LR1 CARRIER is a 2007 tank ship. The Coast Guard has recorded 21 inspections since 2016, most recently in October 2025, along with 15 deficiencies and 5 operational controls.
Records from 2016 to 2025. Most recent: inspection, 27 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton 22382 - Convention (Subpart B), Net Ton 73675 - Dead Weight, Metric Ton 89187 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 21
27 October 2025PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8259080
5 August 2024COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7974582
11 April 2024COC-TVE Renew
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7890676
2 November 2023Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7819494
22 September 2023Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7796674
18 July 2023COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7745937
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 July 2023Resolved
09 SOLAS 74 II-2 / 13.3.1.5
DOORS IN ESCAPE ROUTES SHALL BE CAPABLE OF OPING IWO ESCAPE. A METAL DOOR WAS FITTED IN THE MAIN PASSAGEWAY LEADING TO THE MAIN STAIRWELL. THE DOOR WAS CAPABLE OF BEING LOCKED FROM THE MAIN PASSAGWAY BUT NOT UNLOCKED FROM THE MAIN STAIRWELL, AN ESCAPE ROUTE. THE DOOR WAS NOT ADDRESSED IN THE SHIP'S SECURITY PLAN, BUT WAS PUT IN PLACE FOR PIRATES.
Action required: 10 - Deficiency Rectified
Due 19 July 2023
Resolved 19 July 2023
Resolution: DOOR REMOVED
MARPOL ANNEX 1 REG 4.1
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF MARPOL TO ENSURE THE SHIP IS FIT FOR SEA WITHOUT PRESENTING AN UREASONABLE THREAT TO THE ENVIRONMENT. THE CREW DID NOT HAVE THE APPROPRIATE EQUIPMENT TO CONDUCT A TEST OF THE OIL CONTENT METER IAW MANUFACTURER'S INSTRUCTIONS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 August 2023
Resolved 2 November 2023
Resolution: Deficiency Cleared. Class Report received.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 July 2023Resolved
04 SOLAS 74 II-1 / 11(a)
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PUMPROOM FLOOR GRATING HAS BEEN MODIFIED FOR BALLAST PIPING SYSTEM, CAUSING PARTS TO BE UNSTABLE. IN ADDITION, RAILING FOR GENERATORS WERE REMOVED AND NOT AVAILABLE.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 August 2023
Resolved 2 November 2023
Resolution: Deficiency Cleared. Class Report received.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 December 2018Resolved
A tanker with a defective Oil Discharge Monitoring and control system may undertake one ballast voygage before proceeding to a repair port. The ODME has been inoperable since 04NOV2018, completed one ballast voyage to ST. Eustatius and one to New York.
MARPOL Annex 1, Reg 31.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2018
Resolution: Technician attended vessel and repaired necessary equipment. Technician provided report and class certified repairs in class report.
01 - Certificates & Documentation › 013 - Documents › Cargo record book
Issued 1 December 2018Resolved
Every ship shall be provided with a Cargo Record Book. The ship does not have a Cargo Record Book on board.
MARPOL Annex II, Reg 15.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2018
Resolution: Vessel provided Cargo Record book prior to PSC departure.
Oil Tankers shall be subject to an Enhanced Survey program in accordance with the Organization. The vessel does not have an approved Enhanced Survery.
(04)SOLAS CH XI-I, Reg 2.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2018
Resolution: Class attended and approved previous enhanced survery from ABS. Provided class report for attendance and endorsed documentation.
The arrangments for inerting shall be to the satisfaction of the administration. The IGS/IGG manual is not approved. Cargo Operations are denied.
(04)SOLAS II-2, reg 4.5.6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2018
Resolution: Class society attended vessel and approved IGG manual.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 December 2018Resolved
Where cables are installed in hazardous areas that introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risk shall be to the satisfaction of the administration. (02) Grounding wires in Cargo Pump room lighting system are broken. Cargo Operations are denied.
(04) SOLAS II-1, reg 45.5.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2018
Resolution: Electrical officer made necessary repairs and class provided report attesting to repairs in cargo pump room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 December 2018Resolved
The atmosphere in double hull spaces shall be fitted with permanent gas sampling lines. There is a fault on the fixed gas sampling line detection system. Cargo Operations are denied.
(04) SOLAS II-2, reg 4.5.7.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2018
Resolution: Vessel provided letter of dispensation from flag authorizing the vessel to continue sailing with inoperable hydrocarbon gas detection system for ballast tanks. Vessel has a deadline to repair system by 02 January 2019.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 December 2018Resolved
The condition of the ship and its equipment shall be maintained. The #5 cyclinder jacket water seal is leaking.
(04) SOLAS II-1, reg 11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2018
Resolution: Vessel performed repairs on system and class society attested to repairs via class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 December 2018Resolved
The condition of the ship and its equipment shall be maintained. The jacket water temp gauges on cyclinder 1,2,3 are inoperable.
(04) SOLAS II-1, reg 11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2018
Resolution: Vessel replaced gauges with spares and class society attested to repairs via class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 December 2018Resolved
The high level alarm shall be identified with the legend "HIGH LEVEL ALARM" in black letters. The High Level Alarm is marked in red letters.
46 CFR 39.2007(c)(2)
Action required: 10 - Deficiency Rectified
Resolved 1 December 2018
Resolution: Ship re-stenciled in black lettering.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 December 2018Resolved
The tank overfill alarm shall be identified with the legend "TANK OVERFILL ALARM" in black letters. The tank overfill alarm is marked in red letters.
46 CFR 39.2007(d)(2)
Action required: 10 - Deficiency Rectified
Resolved 1 December 2018
Resolution: Ship re-stenciled in black lettering.
Engineering › Compressed Air System (control) › Valve
Issued 20 February 2017Resolved
Valve postion 11 of pneumatic cotnrol system Plate 70311 was causing intermittent fault in the system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2017
Resolution: Recvd Class report. Valve was overhauled with spares onboard.
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 13 January 2016Resolved
Each COTP may order a vessel to operate or anchor in a manner directed when: (c) COTP has determined that such an order is justified in the interest of safety by reason of... other temporary hazardous circumstances, or the condition of the vessel. PSCOs were potentially exposed to benzene during engine room exam. When entering the fuel oil purifier room, PSCOs noticed what looked like steam comi
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 January 2016
Resolution: All piping drain/overflow piping systems and safe operations in oil purifying room. No visible vapors noted. See attached class report.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.