MAURY USCG vessel records
← All vessels

SICHEM BEIJING

SICHEM BEIJING is a 2007 tank ship. The Coast Guard has recorded 3 inspections since 2017, most recently in April 2019, along with 4 deficiencies.

Records from 2017 to 2019. Most recent: inspection, 2 April 2019.

Built
2007
Last inspected
2 April 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2019
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9397042
932829
Flag
BERMUDA
Maury page id
psix-932829

Documentation record

Tonnage as PSIX records it8627 - Convention (Subpart B), Gross Ton
4117 - Convention (Subpart B), Net Ton
13068 - Dead Weight, Ton
17472 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

2 April 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6654112
4 April 2018 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6379027
25 March 2017 Deficiency Check · COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6113284

Deficiency record · 4

Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 4 April 2018 Resolved
Controlled tank venting systems shall consist of a primary and a secondary means of allowing full flow relief of vapor to prevent over-pressure or under-pressure in the vent of failure of 1 means. Alternatively, the secondary means may consist of pressure sensors fitted in each tank with a monitoring system in CCR. Such monitoring equipment shall also provide an alarm facilit which is activated by detection of overpressure or under-pressure conditions within a tank. PCBs for tanks slop P and slop S have malfunctioned, and therefore pressure alarms for these tanks currently are not functional (vessel uses pressure sensors and alarms as secondary mans to prevent over and under pressure). 74 SOLAS 14 VII/10.1 REF IB 8.3.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 15 May 2018
Resolution: Received class (ABS) report stating that both PCBs have been replaced and tested satisfactorily.
Deck/Cargo › Cargo Stowage › General
Issued 4 April 2018 Resolved
The cargo sample stowage space shall be cell-divided in order to avoid shifting of the bottles at sea. PSCOs found multiple cargo sample bottles not cell-divided and with not legible markings.
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: All samples were properly stowed and labeled to satisfaction of attending PSCOs prior to completion of exam.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 25 March 2017 Resolved
SELF-PROPELLED VESSELS WITH 250 GALLONS OR MORE OF OIL OR HAZARDOUS MATERIAL CONDUCTING TRANSFER OPERATIONS BETWEEN SUNSET AND SUNRISE MUST HAVE DECK LIGHTING THAT ADEQUATELY ILLUMINATES TRANSFER WORK AREA AND TRANSFER POINT. PSCOS OBSERVED 11 OF 20 DECK LIGHTS INOPERABLE. 33CFR155.790. 40AC.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2017
Resolution: Agent submitted class report detailing satisfactory test witnessed by ABS surveyors.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 25 March 2017 Resolved
PRESENCE AND OPERABILITY OF AN INCINERATOR MAY BE CONSIDERED BY ENFORCEMENT PERSONNEL IN EVALUATING THE VESSEL'S COMPLIANCE. PSCOS OBSERVED INOPERABLE INCINERATOR AND TECHNICIAN ONBOARD. 33CFR151.63(b)(3). 40AC.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 March 2017
Resolution: Agent submitted class report detailing satisfactory test witnessed by ABS surveyors.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.