QUEEN VICTORIA is a 2007 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2007, most recently in January 2025, along with 31 deficiencies and 1 operational control.
Records from 2007 to 2025. Most recent: inspection, 20 January 2025.
- Built
- 2007
- Last inspected
- 20 January 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 31 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9320556 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZCEF3
932774
Flag
BERMUDA
—
Maury page id
psix-932774
Inspections, by type
…with no type recorded5
Years with a record
14 calendar years (2007–2025)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it90746 - Convention (Subpart B), Gross Ton
50618 - Convention (Subpart B), Net Ton
7700 - Dead Weight, Ton
43533 - Displacement, Ton
50618 - Convention (Subpart B), Net Ton
7700 - Dead Weight, Ton
43533 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
20 January 2025
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8064752
7 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7862137
17 January 2024
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7850436
20 January 2023
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7622182
29 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7067613
20 January 2020
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6886458
12 February 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6624790
5 February 2019
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6620203
20 January 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6607263
10 March 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6369435
17 January 2018
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6335378
15 January 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6068650
12 February 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5814130
7 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5842801
20 January 2016
COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5800234
4 January 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4218310
21 December 2011
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4211128
21 December 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4234795
6 December 2011
ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4201830
18 December 2010
COC-CVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3914218
27 January 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3670758
12 January 2010
PII Safety Exam · Ballast Water Examination · COC-CVE Annual · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3660741
27 February 2009
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3427246
9 January 2009
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3391249
13 January 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3129486
27 November 2007
PII Safety Exam · COC-CVE Annual · MARPOL Annex V Examination · Ballast Water Examination · COC-CVE Initial · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 3105052
Deficiency record · 31
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 January 2025
Resolved
07123 - Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Smoke Detector #42-34 was found not operational and unable to detect smoke.
74 SOLAS 20 II-2/14.1.1
10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2025
Resolved
07105 - The construction of doors and door frames in 'A' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire doors 0A.4.38, 08.4.17, 08.1.56 did not latch properly.
74 SOLAS 20 II-2/9.4.1.1.2
10c
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 January 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Multiple fire doors on deck "A" that were located on main vertical zones and leading to stairways were found not able to be self-closing. FSD 03.3.45, A.2102, A.3.91, and A645.
74 SOLAS 20 II-2/9.4.1.1.5.1
10c
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 January 2024
Resolved
Damper controls shall be easily accessible as well as prominently and permanently marked and shall indicate whether the shut-off is open or closed. Approximately 18 fire damper remote-control indicators in the engine room displayed "failure" or did not have operable lights indicating whether the dampers were open or closed. Vessel provided evidence that dampers were functional, and this was able to be visually verified from the ECR.
74 SOLAS (04) II-2/9.7.3.2
16ac
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 January 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed multiple lifeboat crew members unfamiliar with location of safety equipment and unfamiliar with general operation of vessel equipment.
74 SOLAS 20 III/19.1
40c
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2020
Resolved
07109 - A fixed fire extinguishing systems may be a fixed pressure water spraying system complying with the FSS code. Each section of sprinklers shall include means for giving alarm whenever any sprinkler comes into operation. Such unit shall indicate in which section served by the system a fire has occurred. Bridge section valve indicating system does not identify which section has been activated. Cite: SOLAS 09 II-2/10.6.1.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2020
Resolved
07120 - In addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape, including stairways and exits shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points along the escape route. Low Location Lighting (LLL) blocked by various portable tanks and totes outside the garbage room located on the bulkhead deck. LLL blocked by furniture on deck 12 stairtower lobby. Cite: SOLAS 09 II-2/13.3.2.5.1
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2020
Resolved
07120 - The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. Escape routes shall be maintained in a safe condition, clear of obstacles. The starboard side door in the vessel's fitness center, which is part of an escape route is unable to be opened, and stuck. PSCO observed an A-60 FSD 01.6.08 partially blocked by a tool chest backstage in the main theater. Cite: SOLAS 09 II-2/13
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2020
Resolved
07105 - Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the approximate closure time for hinged doors shall be no more than 40 s and no less than 10 s from teh beginning of their movements. PSCOS's observed the following fire screen doors closing faster than the appropriate time: FSD 09.6.01, FSD 03.4.41. Cite: SOLAS 09 II-2/9
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 20 January 2020
Resolved
07104 - Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures other than power-operated watertight doors shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. The following FSD's failed to properly close and latch during the main vertical zone closure test; FSD 01.6.16, 07.6.03, 07.6.07. PSCO's observed the following FSD improperly latched; FSD 01.1.80. Cite: SOLAS 09 II-2/9.4.1.1.4
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2020
Resolved
07120 - Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power required by regulation II-1/42 or II-1/43, as appropriate. PSCO's observed inoperable lighting on the embarkation deck in the vicinity of lifeboats 4 & 10. Lighting was also inoperable in the grand lobby deck 3 forward, and AC station 5308 aft center bulkhead. Cite: SOLAS 14 III/11.4
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 January 2020
Resolved
07199 - Waste receptacles shall be constructed of non-combustible materials with no opening in the sides or bottom. PSCO's observed combustible (plastic) waste receptacles containing combustible materials (paper products) in the garbage room on the bulkhead deck. Cite: SOLAS 09 II-2/4.2
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 12 February 2019
Resolved
While ships are operating within an emission control area, the Sulphur content of fuel oil used on board ships shall not exceed the following limits: 0.10% m/m on and after 1 January 2015. Vessel's exhaust gas scrubber system allowed by Regulation 4 & RO, lost suction to sea water due to high winds and ship list, resulting in exhaust gas emissions of 1.85% on two incidents totaling 92 minutes while within North American ECA.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2019
Resolved
Fire door approximate time of closure shall be no more than 40s and less than 10s. The following fire doors did not meet the standard: A.2.102, A.2.99, 01.6.06, 01.7.03, 03.1.69, 03.1.96, 03.2.82, 09.6.07, 08.3.58
74 SOLAS 09 Cons CH II-2/ Reg 9.4.1.1.4.2
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 January 2019
Resolved
Fire safety systems shall be maintained and ready for use. Upon inspection of the fire main, a pin hole was discovered in the discharge piping for the forward emergency fire pump.
74 SOLAS 09 Cons CH II-2/ Reg 14.1.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2019
Resolved
Fire safety systems shall be maintained and ready for use. Upon inspection of the fixed high fog system the following high fog head nozzles were found damaged, cold room 11 and cold room 12.
74 SOLAS 09 Cons CH II-2/ Reg 14.1.1
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2019
Resolved
Fire doors shall be self closing. The following fire doors were found blocked by obstructions. Fire door 03.2.78 in the upper bell box galley forward and 01.6.08 starboard side behind theater store room.
74 SOLAS 09 Cons CH II-2/ Reg 9.4.1.1.4.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 January 2019
Resolved
Fire detection systems shall be kept in good working order. Heat detector in garbage room cold stores was found to be not operational.
74 SOLAS 09 cons CH II-2/ Reg 14.2.1.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2019
Resolved
The construction of doors and door frames in A class divisions shall provide resistance to fire as well as the passage of smoke and flame. Firs door 3.4.484 was found to not meet the standard due to poor condition.
74 SOLAS 09 cons CH II-2/ Reg 9.4.1.1.2
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2019
Resolved
Escape routes shall be clear of obstacles. Emergency Escape in chops grill, deck 10 aft starboard is blocked by dining tables and chairs.
74 SOLAS 09 cons CH II-2/ Reg 13.1.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 January 2019
Resolved
Waste receptacles shall be constructed of non-combustible materials. Paper waste in deck 9 galley washroom s contained in combustible plastic trash bins. Lower main galley deck 2.
74 SOLAS 09 cons CH II-2/ Reg 4.4.2
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 January 2019
Resolved
The load line mark shall be painted in white on a dark ground. The ground is red in color with the ring, lines and letters being mostly red.
ICLL CH.1 Reg 8
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 17 January 2018
Resolved
Means shall be provided to control leaks of flammable liquids. Excessive fuel leaks were observed at fuel pump number 4 on diesel generator 4, fuel line to pressure sensor on Diesel generator 6, and fuel pump 2 on diesel generator 6. 74 SOLAS (09 Cons.) II-2/4.1.1
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 January 2018
Resolved
The approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of thier movement with the ship in an upright position. Fire screen doors 8.5.14,8.3.27,9.2.48,9.3.33,9.6.06,10.3.24,02.5.53 were observed to not close within the regulatory required time frames. 74 SOLAS (09 Cons.) II-2/9.4.1.1.4.2
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 17 January 2018
Resolved
A fixed fire extinguishing system may be a fixed pressure water spraying system complying with the FSS code. Each section of sprinklers shall include means for giving alarm whenever any sprinkler comes into operation. Such unit shall indicate in which section served by the system a fire has occured. Bridge section valve indicating system does not identify which section has been activated. 74 SOLAS (14 Cons) II-2/10.4.3, FSS Code 8.2.5.2.1
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 January 2016
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators. Deck A from MVZ 3 AFT does not have means installed.
Fire Fighting › Structural - B Class Divisions › Cabin Doors
Issued 6 December 2011
Resolved
0710 - Fire Prevention: Cabin doors in "B" class divisions shall be self closing type. Hold-back hooks are not permitted. Found numerous cabin doors with closing mechanism disconnected as well as cabin doors held open by wedges. SOLAS 2004 Reg II-2 Reg 9.4.1.2.2.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 6 December 2011
Resolved
0710 - Fire prevention: Was receptacles shall be constructed of non-combustible materials with no openings on the sides or bottom. Found several plastic waste receptacles being used for disposal of paper and other combustible materials throughout the ship (Garbage room, galleys, etc.) SOLAS 2004 II-2 Reg 4.4.2
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 6 December 2011
Resolved
0750 - Fire prevention: Where the contents of a space and its use are such that there is a doubt to classification, it shall be treated as a space within the relevant category having the most stringent requirements. Excessive combustibles stored in cable store below tech store 4 D-deck. Also found excessive flammable liquids in aft auxiliary room on D-deck (Cat 11). 2004 SOLAS II-2 Reg 9.2.2.3.2.2
Fire Fighting › Structural - A Class Divisions › Doors
Issued 6 December 2011
Resolved
0710 - Fire prevention: Openings in "A" class divisions shall be provided with permanently attached means of closing. Found more than 18 Fire Screen Doors that would not fully close and/or had problems with sequencing of closure. A list of affected doors was provided to vessel. SOLAS 2004 II-2 Reg 9.4.1.1.1.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 January 2008
Resolved
Provide copy of approved Fire Control Plans to US Coast Guard Marine Safety Center for their review.