Records from 2008 to 2026. Most recent: inspection, 6 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 57
6 April 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8343427
2 March 2026
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 8318700
5 February 2026
MTSA/ISPS Verification · Administrative Inspection · Periodic Inspection · MSP Periodic Oversight
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8305166
28 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8302778
21 February 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8104693
8 January 2025
MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8060308
2 January 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7844180
11 December 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7837491
7 December 2023
MSP Annual Oversight · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7826238
12 October 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7808076
11 September 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7789376
1 September 2023
MSP Select Additional Oversight – Risk Assessment
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7782423
28 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7778676
17 May 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7691643
15 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7689231
27 March 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7657516
13 March 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7649926
7 March 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7646631
23 January 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7626397
9 December 2022
MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Activities Europe · Activity 7606670
28 September 2022
MSP Select Drydock Oversight · In-Service Inspection
Physical examination · Activities Europe · Activity 7567690
15 August 2022
MSP Select Additional Oversight – Risk Assessment · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7534158
13 August 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7532294
3 August 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7605607
22 May 2022
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7456405
16 May 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7451716
14 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7451710
11 February 2022
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7394592
9 February 2022
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7393780
1 November 2021
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7343491
30 August 2021
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7307038
19 April 2021
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7178095
19 April 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7183652
9 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7172087
19 February 2021
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7143147
14 January 2021
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7124370
13 January 2021
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7131001
11 January 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7132310
28 December 2020
MSP Annual Oversight · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7117045
16 September 2020
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7058587
15 September 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7058396
10 September 2020
COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7057831
10 September 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7060702
9 September 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7054509
9 September 2020
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7054691
8 September 2020
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7053928
15 August 2020
Deficiency Check · Damage Survey
Physical examination · Activities Europe · Activity 7033502
14 August 2020
Type not recorded
No type recorded · Activities Europe · Activity 7041387
3 March 2020
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6919807
10 December 2019
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6871710
31 January 2019
MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · MSP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6618064
7 June 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6444959
20 November 2017
MSP COI Oversight · COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 6309829
31 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6115425
7 February 2017
Administrative Inspection
Administrative · Activities Europe · Activity 6083921
3 February 2017
Type not recorded
No type recorded · Activities Europe · Activity 6084487
11 January 2016
In-Service Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5796579
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 February 2026
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Cargo hold deck 7 fire damper is seized and unable to be closed. Vessel to repair to the satisfaction of a marine inspector.
74 SOLAS (09) II-2/14.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2026
Resolved 5 February 2026
Resolution: Captain sent video of damper being exercised and was to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 February 2026
No resolution recorded
At intervals of not more than six months, the lifeboat shall either be launched by free-fall or simulated launching. Vessel has a leaking hydraulic cylinder that is being replaced at the dock. Lifeboat was last launched July of 2025. Complete repair and conduct operational test of lifeboat system to satisfaction of marine inspector.
74 SOLAS (24) III/19.3.4.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 February 2026
No resolution recorded
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration IAW regulation XI/1. Found numerous soft patches on non-vital piping. Cargo hold 12, 03 temp repairs on sewage line. Port side near rescue boat,
found temp repair to LT line.
74 SOLAS (04) II-1/3-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 5 February 2026
No resolution recorded
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration IAW regulation XI/1. Found excessive hydraulic fluid leaking from stbd stern ramp control station, as well as weathertight doors needing adjustment to close and seal properly at stbd side cargo hold door leading into stair tower and QAWTD aft cargo hold #8.
74 SOLAS (04) II-1/3-1
Action required: 50 - Rectify deficiencies w/in 30 days
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2026
No resolution recorded
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Found numerous ground wires missing or broken on stbd side lighting fixtures and on purifier room exhaust fan junction box.
74 SOLAS (04) II-1/40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2026 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 December 2023
Resolved
The means for securing doors weathertight shall consist
of gaskets and clamping devices, arranged to be operated from both sides. The weather deck door for the hospital space is missing a lower internal clamping device.
66 ICLL 98 Protocol
Annex I Ch II Reg 12
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2024
Resolved 11 December 2023
Resolution: Report Number: 2224644, v2
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 December 2023
Resolved
A main electric lighting system shall provide illumination throughout parts of the ship normally accessible to and used by crew shall be supplied from the main source of power. Vessel class A machinery space had several fractured/damaged light fixture covers.
74 SOLAS Cons 2020
CH II-1 Reg 41.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 11 December 2023
Resolution: Report Number: 2224644, v2
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 December 2023
Resolved
The launching mechanism shall be so arranged that it may be actuated by one person from a position within the rescue boat. The davit gravity brake release cable parted during lowering of the rescue boat.
74 SOLAS Cons 2020
CH III Reg 16.1
LSA Reg 6.1.2.2
Action required: 10 - Deficiency Rectified
Due 7 December 2023
Resolved 7 December 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 December 2023
Resolved
Doors required to be self closing shall not be fitted with hold back hooks. The Self closing class A door between the galley and common mess room is held back with an installed hook.
74 SOLAS Cons 2020
Ch II-2 Reg 9.4.2.2
Action required: 10 - Deficiency Rectified
Due 7 December 2023
Resolved 7 December 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 December 2023
Resolved
A means shall be provided for automatically giving audible and visual warning of the release of fire extinguishing medium into any ro-ro spaces. Label placard missing from cargo deck eleven indicating discharge of CO2.
74 SOLAS Cons 2020
Ch II-2 10.4.1.1.1
FSS Ch 5.2.1.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 11 December 2023
Resolution: Report Number: 2224644, v2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 14 December 2022
Resolved
The Company should ensure that each ship is:
manned with qualified, certificated and medically fit seafarers in accordance with national and international requirements. One mariner’s TWIC expired in October. Document ID: 06-01-900 indicates the crewing agent is responsible to ensure documents will not expire during shipboard assignment. Any exceptions are to be noted in the Marine Personnel System. Reviewed Marine Personnel System for the mariner and it indicated the TWIC expired in Mar2013. No exceptions were noted in the system.
One mariner had a medical waiver, which is required to be kept on board with MMD. Reviewed Document ID 06-01-914 and there is no pre-screening requirement to notify the company if the mariner has a medical waiver (including corrective lenses) prior to assignment on board a vessel.
Cite: SOLAS (2014) IX/Reg 3.1 ISM Code 6.2
Action required: 705 - Other - as specified
Due 14 March 2023
Resolved 17 March 2023
Resolution: Received updated SMS from MLL.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2022
Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provision of this part in respect of electrical installations. The control system should be designed to include an uninterruptible power supply (UPS) that has sufficient capacity to maintain power to the control system for a period sufficient to bring the emergency power generator online, or if necessary, to safely shut down the equipment. Ground faults were observed in the CAMS DC24V UPS in the Engine Control Room.
Cite: SOLAS (2004) II-1/Reg 40.2 IEEC 45-(2002) 9.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 22 December 2022
Resolution: Deficiency was accepted by RO and issued ID SF-P-007.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 14 December 2022
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. Steam line on cascade tank was found with significant leak.
Cite: SOLAS (2004) II-1/Reg 33.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 22 December 2022
Resolution: Deficiency was accepted by RO and issued ID SF-P-008.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 December 2022
Resolved
The training manual shall contain instructions and information in easily understood terms illustrated whenever possible on the life-saving appliances provided in the ship and on the best methods of survival. The vessel has two types of lifejackets on board and only one type was posted throughout the vessel and noted in the SOLAS Training Manual.
Cite: SOLAS (2009) III/ Reg 35.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 22 December 2022
Resolution: Deficiency was accepted by RO and issued ID SF-P-009.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2022
Resolved
Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable.
• Identified battery charger cable for GMDSS radios with a splice and bundled loose cables.
• In steering, Junction box MJB-SE was missing cable gland.
Cite: SOLAS (2004) II-1/Reg 45.5.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 22 December 2022
Resolution: Deficiency was accepted by RO and issued ID SF-P-010.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2022
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage main winch pump cable was support with plastic zip ties.
Cite: SOLAS II-1(2004)/Reg 45.5.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 22 December 2022
Resolution: Deficiency was accepted by RO and issued ID SF-P-011.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 December 2022
Resolved
A main electric lighting system which shall provide illuminations throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of electrical power. An e-light adjacent from the port side rescue boat was inoperable.
Cite: SOLAS (2004) II-1/Reg 41.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 22 December 2022
Resolution: Deficiency was accepted by RO and issued ID SF-P-012.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 14 December 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The freefall lifeboat would not start due to battery charger cable not properly installed.
Cite: SOLAS (2014) III/Reg 20.2
Action required: 10 - Deficiency Rectified
Resolved 14 December 2022
Resolution: The crew properly connected the charging cable and charged the lifeboat's battery and was able to start boat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 14 December 2022
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The crew was utilizing an obsolete lockout tagout procedure from 2017 (the current SMS procedure is May 2022). The long term tags were not captured in the logbook.
Cite: SOLAS (2014) IX/Reg 3.1 ISM Code 7
Action required: 10 - Deficiency Rectified
Resolved 14 December 2022
Resolution: The crew conducted an audit of the current LOTO procedure and ensured all long term tags and current tags were captured iaw the SMS LOTO procedure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Identified diesel tote On Deck 5 stbd side aft, near gangway/ramp, with active leak.
Cite: SOLAS (2014) Reg 1/11(a)
Action required: 10 - Deficiency Rectified
Resolved 14 December 2022
Resolution: The crew drained the leaking tote into a barrel and are working to eliminate use of totes.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 August 2022
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel's Bridge-to-Bridge certificate expired July 16, 2022. Vessel is scheduled to have technician on board at next port in Jacksonville, Florida.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2022
Resolved 2 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 August 2022
Resolved
All electrical cables and wiring external to equipment shall be at least a flame-retardant type and shall be so installed as not to impair their original flame-retarding properties. Vessel is missing structural fire protection in 220v junction box. Penetration seals shows signs of melting. Vessel to repair at drydock in September.
Action required: 705 - Other - as specified
Resolved 11 December 2022
Resolution: From LR drydock survey dated 29Nov2022: Electric insulation of the main switchboard and all electric equipment were measured and all grounds on the main bus and 220V distrubution system rectified and found satisfactory. Report number: 2172014/SREC2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 August 2022
Resolved
The machinery and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce to a minimum any danger to persons on board. Vessel's M/E air receiver safety valve was incorrectly installed.
Action required: 10 - Deficiency Rectified
Resolved 17 August 2022
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 August 2022
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Vessel had attached a hose to the shaft seal oil head tank. At the accumulator tank the sight glass packing was leaking and air was leaking from the packing.
Action required: 10 - Deficiency Rectified
Resolved 17 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2022
Resolved
Except as provided in paragraphs 5 and 6, life-saving appliances and arrangements required by this chapter shall be approved by the Administration. Various life buoys and areas on rescue boat has unapproved retro reflective tape. Vessel to replace at drydock.
Action required: 705 - Other - as specified
Resolved 11 December 2022
Resolution: From LR drydock survey dated 29Nov2022: All identified life buoys and areas on rescue boat retro reflective tape now replaced by approved tapes and found satisfactory. Report number: 2172014/SREC2
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 August 2022
Resolved
In every ship means shall be provided to prevent overpressure in any part of compressed air systems. Suitable pressure relief arrangements shall be provided for all systems. Vessel had installed a gag on the ship service air receiver.
Action required: 10 - Deficiency Rectified
Resolved 17 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 February 2022
Resolved
Deficiency Code:11104
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. Identified 02 soft patches on fwd port side hull.
Cite:74 SOLAS (2020 CONS) I/REG.II(a)
Action:50
Action Code: a,c
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2022
Resolved
Deficiency Code: 13199
Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter or heater from coming into contact with heated surfaces. Lagging on the fuel transfer pump soaked with fuel.
Cite:74 SOLAS (2009 CONS) II-2 / 4.2.2.6.2
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2022
Resolved
Deficiency Code:09209
Nonconducting mats or gratings shall be provided at the front and rear of the switchboard. Local group starter panels missing matting.
Cite: 74 SOLAS (2004 CONS) II-1/45.2
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2022
Resolved
Deficiency Code:09209
Equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. Identified a ground on the 220V panel.
Cite:74 SOLAS (2204 CONS) II-1/45.1.1
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2022
Resolved
Deficiency Code:13199
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea. E-Gen return house (fuel) leaking.
Cite:74 SOLAS (2020 CONS) I/REG.II(a)
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2022
Resolved
Deficiency Code:13199
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Control air compressor inoperable.
Cite:74 SOLAS (2020 CONS) I/REG.II(a)
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2022
Resolved
Deficiency Code:99101
Safe operation and servicing of the device so that any discharge meets the applicable requirements of 159.53. Several areas identified on the MSD corroded and leaking.
Cite:33 CFR 159.57(a)(2)
Action:50
Action Code: a,c
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 11 February 2022
Resolved
Deficiency Code:09229
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Cable glands have fallen out of the aft winch control panel.
Cite:74 SOLAS (2020 CONS) I/REG.II(a)
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 12 March 2022
Resolution: Resolved to the attending RO.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2022
Resolved
Deficiency Code:99101
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Number 1 + 2 lube oil m/e purifier screens are blacked out.
Cite:74 SOLAS (2020 CONS) I/REG.II(a)
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 16 May 2022
Resolution: RO report uploaded into vessel documents tab, SAT.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 11 February 2022
Resolved
Deficiency Code:15102
The SMS shall be maintained IAW the provisions of the international safety management code. The Company should establish procedures to ensure the ship is maintained and appropriate corrective action is taken. Vessel requested 40+ purchase requests for engine room maintenance items on September 8. 2021. Vessel currently has 28 overdue maintenance items. Due to waiting for ordered parts for some maintenance items. Conduct Internal Audit within 30 days.
Cite:74 SOLAS (2020 CONS) IX/REG.5 / ISM Code 10.2.3
Action:50
Action Code: a,c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2022
Resolved 3 March 2022
Resolution: Resolved to the attending RO.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 November 2021
Resolved
The fixed fire detection system shall be so designed as to detect rapidly the onset of fire in any part of those spaces. The fire detection system, Loop 11/Deck 5, is in fault.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 3 January 2022
Resolution: Lloyd's Register has made this a condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. While getting underway from the pier, the main engine suffered an over speed trip while in astern propulsion. Inform Class (Lloyds Register), troubleshoot causative factors, and provide a repair or resolve report to [name withheld].
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 January 2021
Resolved
SHIPS SHALL BE MAINTAINED IN COMPLIANCE W/MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY RECOGNIZED BY THE ADMINISTRATION; VESSEL'S #3 SSDG UNEXPECTADLY SECURED DUE TO A CRANKCASE OIL MIST ALARM.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 19 February 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 11 January 2021
Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Objective Evidence: Shipboard maintenance system (Ship Manager) has numerous outstanding items to include 140+ engine room maintenance items overdue, bow thruster inoperable for six months, four thousand hours beyond recommended servicing of main engine suction valves, main engine #4 and #6 cylinder liner scuffing beyond manufacturer specification, deck 5 loop 11 fire detection system inoperable and not reported to class, multiple fire dampers for both cargo and house ventilation (deck workshop, CO2 room, #4 engine room) in need of maintenance (repair or replacement), vessel submitted a life raft servicing extension request to life raft manufacturer but failed to request an extension from flag state authority. An additional external verification is required to determine the perpetuated lack of maintenance, the results of which to be submitted to the USCG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 9 April 2021
Resolution: Vessel provided CAP and ABS acceptance of said plan as a result of the audit conducted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 January 2021
Resolved
At all times when the ship is in service, the fire protection systems and firefighting systems and appliances shall be maintained ready for use. Deck 05 fire loop 11 is disarmed due to trouble fault. Demonstrate proper function of Deck 05 fire detection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 19 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 January 2021
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43, as appropriate. Free-fall lifeboat muster station lighting not connected to emergency power. Demonstrate proper operation of emergency lighting at muster station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 19 February 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 January 2021
Resolved
At all times when the ship is in service, the fire protection systems and firefighting systems and appliances shall be maintained ready for use. Limit switch to initiate time delay for purifier room pilot valve is inoperable. Prove proper operation of limit switch.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 19 February 2021
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 11 January 2021
Resolved
Ships, other than passenger ships, of 3,000 gross tonnage and upwards constructed on or after 1 July 2002 when engaged on international voyages, subject to the provisions of regulation 1.4, shall be fitted with a voyage data recorder (VDR). VDR has two error codes. Prove proper function of VDR.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2021
Resolved 19 February 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 December 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Free-fall lifeboat engine took 1 hour to start due to faulty #2 battery. Demonstrate proper starting of free-fall lifeboat engine. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 February 2021
Resolved 19 February 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2020
Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Vessel was unable to maintain dead slow propulsion due to fuel viscosity.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2020
Resolved 16 September 2020
Resolution: Vessel utilized MGO with higher viscosity. See Class report for further details.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 September 2020
Resolved
An alarm sytem shall be provided indicating any fault requiring attention and shall: (51.1.3) activate an audible and visual alarm on the navigation bridge for any situation which requires action by or attention of the officer on watch. The audible alarm for the "sudden stop" on the navigational bridge EOT was inoperable. The light was functioning properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2020
Resolution: Verified proper operation of alarm system via Technician's report and Class Report. See Documents for further details.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 December 2019
Resolved
99101:All vessels greater than 300 gross tons on a voyage of more than 96 hours is required to submit a Notice of Arrival before departure but at least 96 hours before arriving at the port or place of destination.The vessel departed Beaumont, Texas on December 5, 2019 then submitted a Notice of Arrival on December 7, 2019 at 18:29 EST, with an arrival time to Baltimore, MD on December 10, 2019 at approximately 12:00.
33 CFR 160.212(a)(4)
Action required: 10 - Deficiency Rectified
Due 10 December 2019
Resolved 10 December 2019
Resolution: Issued Warning as documented in attached Enforcement Activity.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 4 February 2019
Resolved
Steering gear compartment to ensure working access to machinery and controls, to include gratings or other non-slip surfaces to ensure suitable conditions in the event of hydraulic fluid leak (74 SOLAS (14 cons.) II-1/29.13.2).
Found excessive hydraulic oil on deck in the steering gear room, creating an unsafe condition for local control for emergency steering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 6 February 2019
Resolution: Received class report stating all surfaces have been cleaned.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 February 2019
Resolved
No change shall be made in the structure, material, or scantlings covered by the survey.
Crack found at the elevator door structure, at the engine room deck. Various cracks found in accomadation space doorways, both port/stbd sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 6 February 2019
Resolution: Received class report stating condition of class has been issued.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 February 2019
Resolved
Cargo ships shall carry a rescue boat complying with section 5.1 of the Code.
Grab lines were found to be deteriorated from sun exposure. Navigation light was missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 6 February 2019
Resolution: Received class report stating condition of class has been issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2019
Resolved
Electrical equipment which may constitute a source of ignition shall not be in these compartments.
Batteries were found in the EDG space which were not stored properly and had exceeded their service life.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 6 February 2019
Resolution: Received class report stating all old batteries have been removed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 February 2019
Resolved
Electrical equipment/wiring shall be approved for explosive petrol and air mixtures.
The wiring for multiple cargo space ventilation position switches was exposed and not properly routed through stuffing tubes/J-boxes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 6 February 2019
Resolution: Received class report stating condition of class has been issued.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 4 February 2019
Resolved
Main switchboard shall be arranged to give easy access.
Excess equipment was stored behind the main switchboard, impeding access.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2019
Resolved 6 February 2019
Resolution: Received class report stating area has been cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 4 February 2019
Resolved
Certificate shall be issued after renewal survey which complies with chapters II-1.
the Cargo Ship Safety Construction Certificate had the wrong keel laid date on it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 6 February 2019
Resolution: Received class report stating certificate has been reissued.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 4 February 2019
Resolved
Such certificate shall be issued by the Administration or by any persons authorized by it. The Administration assumes full responsibility for the certificate.
The IOPP had the wrong keel laid date on it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 March 2019
Resolved 13 February 2019
Resolution: Class re-issued IOPP certificate with corrected keel laid date.