May 2016 ISPS II Exam · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5870260
19 February 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5818553
29 October 2015 Ballast Water Examination · CCSSC Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5753366
22 August 2014 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4962562
12 May 2014 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4856286
14 May 2012 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4310840
27 July 2011 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4097086
27 July 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4097455
17 December 2010 PII Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3912336
25 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3685597
16 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3680309
9 December 2009 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3647560
13 January 2009 PII Safety Exam · CCSSC Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3393469
8 December 2008 ISPS II Exam · Ballast Water Examination · PI Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3376078
28 March 2008 PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3172775
5 March 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3158945
9 February 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3144569
2 July 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2980567
16 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2963200
9 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2870363
17 August 2006 ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2756420
11 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2565058
10 January 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563986
9 January 2006 NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2565863
26 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2522789
18 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2516998
13 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2513564
11 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2511985
26 September 2005 MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501758
26 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501773
21 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501067
21 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2516841
12 September 2005 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2490698
22 April 2005 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2340648
1 November 2004 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2232261
26 June 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2113369
28 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2055782
26 April 2004 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2052669
25 March 2004 Examination of Repairs · Administrative Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2030968
17 February 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2007511
8 October 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1923660
1 October 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1918419
28 August 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1890024
12 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1825380
2 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1784882
20 March 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1759946
15 October 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1690500
1 October 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1682502
27 August 2002 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 1679364
28 March 2002 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1598566
2 March 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1490635
29 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295925
31 October 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295223
16 October 2000 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 823990
27 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 638293
8 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 213524
8 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 222253
28 June 2000 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 823413
28 June 2000 COI Inspection · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1427827

Deficiency record · 59

01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 15 July 2026 Resolved
...Each complete page...shall be signed by the Master of the ship. Complete pages in the ORB have not been signed by the Master since 04MAY2026. MARPOL I/17.4 15c
Action required: 15 - Rectify deficiencies by next port
Resolved 15 July 2026
Resolution: Master signed all ORB pages since 04MAY2026.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 15 July 2026 Resolved
The Oil Record Book shall be completed on each occasion...whenever any of the following machinery space operations take place in the ship: collection and disposal of oil residues(sludge). Since February, three distinct discrepancies in the disposal of sludge are recorded in the ORB. Between 22FEB2026 and 05MAR2026, 0.32m^3(84.5 gallons) of sludge is unaccounted. Between 18MAR2026 and 21MAR2026, 0.04m^3(10.5 gallons) of sludge is unaccounted. Between 22MAY2026 and 17JUN2026, 0.037m^3(9.5 gallons)of sludge is unaccounted. In total, 0.397m^3(105 gallons) of sludge is unaccounted. Vessel must provide 30 days worth of ORB entries on the due date of this deficiency. MARPOL I/17.2.3 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2026
Resolved 15 August 2026
Resolution: Chief Engineer accurately recorded sludge soundings and disposal since 15 JUL 26.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2026 Resolved
...Each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. Vessel has not hydrostatically tested their fuel bunker lines since October 2022. A test must be completed prior to bunkering in U.S. waters. 33 CFR 154.170(c)(4) 40bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 July 2026
Resolution: Deficiency cleared and re-issued as Code 17 in MISLE Activity #8441543
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 15 July 2026 Resolved
Life-saving appliances required by this chapter should comply with the technical specifications of the LSA Code. The normal equipment in every rescue boat shall consist of: a searchlight with a horizontal and vertical sector of at least 6deg and a measured luminous intensity of 2500 cd which can work continuously for not less than 3 hours. Rescue boat does not have a searchlight. CCSSC 4.3.1 LSA 5.1.2.2.11 40bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 July 2026
Resolution: Deficiency cleared and re-issued as Code 17 in MISLE Activity #8441543
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 July 2026 Resolved
The rings, lines, and letters shall be..permanently marked on the sides of the ship to the satisfaction of the administration. Vessel's "F" and "S" marking for the Freshwater and Summer Line are not permanently marked on either side of the vessel. ILLC (PROT 88) Reg 8 40bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 July 2026
Resolution: Deficiency cleared and re-issued as Code 17 in MISLE Activity #8441543
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 15 July 2026 Resolved
Vessels with ballast water tanks operating in U.S. waters must...remove fouling organisms from the vessel's hull...on a regular basis and dispose of any removed substances. The vessel's hull has significant marine growth on the stern, port quarter, and starboard quarter. 33 CFR 151.2050(F) 40bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 July 2026
Resolution: Deficiency cleared and re-issued as Code 17 in MISLE Activity #8441543
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 January 2026 Resolved
Subject to the provisions of 3.16.1.2 and 3.16.1.3, The fire safety requirements of bulkheads, decks, doors and stairways should, as far as practicable and reasonable in the opinions of the administration, comply with the applicable requirements of the 1974 SOLAS convention for such bulkheads, doors and stairways. In addition to complying with the specific provisions for fire integrity of bulkheads and decks of cargo ships, the minimum fire integrity of bulkheads and decks shall be as prescribed in tabled 9.5 and 9.6. PSCO observed fire boundaries for bridge, galley, accommodation spaces, and engine room do not comply with the provisions of table 9.5 of 1974 SOLAS II-2. CCSSC(97) 3.16.1.1 74 SOLAS (20) II-2/9.2.3.3.1 17bc reduced to 50bc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2026
Resolved 6 January 2026
Resolution: Deficiency re-issued as 50bc. Refer to def #4.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 January 2026 Resolved
Ventilation systems of each of the following groups of spaces should be entirely separated from each other: 1. Machinery Spaces, 2. Galleys, 3. Cargo spaces and accommodation spaces and control stations. The arrangement of each ventilation system should be such that fire in one space should not readily spread to other spaces. PSCO observed the ship only has one ventilation system to supply all compartments on board. CCSSC (97) 3.16.6.1 17bc reduced to 50bc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 6 January 2026
Resolved 6 January 2026
Resolution: Deficiency re-issued as 50bc. Refer to Def #5
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance Dangerous Goods
Issued 6 January 2026 Resolved
The Administration shall provide the ship with an appropriate document as evidence of compliance of construction and equipment with the requirements of this regulation. Certification for dangerous goods...is not required for those cargoes specified as class 6.2 and 7 and dangerous goods in limited quantities and expected quantities. PSCO observed the vessel's document of Compliance for the Carriage of Dangerous Goods does not accurately reflect the proper loading locations for the dangerous goods. 74SOLAS(20) II-2/19.4 50bc
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2026
Resolved 19 February 2026
Resolution: received updated DOC for Dangerous Goods, attached in Documents
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 January 2026 Resolved
Subject to the provisions of 3.16.1.2 and 3.16.1.3, The fire safety requirements of bulkheads, decks, doors and stairways should, as far as practicable and reasonable in the opinions of the administration, comply with the applicable requirements of the 1974 SOLAS convention for such bulkheads, doors and stairways. In addition to complying with the specific provisions for fire integrity of bulkheads and decks of cargo ships, the minimum fire integrity of bulkheads and decks shall be as prescribed in tabled 9.5 and 9.6. PSCO observed fire boundaries for bridge, galley, accommodation spaces, and engine room do not comply with the provisions of table 9.5 of 1974 SOLAS II-2. CCSSC(97) 3.16.1.1 74 SOLAS (20) II-2/9.2.3.3.1 50bc
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 21 July 2026
Resolution: Received final survey documentation attesting to final modifications installed and inspected satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 January 2026 Resolved
Ventilation systems of each of the following groups of spaces should be entirely separated from each other: 1. Machinery Spaces, 2. Galleys, 3. Cargo spaces and accommodation spaces and control stations. The arrangement of each ventilation system should be such that fire in one space should not readily spread to other spaces. PSCO observed the ship only has one ventilation system to supply all compartments on board. CCSSC (97) 3.16.6.1 50bc
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2026
Resolved 21 July 2026
Resolution: Received final survey documentation attesting to final modifications installed and inspected satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 August 2025 Resolved
Bulkheads forming boundaries between cargo spaces and machinery spaces of category A shall be insulated to "A-60" standard. PSCOs ovserved lack of required A-60 insulation in machinery space below stowage of dangerous goods. 74SOLAS(01) II-2/54.28
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 14 August 2025
Resolution: The PSCO confirmed that deck markings designating areas aft of transverse frame # 37 were not allowed for storage of dangerous goods (HAZMAT) due to lack of required A-60 rated boundary. 01 deficiency removed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 11 August 2025 Resolved
Life-saving appliances required by this chapter shall comply with the technical specifications of the LSA code and National Regulations as appropriate. Structural members and all blocks, falls, padeyes, links, fastenings and all other fitting used in connection with launching equipment shall be designated with a factor of safety on the basis of the maximum working load assigned and the ultimate strengths of the materials used for construction. A minimum factor of safety of 4.5 shall be applied to all structural members and a minimum factor of safety of 6 shall be applied to falls, suspensions, chains, links, and blocks. PSCO's observed the the rescue boat weighing 700 lbs with the launching apparaus being aed for a S.W.L. of 1.1 tons, this not meeting safety factors required by the CCS and LSA code. CCS Code 4.3.1 LSA Code 6.1.1.6
Action required: 10 - Deficiency Rectified
Resolved 14 August 2025
Resolution: Confirmed Flag survey documentation identifying and approving satisfactory type approval and testing of the the rescue boat davit and it's associated equipment.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 31 July 2024 Resolved
Every oil tanker of 150 gross tonnage and above and every ship of 400 gross tonnage and above other than an oil tanker shall be provided with an oil record bok part I. The oil record book, whether as a part of the ship's official loogbook or otherwise shall be in form specified in appendix III of this Annex. PSCO's observed weekly soundings were not recorded in the oil record book. MARPOL ANNEX I Reg 17.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 August 2024
Resolved 1 August 2024
Resolution: Deficiency rectified on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 January 2023 Resolved
If the Coast Guard determine that the VRP meet an requirement all requirement of this subpart, this Coast Guard will notify the vessel owner or operator with an approval letter. The VRP will be valid for a period of 5 years from the date of approval...PSCO's discovered the vessels VRP was expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 January 2023
Resolution: Agent submitted NTVRP approval letter with approved VRP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2022 Resolved
The owner or Master of every ship to which this code applies shall ensure that: the condition of the ship and its equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board, or the environment. Main port side engine experienced loose valve gear in cylinder number 1 while underway. CCSSC 1.11.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2022
Resolution: Flag attestation received.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 November 2018 Resolved
0635 - Launching Appliances for Rescue boats - Falls shall be of rotation-resistant steel wire rope. PSCO noticed falls on rescue boat davit tangled to create a "birds nest" and require replacement. - CCSSC CH.4.3.1 , LAS Code 6.1.2.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 November 2018
Resolved 21 November 2018
Resolution: Vessel renewed wire rope on rescue boat launching davit. Flag state attestation accepted.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 13 November 2018 Resolved
0120 - Load Line - The international Load Line Certificate (1966) shall not be delivered to the ship until the offer or suveryor acting under the provisions of Article 13 of the present convention has certified that the marks are correctly and permanently indicated on the ships sides. Starboard side load line is marked incorrectly and is not in line witht he plimsoll mark. - ICLL 66/68 Annex 1 reg 9
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 30 November 2018
Resolution: Plimsol mark was removed and a new one was welded on and painted in accordance with their International Load Line Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 November 2018 Resolved
9900- other (non hazardous) - The strength and construction of hull, machinery casing...shall be sufficient to withstand all foreseeable conditions of the intedned service. Port Side shaft seal leaking 1 gallon every 4 minutes. - CCSSC Ch. 2.4.1 Ship to rectify deficiency during dry dock scheduled for January 2019.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2018
Resolved 2 April 2019
Resolution: Received report from flag state surveyor attesting to the mechanical seal being installed on the port shaft during dry dock securing the excessive leak (see documents)
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 16 November 2017 Resolved
The position of the rudder, if power operated, shall be indicated at the navigation bridge. Conning position on the brige has 02 rudder angle indicators that show different readings of up to 6 degrees off from each other.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 November 2017
Resolved 17 November 2017
Resolution: Flag attestation of satifactory repairs to the rudder angle indicators.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 16 November 2017 Resolved
In ships of 50M in length and over at least two of the lifebuoys provided with self-igniting lights IAW 4.12.2 shall also be provided with self activating smoke signals. Port and Starboard lifebuoys fitted with smoke signals had the self-igniting lights removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 17 November 2017
Resolution: Cleared on the spot.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 17 October 2016 Resolved
03 - 0740 - CCSSC CHAP 3.3.10.1 AN EMERGENCY FIRE PUMP SHALL BE POSITIONED OUTSIDE THE ENGINE ROOM AND PERMANENTLY CONNECTED TO THE FIREMAINS. THE USE OF PORTABLE FIRE PUMPS SHALL BE AVOIDED. SHIP DOES NOT HAVE FIXED EMERGENCY FIRE PUMP.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 15 February 2017
Resolution: Flag survey report submitted attesting to installation of fixed emergency fire pump.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 May 2012 Resolved
VALVES ON OWS DO NOT STOP THE FLOW OF OILY WATER OVERBOARD WHEN CONTENT EXCEEDS 15PPM
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2012
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 27 July 2011 Resolved
All gearing, shaft, and coupling used for machinery essential for propulsion and safety of the ship should be so designed and constructed that they will withstand the maximum working stresses to which they may be subject. Vessel lost propulsion while entering port (Dania Beach). Repairs conducted to the satisfaction of attending technician. Vessel required to have flag surveyor attest to effect
Action required: 15 - Rectify deficiencies by next port
Resolved 29 July 2011
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 December 2010 Resolved
The position of the rudder, if power operated, should be indicated at the navigation bridge. Rudder Angle indicator is off 8 Degrees. CCSSC 2.22.8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2010
Resolution: Rudder Angle indicator is now in line and reading accurately with the bridge.
Engineering › Steering Gear System › Chain
Issued 17 December 2010 Resolved
The auxillary means of steering should be of adequate strength and sufficient to steer ship at navigable speed and capable of being brought speedily into action. Vessel emergency steering could not be operated rudder could only be shifted to 10 degrees after a period of 5 minutes. CCSSC 2.33.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2010
Resolution: Vessel''s crew was able to operate the Emergency steering with no problem and rudder was able to shift to a minimum of 15 degrees port and starboard.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 17 December 2010 Resolved
The Caribbean Cargo Ship Safety Certificate shall be supplemented by a record of Equipment and ship information which should be permanently attached thereto. Vessel is missing the Record of Equipment. CCSSC 1.12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 17 December 2010 Resolved
Vessel is not manned in accordance with the Safe Manning Document. Vessel is missing 01 Able Seaman. STCW 95 I/4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2010
Resolution: Vessel added an Able Seaman and is now in accordance with the Safe Manning Document.
Fire Fighting › Fire Bucket › Quantity
Issued 17 December 2010 Resolved
Five Buckets should be of material which is not readily flammable, they should be painted red, clearly marked with the word fire and provided with lanyards of sufficient length. Vessel has no Fore buckets on board. CCSSC 3.7.1
Action required: 705 - Other - as specified
Due 24 December 2010
Resolved 29 April 2011
Operations/Management › Drills/Instruction › Fire
Issued 17 December 2010 Resolved
Training Drills shalll be as far as practicable be conducted as if there were an actual emergency. Fire Drill was conducted twice. Both were not satisfctory due to crew training( Drill conducted in the galley and the paint locker). Captain and crew knowledge of shipboard training are unsatisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2010
Resolution: Fire Drill conducted in the paint locker was done satisfactorily.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 28 March 2008 Resolved
Vessel needs to submitt NTVRP for approval
Action required: 705 - Other - as specified
Due 8 December 2008
Resolved 8 December 2008
Resolution: NTVRP submitted and Pending.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 February 2008 Resolved
Fire Control Plan missing approval stamp.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 5 March 2008
Resolution: Class provided certificate approving all three copies of FCP. Certifcate now accompianes FCP.
Personnel › Manning/Qualifications › Medical Fitness
Issued 9 February 2008 Resolved
Chief Engineer and 2 AB's have expired medical certificates.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2008
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 9 February 2008 Resolved
2nd Engineer does not possess a valid national license or flag endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2008
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 9 February 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2008
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 10 January 2006 Resolved
Vessel failed to comply with a COTP order. Vessel entered Port Everglades while the Port was was closed for post hurricane assesement. Vessel violated COTP order to remain in the designated anchorage.
Action required: 705 - Other - as specified
Resolved 10 January 2006
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 9 January 2006 Resolved
Master and Chief mate are missing flag state endorsement
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 August 2006
Resolution: Master and Chief mate had appropriate licences and endorsements.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 9 January 2006 Resolved
SOPEP needs to be updated.
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 12 January 2006
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 26 October 2005 Resolved
Vessel entered PEV after being told the port was closed due to Hurricane Wilma and also did not submit a proper ANOA to the NVMC.
Action required: 15 - Rectify deficiencies by next port
Due 26 October 2005
Resolved 27 October 2005
Resolution: Vessel was released by the COTP and allowed to continue on with their voyage.
Documentation › Logs/Records › Oil Record Book
Issued 26 September 2005 Resolved
Vessel did not correctly fill out the Oil Record book part I properly. The vessel Oil Record book was missing amount ofuel taken oboard, type of fuel, and destination.
Action required: 705 - Other - as specified
Due 3 October 2005
Resolved 31 October 2005
Resolution: Recieved report of oil record book training. Veirifed correct oil record book entries.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 22 April 2005 Resolved
Rescue boat does not have outboard engine.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2005
Lifesaving › Rescue Boat › Hull (rigid)
Issued 22 April 2005 Resolved
Rescue boat suffered severe impact when wire rope parted during lowering operations. Provide replacement rescue boat or survey report from the administration attesting to the condition of the rescue boat hull.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2005
Lifesaving › Launching Appliances › Winch
Issued 22 April 2005 Resolved
Rescue Boat winch cable is boken.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2005
Electrical › Electric Supply System (service) › Battery Conductor
Issued 22 April 2005 Resolved
Rescue boat power supply to lowering winch is inadequate.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2005
Navigation › Piloting/Steering
Issued 25 March 2004 Resolved
Provide non-destructive testing of weld material utilized for connecting bar for the rudder system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2004
Resolution: Non-destructive testing report provided.
Fire Fighting › Means of Escape
Issued 1 October 2003 Resolved
Spring on hatch to the emergency escape from the bow thruster space is wasted and siezed. Egress from bow thruster space is not acceptable. Replace spring to emergency escape hatch. Should be verified on 01OCT03. LEGACY COMPONENT DESC: Deck Hatch
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 6 February 2004
Fire Fighting › Remote Fuel Shutoff
Issued 1 October 2003 Resolved
Remote fuel shut-off is not installed IAW CCSSC. Install IAW CCSSC 3.19.2.3. Provide proposal to MSO. Proposal received, vessel allowed to depart. LEGACY COMPONENT DESC: Bow Thruster
Due 1 November 2003
Resolved 6 February 2004
Pollution Prevention/Response › Prevention Equipment
Issued 1 October 2003 Resolved
Prove proper operation of OWS. IOPP Certificate requires OWS w/ automatic stop and alarm. Amend certificate or install OWS w/ automatic stop and alarm. Demonstrate ability to detect oily water mixtures greater than 15 ppm. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 703 - Prior to bunkering operations
Due 1 November 2003
Resolved 6 February 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 October 2003 Resolved
Bow thruster space does not have fixed-fire protection or fire detection. Space is a periodically unattended machinery space. Have flag State representative address deficiency and provide report to MSO Miami.
Due 1 November 2003
Resolved 7 November 2003
Documentation › Certificates/Documents
Issued 1 October 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Due 15 October 2002
Resolved 14 October 2002
Personnel › Manning/Qualifications
Issued 1 October 2002 Resolved
Provide an additional licensed engineer IAW requirements of STCW '95. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2002
Resolution: Vessel provided another licensed engineer in lieu of the oiler.
Construction/Loadline › Markings
Issued 1 October 2002 Resolved
Properly and permanently affix Plimsoll mark on Port and STBD sides of vessel. Currently loadline is only painted on. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2003
Resolved 29 August 2003
Fire Fighting › Miscellaneous Items
Issued 1 October 2002 Resolved
Provide new fire plan to include color coating.
Condition: Unknown
Due 15 October 2002
Resolved 15 October 2002
Lifesaving
Issued 31 October 2001 Resolved
Provide a Flag report attesting to the operation of the davit for the rescue boat.
Condition: Unknown
Due 31 October 2001
Resolved 2 November 2001
Documentation
Issued 31 October 2001 Resolved
Provide all seamen books for all AB onboard.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Construction/Loadline
Issued 28 June 2000 Resolved
PROVIDE COMMON RAIL BILGE VALVES THAT ARE POWER DRIVEN FROM THE SPACE WHERETHE BILGE PUMP IS LOCATED (ENGINE ROOM) IAW 46 CFR 56.50-50(c)(3)(iii).
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Documentation
Issued 28 June 2000 Resolved
PROVIDE A VALID SOPEP FOR THE VESSEL IAW 33 CFR 151.26.
Condition: Unknown
Due 28 July 2000
Resolved 27 July 2000
Engineering
Issued 28 June 2000 Resolved
PROVIDE SHAFT SPEED INDICATORS IAW 46 CFR 113.37-5 FOR BOTH PORT AND STARBOARD SHAFTS.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Accommodation/Occupational Safety
Issued 28 June 2000 Resolved
PROVIDE A QMED QUALIFIED CREWMAN UNTIL SUCH TIME AS ITEM NUMBER ONE (1) IS COMPLETED.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000

Ownership record