Records from 2009 to 2026. Most recent: inspection, 10 February 2026.
Inspection history · 75
10 February 2026
Annual Inspection · ACP Annual Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8310165
4 November 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8264333
2 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151324
14 April 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8111800
16 March 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8094643
24 June 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7941697
13 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7942430
9 January 2024
Re-Inspection · Deficiency Check · MTSA/ISPS Verification · ACP COI Oversight · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7847409
4 May 2023
ACP Annual Oversight · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7679525
10 March 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7648698
13 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608723
28 November 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7600737
22 November 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601367
2 November 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7588483
11 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7531026
7 April 2022
ACP Periodic Oversight · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7430500
27 March 2022
Type not recorded
No type recorded · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7421500
6 October 2021
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7328067
14 June 2021
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7225207
14 April 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7175126
12 January 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7126874
5 July 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7008681
23 May 2020
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6958777
23 May 2020
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6963886
20 April 2020
Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6942098
10 March 2020
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6923795
13 January 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6890097
4 October 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830772
2 March 2019
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6636023
8 February 2019
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6618065
19 April 2018
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6392804
13 February 2018
Spot Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6364377
2 December 2017
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6318958
5 September 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6281139
17 May 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6215295
26 April 2017
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131417
23 March 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6109750
23 January 2017
Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6077013
19 November 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6045606
18 November 2016
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6045552
2 November 2016
Internal Structural Exam · Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6034634
20 July 2016
Bulk Liquid Transfer Monitor
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5946676
5 February 2016
ACP Annual Oversight
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5811434
25 August 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4965981
20 March 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4820679
20 March 2014
Examination of Repairs · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4822654
17 March 2014
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4822739
14 March 2014
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4817552
14 March 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4817908
26 June 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4357195
11 May 2012
ISPS II Exam · ACP Annual Oversight
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4312084
8 February 2012
Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4240723
25 January 2012
Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4232606
19 January 2012
Damage Survey
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4227856
24 December 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4213724
7 December 2011
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4203997
16 July 2011
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4087607
17 February 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3947227
10 February 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3947385
11 January 2011
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3925022
19 November 2010
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3895045
15 November 2010
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3892034
16 September 2010
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3853698
30 March 2010
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3707099
23 March 2010
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3702306
14 March 2010
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3701425
8 March 2010
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3692057
26 January 2010
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3670319
23 December 2009
Deficiency Check
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3654684
29 April 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3474437
10 April 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3450071
7 April 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3448305
24 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3439121
21 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3437714
27 January 2009
MARPOL Annex VI Survey · Initial Certification · Construction Oversight · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3400733
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2026
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. Turbo Charger Lube Oil Cooler found leaking.
SOLAS II-2/4.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2026
Resolved 2 March 2026
Resolution: Deficiency accepted by RO and confirmed as completed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 February 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vent duct supply for purifier room found with suspected deterioration/small fracture.
SOLAS I/11
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2026
Resolved 2 March 2026
Resolution: Deficiency accepted by RO and confirmed as completed.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 10 February 2026
Resolved
se or storage of extinguishing media containing perfluorooctane sulfonic acid (PFOS) shall be prohibited. Vessel did not have evidence showing onboard fixed foam is free of PFOS.
SOLAS II-2/10.11.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2026
Resolved 2 March 2026
Resolution: Deficiency accepted by RO and evidence was provided for foam compliance.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 February 2026
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the doors shall be self-closing. The following fire screen doors did not fully self-close: door on A deck stairway and all four galley access doors.
74 SOLAS (09) II-2/9.4.1.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2026
Resolved 2 March 2026
Resolution: Deficiency accepted by RO and confirmed as completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2026
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Dead end wires noted on the forward upper corner on either side of bulkhead stuffing tube on starboard bridgewing.
74 SOLAS (04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 February 2026
Resolution: Crew corrected in presence of MI by capping wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 November 2025
Resolved
All lifeboats shall be of sufficient strength to: enable them to be safely launched into the water when loaded with their full complement of persons and equipment. Lifeboat aft door does not supply sufficient strength to be watertight due to one of dogs being broken.
74 SOLAS 2020/III.34
LSA Code 2024 Ch.4.4.1.3
17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2025
Resolved 6 November 2025
Resolution: Repaired via new fabricated aluminum mount provided by Motive Power Marine. See ABS finding number 941.0
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 April 2025
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers.. unless the Administration is satisfied that such equipment is: appropriate to the space concerned. MI found damaged intrinsically safe light at the oxygen/acetylene storage space. 74SOLAS(04)II-1/45.10.3
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2025
Resolution: ABS accepted referred deficiency and provided report detailing rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 24 June 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel reported fast rescue boat as being inoperable since the previous port. 74 SOLAS (20) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2024
Resolved 27 June 2024
Resolution: Replaced engine management module, spark plug, kill switch, and ignition coil. Confirmed operational by class.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 2 November 2022
Resolved
On each tanker 10000 GT or more that is subvject to 46 USC 3708, the dual radar system that is required by this part must have short range and long range capability. Vessel's X band radar is inoiperable. Provide technician report proving radar is fully operational.
33CFR164.37
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2022
Resolution: Vessel provided tech report showing that X band radar is fully functional. Uploaded into Documents.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 7 April 2022
Resolved
The person in charge shall restrict access to regulated areas to persons wearing an appropriate respirator. It was observed that the personnel involved connecting the loading arms were not wearing respirators. The vessel’s SMS (4.6.1) states “any vessel or shore personnel involved with connecting/disconnecting hose/arms” is a regulated area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 11 August 2022
Resolution: Received, reviewed, and accepted ABS Class Report addressing use of PPE IAW the SMS. Internal CAR created by vessel IAW SMS procedures and will be reviewed at next external audit. Uploaded report to Deficiency Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 7 April 2022
Resolved
Load shedding or equivalent arrangement shall be provided to protect the generators required by this regulations. On 27MARrch2002 the vessel experienced a "black-out" condition. The SSDG breakers were retrofitted with new breakers. Provide a review and approval of the retrofit from ABS and prove proper operation by ABS witnessing the design verification test procedures. SOLAS II-1/41
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2022
Resolved 11 August 2022
Resolution: Received, reviewed, and accepted Class Report addressing the DVTPs for the new breakers. Class Report uploaded in deficiency documents.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 April 2020
Resolved
The M/T OVERSEAS BOSTON (ON 1207239, 576 FT, 29242 GT, Tanker) has a pin hole leak in the anchor windlass hydraulic system. The casualty prevents the vessel from weighing anchor until a piece of piping is repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2020
Resolved 22 April 2020
Resolution: Repair Completed.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 20 March 2014
Resolved
Provide report attesting to cause of fuel pump failures reported to Sectors LA/LB, San Fran, and Puget Sound (Feb-March). 46CFR31.10-25.
Action required: 705 - Other - as specified
Due 5 May 2014
Resolved 1 May 2014
Resolution: 01MAY13: Vessel switched to using only OEM fuel pump parts due to history of failures. Failure analysis no longer necessary.
Engineering › Steering Gear System › Rudder Bearing
Issued 8 February 2012
Resolved
During vessel UWILD divers were unable to remove access door for the lower pintle bearing. Vessel is in the ACP program, a work list item was issued to complete inspection at next available dock side no later than 09 April 2012.
On 19 March 2012 Coast Guard received written request to defer final part of UWILD until NLT 30 April 2012. OCMI has allowed extension until then.
Due 30 April 2012
Resolved 28 April 2012
Resolution: ABS Class Surveyor attended vessel and cleared above CG 835.
Navigation › Voyage Data Recorder › Voyage Data Recorder (VDR)
Issued 19 January 2012
Resolved
Replace/repair VDR.
Action required: 705 - Other - as specified
Due 31 January 2012
Resolved 25 January 2012
Resolution: VDR repaired.
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 December 2011
Resolved
24DEC2011 - Letter of Deviation issued due to an inoperable S.Band (10cm) Radar. Repairs to be completed in Port of Los Angeles / Long Beach
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2011
Resolution: Received Tech Report attesting to repairs of Radar, and confirmation in good working order and worthy for Navigation.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 December 2009
Resolved
Ship's crew found OWS inoperable during monthly check and reported to CG
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 January 2010
Resolved 5 January 2010
Resolution: Received Classification Report from ABS stating proper repairs have been made to the OWS and operational testing of the equipment was satisfactory to the attending surveyor.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 27 January 2009
Resolved
Prior to operation of the incinerator show proper thermal capability (600 degree C with in first 5 minutes) to attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: Witnessed satisfactory test of incinerator.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 27 January 2009
Resolved
Provide paperwork / documents required for CG type approval for incinerator in accordance with MEPC 76(40) / MARPOL VI compliance to USCG Marine Safety Center, 1900 Half St SW Suite 1000, Rm 525 Washington DC 20593 with in 60 days.
Action required: 705 - Other - as specified
Due 20 April 2009
Resolved 6 April 2009
Resolution: Received compliance documentation.