Records from 2016 to 2025. Most recent: inspection, 20 January 2025.
Inspection history · 15
20 January 2025
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8064752
7 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7862137
17 January 2024
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7850436
20 January 2023
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7622182
29 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7067613
20 January 2020
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6886458
12 February 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6624790
5 February 2019
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6620203
20 January 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6607263
10 March 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6369435
17 January 2018
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6335378
15 January 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6068650
12 February 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5814130
7 February 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5842801
20 January 2016
COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5800234
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 January 2025
Resolved
07123 - Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Smoke Detector #42-34 was found not operational and unable to detect smoke.
74 SOLAS 20 II-2/14.1.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2025
Resolved 20 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2025
Resolved
07105 - The construction of doors and door frames in 'A' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Fire doors 0A.4.38, 08.4.17, 08.1.56 did not latch properly.
74 SOLAS 20 II-2/9.4.1.1.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 January 2025
Resolved 20 January 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 January 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. Multiple fire doors on deck "A" that were located on main vertical zones and leading to stairways were found not able to be self-closing. FSD 03.3.45, A.2102, A.3.91, and A645.
74 SOLAS 20 II-2/9.4.1.1.5.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 21 January 2024
Resolved 21 January 2024
Resolution: Doors were repaired before team departure.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 January 2024
Resolved
Damper controls shall be easily accessible as well as prominently and permanently marked and shall indicate whether the shut-off is open or closed. Approximately 18 fire damper remote-control indicators in the engine room displayed "failure" or did not have operable lights indicating whether the dampers were open or closed. Vessel provided evidence that dampers were functional, and this was able to be visually verified from the ECR.
74 SOLAS (04) II-2/9.7.3.2
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2024
Resolved 7 February 2024
Resolution: Received class repor from LR, stating that repairs were complete.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 January 2024
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed multiple lifeboat crew members unfamiliar with location of safety equipment and unfamiliar with general operation of vessel equipment.
74 SOLAS 20 III/19.1
40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 January 2024
Resolved 24 January 2024
Resolution: Vessel sent training schedule and training with valid documentation for all crew members.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2020
Resolved
07109 - A fixed fire extinguishing systems may be a fixed pressure water spraying system complying with the FSS code. Each section of sprinklers shall include means for giving alarm whenever any sprinkler comes into operation. Such unit shall indicate in which section served by the system a fire has occurred. Bridge section valve indicating system does not identify which section has been activated. Cite: SOLAS 09 II-2/10.6.1.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2020
Resolved
07120 - In addition to the emergency lighting required by regulations II-1/42 and III/11.5, the means of escape, including stairways and exits shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points along the escape route. Low Location Lighting (LLL) blocked by various portable tanks and totes outside the garbage room located on the bulkhead deck. LLL blocked by furniture on deck 12 stairtower lobby. Cite: SOLAS 09 II-2/13.3.2.5.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2020
Resolved
07120 - The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. Escape routes shall be maintained in a safe condition, clear of obstacles. The starboard side door in the vessel's fitness center, which is part of an escape route is unable to be opened, and stuck. PSCO observed an A-60 FSD 01.6.08 partially blocked by a tool chest backstage in the main theater. Cite: SOLAS 09 II-2/13
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2020
Resolved
07105 - Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: the approximate closure time for hinged doors shall be no more than 40 s and no less than 10 s from teh beginning of their movements. PSCOS's observed the following fire screen doors closing faster than the appropriate time: FSD 09.6.01, FSD 03.4.41. Cite: SOLAS 09 II-2/9
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 20 January 2020
Resolved
07104 - Fire doors in main vertical zone bulkheads, galley boundaries, and stairway enclosures other than power-operated watertight doors shall be self-closing and capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. The following FSD's failed to properly close and latch during the main vertical zone closure test; FSD 01.6.16, 07.6.03, 07.6.07. PSCO's observed the following FSD improperly latched; FSD 01.1.80. Cite: SOLAS 09 II-2/9.4.1.1.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2020
Resolved
07120 - Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power required by regulation II-1/42 or II-1/43, as appropriate. PSCO's observed inoperable lighting on the embarkation deck in the vicinity of lifeboats 4 & 10. Lighting was also inoperable in the grand lobby deck 3 forward, and AC station 5308 aft center bulkhead. Cite: SOLAS 14 III/11.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 January 2020
Resolved
07199 - Waste receptacles shall be constructed of non-combustible materials with no opening in the sides or bottom. PSCO's observed combustible (plastic) waste receptacles containing combustible materials (paper products) in the garbage room on the bulkhead deck. Cite: SOLAS 09 II-2/4.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2020
Resolution: Vessel provided Flag documentation attesting to corrected deficiency.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 12 February 2019
Resolved
While ships are operating within an emission control area, the Sulphur content of fuel oil used on board ships shall not exceed the following limits: 0.10% m/m on and after 1 January 2015. Vessel's exhaust gas scrubber system allowed by Regulation 4 & RO, lost suction to sea water due to high winds and ship list, resulting in exhaust gas emissions of 1.85% on two incidents totaling 92 minutes while within North American ECA.
Action required: 10 - Deficiency Rectified
Due 12 February 2019
Resolved 12 February 2019
Resolution: Vessel corrected ECA violation as they noticed it, ie immediately.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2019
Resolved
Fire door approximate time of closure shall be no more than 40s and less than 10s. The following fire doors did not meet the standard: A.2.102, A.2.99, 01.6.06, 01.7.03, 03.1.69, 03.1.96, 03.2.82, 09.6.07, 08.3.58
74 SOLAS 09 Cons CH II-2/ Reg 9.4.1.1.4.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2019
Resolution: All fire door closure times fell within the normal range
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 January 2019
Resolved
Fire safety systems shall be maintained and ready for use. Upon inspection of the fire main, a pin hole was discovered in the discharge piping for the forward emergency fire pump.
74 SOLAS 09 Cons CH II-2/ Reg 14.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 January 2019
Resolved
Fire safety systems shall be maintained and ready for use. Upon inspection of the fixed high fog system the following high fog head nozzles were found damaged, cold room 11 and cold room 12.
74 SOLAS 09 Cons CH II-2/ Reg 14.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 January 2019
Resolution: High Fog Head was changed out
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2019
Resolved
Fire doors shall be self closing. The following fire doors were found blocked by obstructions. Fire door 03.2.78 in the upper bell box galley forward and 01.6.08 starboard side behind theater store room.
74 SOLAS 09 Cons CH II-2/ Reg 9.4.1.1.4.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 January 2019
Resolution: Items preventing doors from being self closing were removed from the path of the door.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 January 2019
Resolved
Fire detection systems shall be kept in good working order. Heat detector in garbage room cold stores was found to be not operational.
74 SOLAS 09 cons CH II-2/ Reg 14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2019
Resolution: Heat detector in the garbage room cold store was operationsl
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 January 2019
Resolved
The construction of doors and door frames in A class divisions shall provide resistance to fire as well as the passage of smoke and flame. Firs door 3.4.484 was found to not meet the standard due to poor condition.
74 SOLAS 09 cons CH II-2/ Reg 9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 February 2019
Resolution: Fire door 3.4.484 was fixed and met the standards of the regulation
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 January 2019
Resolved
Escape routes shall be clear of obstacles. Emergency Escape in chops grill, deck 10 aft starboard is blocked by dining tables and chairs.
74 SOLAS 09 cons CH II-2/ Reg 13.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 January 2019
Resolution: Blocked pathways were removed of obstructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 January 2019
Resolved
Waste receptacles shall be constructed of non-combustible materials. Paper waste in deck 9 galley washroom s contained in combustible plastic trash bins. Lower main galley deck 2.
74 SOLAS 09 cons CH II-2/ Reg 4.4.2
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2019
Resolution: Waste receptacles have been replaced with non-combustible metallic receptacles
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 January 2019
Resolved
The load line mark shall be painted in white on a dark ground. The ground is red in color with the ring, lines and letters being mostly red.
ICLL CH.1 Reg 8
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 February 2019
Resolution: Load line currently meets the regulation
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 17 January 2018
Resolved
Means shall be provided to control leaks of flammable liquids. Excessive fuel leaks were observed at fuel pump number 4 on diesel generator 4, fuel line to pressure sensor on Diesel generator 6, and fuel pump 2 on diesel generator 6. 74 SOLAS (09 Cons.) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 17 January 2018
Resolution: Fuel leaks corrected on the spot.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 January 2018
Resolved
The approximate time of closure for hinged fire doors shall be no more than 40s and no less than 10s from the beginning of thier movement with the ship in an upright position. Fire screen doors 8.5.14,8.3.27,9.2.48,9.3.33,9.6.06,10.3.24,02.5.53 were observed to not close within the regulatory required time frames. 74 SOLAS (09 Cons.) II-2/9.4.1.1.4.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 January 2018
Resolved 17 January 2018
Resolution: All fire doors were sequenced and operating correctly.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 17 January 2018
Resolved
A fixed fire extinguishing system may be a fixed pressure water spraying system complying with the FSS code. Each section of sprinklers shall include means for giving alarm whenever any sprinkler comes into operation. Such unit shall indicate in which section served by the system a fire has occured. Bridge section valve indicating system does not identify which section has been activated. 74 SOLAS (14 Cons) II-2/10.4.3, FSS Code 8.2.5.2.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 March 2018
Resolved 9 February 2018
Resolution: Received Tech and Class report attesting to repairs. Entered into MISLE
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 January 2016
Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators. Deck A from MVZ 3 AFT does not have means installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 February 2016
Resolved 12 February 2016
Resolution: Received email and photos attesting to rectification of deficiency.