Records from 2016 to 2026. Most recent: inspection, 20 March 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult. Child PFD container not properly marked nor separated from adult PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 27 April 2026
Resolution: Labeling corrected, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 20 March 2026
Resolved
Each vessel must be equipped with at least two operable portable batter lights. One of these lights must be located at the operation station and the other at the access to the propulsion machinery space. Only one portable light on board the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 27 April 2026
Resolution: Additional flashlight placed onboard, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2026
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Eyewash in kit expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2026
Resolved 27 April 2026
Resolution: Expired eyewash renewed, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 February 2025
Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required. Vessel is missing a fire extinguisher IAW COI. Install additional extinguisher.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 March 2025
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 February 2025
Resolved
Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Installed fire extinguisher was serviced in 2023. Install new fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 February 2025
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel had 04 flares. Add additional flares.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 February 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Identification of the items are letters and numbers must be at least (2 inches) high.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 March 2025
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 4 February 2025
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25. Portable fuel tank is delaminating and cracking. Install new approved portable tank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2025
Resolved 18 March 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 March 2023
Resolved
Vessels inspected under Subchapter-T are required to undergo an annual inspection within 3 months before or after each anniversary date. Vsl was not made available for annual inspection within the annual window. Vsl must submit a new CG 3752 Application for Inspection of U.S. Vessel and be made available for inspection. 46 CFR 176.500
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 March 2023
Resolution: COI inspection conducted this date. COI issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2023
Resolved
Portable fire extinguishers must be maintained iaw NFPA 10. Both portable fire extinguishers are serviceable but require annual and monthly inspection cert. Vsl must provide evidence that annual inspection was completed iaw NFPA 10. 46 CFR 175.600
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Inspection tags were provided and proof of monthly inspections made.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2023
Resolved
Brackets for portable fire extinguishers must be maintained iaw NFPA 10. Both fire extinguisher brackets were wasted and unserviceable. Vsl must provide serviceable storage brackets for both fire extinguishers.46 CFR 175.600
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: New portable fire extinguisher bracket provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 March 2023
Resolved
Vsl which dont require power bilge pumps must provide three 2.5 gal fire buckets. Vsl only had two fire buckets onboard. Vsl must provide three fire buckets.46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 8 March 2023
Resolution: Third fire bucket provided prior to CGMI departure.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 March 2023
Resolved
Audible sound signals must meet the requirements in 33 CFR 164. Installed horn is not loud enough to meet the decibel requirements. Vsl must provide horn or sound producing device which meets the requirements of this part.33 CFR 164
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: New horn provided, tested all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023
Resolved
Instructions for dawning PFD must be provided for passengers. Instructions provided are not for the make/model PFD which are carried onboard. Vsl must provide instructions for the make/model PFD currently onboard.46 CFR 185.516
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Correct PFD dawning instructions provided for make and model PFD provided.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 8 March 2023
Resolved
SPV are required to maintain an FCC radio station license which assigns the vessel's call sign. Vsl FCC radio station license is expired. Vsl must renew the FCC radio station license and amend all other FCC documents with the new call sign.47 CFR 80
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: FCC radio documents provided. VHF test conducted SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 March 2023
Resolved
Storage container for distress signals must be labeled "DISTRESS SIGNALS". Storage container was labeled but was bleached out by the sun. Vsl must relabel storage container for distress signals.46 CFR 185.614
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Distress signal storage container properly labeled.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 March 2023
Resolved
A living document to record monthly fire extinguisher maintenance and crew training must be available. Vsl is not logging monthly fire extinguisher maintenance or crew training. Vsl must provide a logbook to show the attending CGMI crew training and portable fire extinguisher maintenance is being conducted.46 CFR 185.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
Resolution: Master created smooth log to record crew training and portable fire extinguisher monthly maintenance/inspections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 November 2021
Resolved
Owner or managing operator make available for inspection necessary to determine that they are in suitable condition. The hydraulic actuator seals are leaking by and hoses are damaged. Replaced in kind.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: Company provided repair report stating repair plan and materials used. MI's inspected and witnessed operating system. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 November 2021
Resolved
Bilge pumps, hoses, of good quality and substantial construction. The bilge pump hose is worn and wasted.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: Bilge pump hose and OVBD fitting was replaced with in kind materials. Operational check was SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 November 2021
Resolved
Each ring buoy on vessel must be IAW 160.050 sub Q. The vessel ring buoy is wasted. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: Ring buoy and throw bag was replaced in-kind. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 November 2021
Resolved
Each portable fire ext. on a vessel must be of an approved type. The aft port fire ext. is damaged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: Port fire ext. was replaced in-kind. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 November 2021
Resolved
Appropriately mark and separate life jackets. The forward compartment needs to be properly marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: All compartment covers have legible markings. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 30 November 2021
Resolved
Inspection standards due consideration must be given to hazards involved, the port and starboard access steps need non-skid replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: The non-skid on all ladder steps have been replaced with new non-skid strips. All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 November 2021
Resolved
Master or managing operator shall instruct each crewmember. conduct drills in the presence of the attending [name withheld] drills.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 12 January 2022
Resolution: M/I's conducted fire and abandon ship drills. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 November 2020
Resolved
Provide employee list for DAPI audit.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2020
Resolved 16 November 2020
Resolution: O/O provided updated employee list.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 10 November 2020
Resolved
Loose handrails throughout
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 November 2020
Resolution: All rails were properly tightened.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 November 2020
Resolved
Loose cleats throughout
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 November 2020
Resolution: Cleats were properly tightened
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 10 November 2020
Resolved
Port scupper drain broken off.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2020
Resolved 16 November 2020
Resolution: The scupper was renewed and properly installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 November 2020
Resolved
Port fire extinguisher missing service tag
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 10 November 2020
Resolution: Service tag was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2020
Resolved
Fuel supply hose cracked at fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 November 2020
Resolution: Fuel hose was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 November 2020
Resolved
Bilge pump not properly mounted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2020
Resolution: Bilge pump was renewed and properly mounted in the bilge well.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 10 November 2020
Resolved
Clean bilge well
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 November 2020
Resolution: Bilge well was properly cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2020
Resolved
Install proper battery box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2020
Resolved 16 November 2020
Resolution: Properly installed battery box
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 November 2020
Resolved
Re-mark forward life ring buoy with vessel name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2020
Resolved 16 November 2020
Resolution: Life ring Buoy is properly marked with vessel's name.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 November 2020
Resolved
Seal bow cap screw holes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2020
Resolved 16 November 2020
Resolution: Screw hole are properly sealed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 November 2019
Resolved
Gel-coat cracking at trailer eye bolt and unauthorized repairs on stbd chin.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2019
Resolution: Inspected SAT, re-gel coated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 November 2019
Resolved
Grab line of ring buoy deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2019
Resolution: New ring buoy installed
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 November 2019
Resolved
VHF Radio has feed back while trying to transmit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2019
Resolution: New radio installed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 November 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 December 2019
Resolution: FCC lic. provided to MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2018
Resolved
Steering gear had missing hardware.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2018
Resolved 18 December 2018
Resolution: Accepted documentation satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 December 2018
Resolved
Hardware securing the handrails to deck were found loose in several places onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2018
Resolved 18 December 2018
Resolution: Accepted documentation satisfying the requirement.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 December 2018
Resolved
Provide drug testing and enrollment documentation for employees.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2018
Resolved 18 December 2018
Resolution: Accepted documentation satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2018
Resolved
Steering hose (hydraulic) is damaged.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2018
Resolved 18 December 2018
Resolution: Accepted documentation satisfying the requirement.