Records from 2008 to 2023. Most recent: inspection, 5 June 2023.
Documentation record
Registered dimensions (L × B × D)217.0 ft × 42.0 ft × 10.0 ft
Registered tonnagegross 765 / net 765
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD INDUSTRIES INC · MORGAN CITY · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 January 2026 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it765 - Simplified, Gross Ton
765 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
5 June 2023
Examination of Repairs · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7703697
7 April 2021
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7170301
19 July 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6758915
9 July 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6742953
23 May 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6691476
27 April 2018
COI Inspection · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6400490
25 July 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6219992
26 April 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5863320
25 June 2015
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5164006
3 April 2014
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5164228
24 October 2013
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4740346
23 July 2013
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4662281
13 June 2013
MTSA Verification · Internal Structural Exam · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4619285
7 August 2012
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4403655
17 May 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3740442
23 April 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3722971
19 March 2009
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3436335
27 May 2008
Administrative Inspection · Construction Oversight · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3219538
Deck/Cargo › Cargo Heating › General
Issued 27 May 2008
Resolved
Need to Install removable insulation on steam heating system prior to the use of the system. See MSC ltr dated April 16, 2008.
Action required: 705 - Other - as specified
Resolved 19 March 2009
Resolution: steam system insulation provided and installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 May 2008
Resolved
Provide documentation to prove that the fan belt on the cargo pump prime mover is anti-static prior to cargo operations. See MSC ltr dated 1/17/2008.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2009
Resolved 19 March 2009