MAURY USCG vessel records
← All vessels

REBEKAH C

REBEKAH C is a 2009 industrial vessel. The Coast Guard has recorded 12 inspections since 2022, most recently in June 2026, along with 19 deficiencies — 3 with no resolution recorded —.

Records from 2022 to 2026. Most recent: inspection, 29 June 2026.

Built
2009
Last inspected
29 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 June 2026
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2022–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9415442
WDM 7306
932660
Flag
UNITED STATES
Maury page id
psix-932660

Documentation record

Registered dimensions (L × B × D)167.4 ft × 34.1 ft × 14.1 ft
Registered tonnagegross 198 / net 134
ITC dimensions (L × B × D)167.4 ft × 34.1 ft × 14.1 ft
ITC tonnagegross 498 / net 149
BuilderC & G BOAT WORKS INC · MOBILE, AL, UNITED STATES · built 2009
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLONG BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 December 2025 · expires 31 January 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it198 - Regulatory (Subpart C or D), Gross Ton
498 - Convention (Subpart B), Gross Ton
134 - Regulatory (Subpart C or D), Net Ton
149 - Convention (Subpart B), Net Ton
260170 - Displacement, Ton
551 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

29 June 2026 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8418711
6 April 2026 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8319383
18 June 2025 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8163345
1 May 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8129194
25 March 2025 Deficiency Check · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8088849
31 October 2024 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8028300
15 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8019384
16 April 2024 MTSA/ISPS Verification · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7896118
9 May 2023 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7684415
19 January 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7597993
14 March 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7411744
3 January 2022 COI Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7375019

Deficiency record · 19

01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 29 June 2026 No resolution recorded
Vessel temporarily installed PAMs unit for current voyage and associated Navy contract. PAMs are portable enclosed spaces and their volumes are subject to inclusion in tonnage. Vessel owner / management is responsible for contacting an authorized measurement organization for a remeasurement determination, except where allowed by a updated tonnage certificate.
Action required: 705 - Other - as specified
Due 15 September 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 April 2026 No resolution recorded
Power operated valves installed to comply with the requirements of this section must meet the following requirements: Valve actuators must be capable of closing the valves under all conditions, except during physical interruption of the power system (for example, from cable breakage or tube rupture). The pneumatic valves for 2 port and 2 stbd storage tanks did not close when actuated. Repair at next drydock.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2027
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 April 2026 No resolution recorded
Particular note must be made of circuits added after the original issuance of the COI. The Commanding Officer, Marine Safety Center (MSC), may approve any arrangement, fitting, appliance, or equipment. During inspection, a deck davit with power supply and crane motor control box was noted added to stbd cargo deck. Cables terminated in a plastic box. Unprotected cable runs over 24" were electrical taped to supports and exposed to elements. Cable runs were only partially enclosed in conduit (with the exposed conduit pointing up which could gather water from elements, and making cables susceptible to physical damage from cargo or personnel). Please provide plans to MSC within 30 days. (email: [email withheld]). Necessary corrective work can be completed by end of dry dock (January 31, 2027) to satisfaction of class society-vessel has machinery notation-and USCG.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2027
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 March 2025 Resolved
At each inspection for certification, periodic inspection, and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition and may require any tests necessary to determine the condition of the equipment. The generator room's fixed fire-extinguishing 30 second time delay activated at 45 seconds when tested. Demonstrate the proper operation of the generator room's fixed fire-extinguishing time delay in accordance with the system's manufacturer's instructions to the satisfaction of the attending USCG Marine Inspector. 46 CFR 91.25.20 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 April 2025
Resolution: Received email coorepsondence from ABS Surveyor [name withheld] stating that he witnessed the vessel's generator room fixed fire extingusihing system time delay activate at 35 seconds when tested IAW the OEM testing procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 25 March 2025 Resolved
Periodic safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electrical power generation and distribution, and emergency internal communications. Test must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. The vessel's crew did not have access the vessel periodic safety test procedures (PSTPs) and therefore could not demonstrate the PSTPs. Demonstrate the vessel's USCG approved PSTPs to the satisfaction of the attending USCG Marine Inspector. 46 CFR 61.40-6
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 10 April 2025
Resolution: Conducted review of PSTPs, shutdowns, and procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025 Resolved
At least two lifebuoys, each with attached self-activating smoke signals, must be stowed where they can be quickly released from the navigating bridge and should, when released, fall directly into the water without striking any part of the vessel. The vessel's lifebuoys with attached self-activating smokes signals are not stowed to fall directly into the water when released. Stow the lifebuoys with attached self-activating smoke signals to ensure they fall directly into the water, when released, to the satisfaction of the attending USCG Marine Inspector. 46 CFR 199.70 (a) (1) (v)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 15 April 2025
Resolution: Two lifebuoys were installed on the navigating brige wings and were confirmated to fall directly into the water when released.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 25 March 2025 Resolved
Each immersion suit must be marked in such a way as to identify the person or vessel to which it belongs. One immersion suit is marked with a different vessel's name. Mark the immersion suit with the vessel's name. 46 CFR 199.70 (c) (3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 2 April 2025
Resolution: The immersion suit was marked with the vessel's name.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 25 March 2025 Resolved
Each oil tanker of 150 gross tons and above, ship of 400 gross tons and above other than an oil tanker, and manned fixed or floating drilling rig or other platform shall maintain an Oil Record Book Part I. The required entries to the Oil Record Book as detailed in the list of items to be recorded "Part I- Machinery Space Operations" were not being recorded. Enter the required entries into the Oil Record Book Part I from the date of this deficiency. 33 CFR 151.25 (a)
Action required: 10 - Deficiency Rectified
Due 25 March 2025
Resolved 25 March 2025
Resolution: Conducted training and guidance of ORB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 April 2024 Resolved
Prove proper operation of vessel's OWS. Demonstrate ability of OCM to alarm and change flow of water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Witnessed satisfactory operation of OWS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 16 April 2024 Resolved
Provide approval for vessel's PSTP's. Update as needed for new generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 15 April 2025
Resolution: Approved PSTPs were provided and updated procedures were confirmed to have been submitted to the Marine Safety Center.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 April 2024 Resolved
Submit weight changes to MSC for new generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 15 April 2025
Resolution: Received documenation that the required weight change information was submitted to the Marine Safety Center.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
Provide engine room electrical panels P-1 and P-2 with proper closing latches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Received photo of latches installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2024 Resolved
Conduct machinery alarms/shutdowns per PSTP's on all main engines and generators. 21MAY2024: Conducted PSTP on generators. Shutdowns SAT. Alarms were inop. CO2 Shutdowns INOP. Follow on inspection required. Sent email to POC for clarification on PSTP submitted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 4 June 2024
Resolution: Witnessed sat test of all machinery alarms & CO2 shutdowns.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
Makes repairs to broken electrical emergency light in the truster compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 1 May 2024
Resolution: Recieved photo of corrected light fixture.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 19 January 2023 Resolved
Every vessel shall carry at least two firemen's outfits. Vessel is not equipped with firemen's outfits. Equip vessel with a minimum of two firemen's outfits, with all equipment required by 46 CFR 96.35. Vessel is restricted from conducting international voyages until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 21 March 2023
Resolution: Verified o/b vessel...[name withheld]
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 19 January 2023 Resolved
OWS inoperable-vessel required to retain all bilge/dirty oil water onboard and may not discharge until proved operation of OWS. IOPP void if not repaired within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 21 March 2023
Resolution: Verified operation o/b vessel...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2023 Resolved
Freezer boxes on main deck installed with extension cords, must provide long electrical cords or install outlets closer to the boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2023
Resolved 15 February 2023
Resolution: Pics sent to OCMI...[name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 January 2023 Resolved
Must install 30x30 mesh flame screen on vent pipe for #3 fuel tank port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 1 February 2023
Resolution: Pics sent to OCMI...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2023 Resolved
Must repair or replace explosion proof light cover over port side generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2023
Resolved 25 January 2023
Resolution: Light cover was replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.