VANCOUVER STAR

VANCOUVER STAR is a 2007 freight ship. The Coast Guard has recorded 39 inspections since 2016, most recently in April 2026, along with 29 deficiencies and 12 operational controls.

Records from 2016 to 2026. Most recent: inspection, 8 April 2026.

Built
2007
Last inspected
8 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9322334
V7A7438
931581
Flag
MARSHALL ISLANDS
Maury page id
psix-931581

Documentation record

Tonnage as PSIX records it39906 - Convention (Subpart B), Gross Ton
24504 - Convention (Subpart B), Net Ton
67491 - Displacement, Metric Ton
50532 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 39

8 April 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344738
3 December 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8276756
6 October 2025 PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8247508
10 April 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665568
24 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7656361
15 February 2023 PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7636576
7 February 2023 PSC A · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7632869
16 December 2022 PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7609970
16 December 2022 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7610101
6 December 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7604797
8 August 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7527786
17 March 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7413340
12 March 2022 In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7412088
4 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405932
4 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7405959
14 December 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7368172
29 August 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7301416
7 May 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7191525
3 May 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7187877
15 March 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7156409
19 January 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7126734
19 January 2021 Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7126926
22 November 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7099870
17 November 2020 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7097223
25 September 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7064940
23 September 2020 PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7063415
31 July 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7021207
26 July 2020 PSC A · ISPS Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7016335
26 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7016367
2 June 2020 Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6966421
27 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6961708
8 April 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6937144
1 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6934181
9 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6906857
6 February 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6903915
26 June 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6726595
9 May 2019 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6679386
13 January 2019 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6609693
15 October 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6022835

Deficiency record · 29

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 February 2023 Resolved
Means shall be provided to control leaks of flammable liquids. Piping above generators are soaked in oil. 74SOLAS(04) II-2/4.1.1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
Resolution: Piping above generators cleaned from oil splash residue.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 February 2023 Resolved
Fire-fighting systems and applicances shall be kept in good working order. Multiple CO2 nozzles covered in oil and exhaust. 74SOLAS(04) II-2/14.2.1.2.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2023
Resolution: Crew effectively cleaned CO2 nozzles prior to departure. PSCO cleared deficiency onboard the vessel.
12 - Dangerous Goods › N/A - No Subsystem › Special requirement
Issued 9 February 2023 Resolved
Adequate power ventilation shall be provided in enclosed cargo spaces. During required ISM audit, surveyor discovered inoperable cargo ventilation fans in holds #1, 2, 4, 5, & 7. The crew discovered this condition 1 month ago and did not report to the company. 74SOLAS(20) II-2/19.3.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
Resolution: Statutory Findings issued noting that ventilation in Cargo Holds #2, 4, 5 and 7 is not fully operational and prohibiting the carriage of dangerous goods in those holds. See narrative and documents attached for details.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 9 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea... Lube oil purifier piping leaking steam and water 74SOLAS(20) I/11.a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
Resolution: Leaking steam piping repaired.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 9 February 2023 Resolved
Every ship 100 gross tonnage and above...shall carry a garbage management plan which the crew shall follow. Per the ship's G.M.P., all types of garbage collection receptacles shall be clearly marked with the type of garbage they are receiving. Waste receptacles throughout the ship are not labeled. MARPOL ANN V/10.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2023
Resolution: Waste receptables throughout the ship labeled as requried.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 7 February 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements, which may be established by the company. In meeting these requirements, the company should ensure that: the inspections are held at appropriate intervals; any non-conformity is reported, with its possible cause, if known; appropriate corrective action is taken… Due to the objective evidence in the following deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. PSCOs collected objective evidence that the vessel was not identifying non-conformities and following the inspection and reporting requirements of its SMS. An external audit conducted by a third party is required. Provide a copy of the completed audit report to USCG prior to departure from port. 74 SOLAS (2020 Cons.) IX/3.1 ISM Code Part A 10.1
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 11 February 2023
Resolution: ISM External Audit conducted by LLoyd's Register. 03 Non-Conformities identified with Corrective Action due date 07 MAY 2023. No major non-conformities identified; none downgraded. See attached Audit Report.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 7 February 2023 Resolved
The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. Crew was unable to conduct a function test of the oil content meter due to the system continuously entering error mode. MARPOL Annex I/14.7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 9 February 2023
Resolution: Unit was recalibrated by technician. Crew was able to show proper operation of system.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 February 2023 Resolved
Oil fuel pipes and their valves and fittings shall be of steel or other approved materials. Flexible hose was fabricated to collect leaks on main engine and return back to fuel oil tank. In addition, multiple flexible hoses with fabricated fittings containing oil residues were observed throughout the engine room and a sandpiper pump containing dark oil residues were identified. Chief Engineer stated the pump was used for drills. 74SOLAS(04) II-2/4.2.2.5.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 9 February 2023
Resolution: Class attested to the removal of the flexible hose in question. Sandpiper pump was cleaned. PSCO's could not find evidence that this arrangement was used for anything other than legitimate purposes.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 February 2023 Resolved
Means shall be provided to control leaks of flammable liquids. Lagging on #3 generator, oil purifying room, and various other locations were soaked in oil. 74SOLAS(04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 February 2023
Resolution: Initial rectification actions by vessel were not accepted by PSCO (oil soaked lagging was painted over). During follow up def check PSCO found oil soaked lagging was removed and replaced with new lagging.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 February 2023 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of such a design and construction adequate for the service for which they are intended. #1 and #2 main engine exhaust stack has heat damage and wasted housing. 74SOLAS(04) II-2/26.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 March 2023
Resolution: Recieved and reviewed Flag attestation stating that the main engine housing had been satisfactorily repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 7 February 2023 Resolved
The certificates referred to in this regulation shall be issued or endorsed either by the Administration or by any person or organization authorized by it. In every case, the Administration assumes full responsibility for the certificates. The Cargo Ship Safety Construction Certificate was not endorsed for the inspections of the outside of the ship’s bottom conducted in January 2020. 74SOLAS(20) I/12.a(viii)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2023
Resolution: New certificate was issued to reflect last 2 inspections of the ships bottom.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 7 February 2023 Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without sanction of the administration. Crew fabricated cooling arrangement for emergency air compressor. Additionally, the #2 exhaust of the main engine has been blocked off by a metal plate.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2023
Resolution: Cooling arrangement was removed and exhaust system certified by class as functioning properly.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 February 2023 Resolved
Thermal insulation of boundaries shall have due regard to the fire risk of the space and adjacent spaces. Thermal insulation missing from ceiling of engine room. 74SOLAS(20) II-2/9.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2023
Resolution: Recieved and reviewed Flag attestation stating that the thermal insulation had been satisfactorily repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 7 February 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Steam leak observed on piping near heat exchanger in engine room and secured with rag. 74SOLAS(20) 1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2023
Resolution: Parts on system repaired.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 February 2023 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. Self closing fire door in stairwell on the upper deck failed to close properly. 74SOLAS(20) II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2023
Resolution: Door adjusted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 February 2023 Resolved
Waste recepticles shall be constructed of non-combustable materials. Oily rags were stored in plastic garbage bins through engine room. 74SOLAS(04) II-2/4.4.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2023
Resolution: Plastic garbage bins replaced with appropriate metal bins labeled as required.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 February 2023 Resolved
All steering gear components... shall be of sound and reliable construction to the satisfaction of the Administration. Lubrication pump for steering gear was found secured with twine. 74SOLAS(04) II-1/29.2.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2023
Resolution: Twine was removed and satisfactory steering test was witnessed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 February 2023 Resolved
The date when musters are held, details, of abandon ship drills, and fire drills... shall be recorded in such logbook as may be prescribed by the Administration. Records of fire drills and abandon ship drills are being logged inconsistently between logbook and online database. 74SOLAS(20) III/19
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 February 2023
Resolution: Crew was instructed to log drills in the online database.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 February 2023 Resolved
Each liferaft shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code. Starboard side liferaft hydrostatic release unit expiration date tape was ripped off and missing expiry year. 74SOLAS(20) III/13.4.2
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 7 February 2023
Resolution: Expiration date tape replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 December 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sail without danger to the ship or persons onboard. Vessel experienced a loss of propulsion during inbound transit o the prot o Savannah. SOLAS(20)I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2022
Resolution: Recieved class report attesting to repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 December 2022 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. During a Marine casualty investigation in to a loss of propulsion it was discovered that the vessel cleans fly wheel pick up sensors as a part of maintenance of the ship. Vessel could not provide organizational policy or procedure from the vessels operator that would require the sensors to be cleaned, maintained, or recorded when the crew cleaned the sensors. An external audit is is required within 90 days. SOLAS(20)IX/3 ISM Code 10
Action required: 705 - Other - as specified
Due 16 March 2023
Resolved 7 February 2023
Resolution: Received external audit for ZIM VANCOUVER ISM procedures.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 16 December 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sail without danger to the ship or persons on board. PSCO observed while conducting steering tests that 3 of the 4 rudder angle indicators are showing a difference from actual rudder position by 3 to 5 degrees depending on desired position. SOLAS(20)I/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2022
Resolution: Recieved class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 August 2022 Resolved
If the box containing the controls is to be locked, a key to the box shall be in a break -glass-type enclosure. Lock and key found to be missing on cargo hold control box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2022
Resolved 9 August 2022
Resolution: Following remote examination it is confirmed that the new lock has been instaled, examine as far as practible, and found to be in order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2022 Resolved
01 life buoy self igniting lights did not turn on
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 September 2022
Resolved 8 August 2022
Resolution: vessel installed new buoy self igniting light
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 23 September 2020 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISION OF THE PRESENT CONVENTION TO ENSURE THE SHIP IN ALL RESPECT WILL REMAIN FIT TO PROCEED TO SEA WITHOUT PRESENTING AN UNREASONABLE THREAT OF HARM TO THE ENVIRONMENT. THE OWS CONTENT METER WOULD NOT READ 0 PPM WITH CLEAN WATER EFFLUENT. VESSEL SHALL NOT USE OWS UNTIL CALIBRATED AND ATTESTED BY THE RO.
Action required: 705 - Other - as specified
Resolved 17 November 2020
Resolution: Recieved satisfactory class report attesting to proper repairs
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 July 2020 Resolved
Cargo ships shall carry one or more inflatable or rigid liferaft conforming with the requirements of section 4.2 or 4.3 of the code. The liferaft shall be packed in a container that is as far as practicable watertight. All liferafts onboard vessel have damage to the exterior container affecting watertight integrity. SOLAS CH.III, Reg 31.1.1.2 LSA Code 4.2.6.1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 July 2020
Resolved 27 July 2020
Resolution: New liftrafts brought onboard. Class was notified an was satisfactory with install and arrangement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 July 2020 Resolved
The company and the ship shall comply wit the requirements of the International Safety Management Code. The company should ensure that; any non-comformity is reported with its possible cause if known; appropriate corrective action is taken; and records of these activities are maintained. Liferaft maintenance procedures are not being conducted in accordance with vessel's maintenance program. Life saving equipment non-conformities are not being reported and not recorded in accordance with vessel's SMS. Recommend external ISM Audit.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 26 July 2020
Resolved 27 July 2020
Resolution: Class reviewed SMS. Found no errors.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 9 May 2019 Resolved
Every company and registered owner shall be provided with an identification number which conforms to the IMO unique company and registered owner identification number scheme. Vessel Continuous Synopsis Record listed incorrect owner with non-standard identification number. 74 SOLAS (2014CE) XI-1/3-1.3 Rectify deficiency within 14 days to the satisfaction of the administration and Coast Guard
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 26 June 2019
Resolution: vessel emailed a copy of updated CSR
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 October 2016 Resolved
The fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Fire detection system in cargo holds is inoperable. Vessel has plans to repair system in Savannah.
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 October 2016
Resolved 13 January 2019
Resolution: Repair documentation provided

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.