MAURY USCG vessel records Sign in
← All vessels

BRAVERY ACE

BRAVERY ACE is a 2000 freight ship. The Coast Guard has recorded 37 inspections since 2000, most recently in June 2026, along with 9 deficiencies and 2 operational controls.

Records from 2000 to 2026. Most recent: inspection, 24 June 2026.

Built
2000
Last inspected
24 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9207120 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-933

Inspections, by type

…with no type recorded5
Years with a record 19 calendar years (2000–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it15683 - Convention (Subpart B), Net Ton
52276 - Convention (Subpart B), Gross Ton
17686 - Dead Weight, Metric Ton
31276 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 37

24 June 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8412810
22 December 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8286103
20 December 2025 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8284764
16 December 2025 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8284085
16 June 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8157059
21 September 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8006649
8 August 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7976792
26 June 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7942791
25 June 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8006645
21 June 2024 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7934213
12 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7848819
28 December 2023 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7842992
17 November 2023 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7826463
10 October 2023 PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7805828
9 November 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7591891
20 October 2022 PSC B · ISPS Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7578233
23 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7484919
12 April 2022 Deficiency Check · Ballast Water Examination · PSC B · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7429281
23 March 2022 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7413463
16 September 2021 PSC A · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7311162
17 June 2021 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7225727
18 November 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7091648
13 August 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6775877
6 February 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6619689
22 December 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6061554
8 October 2015 Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5735994
4 June 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4867067
22 June 2012 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4351947
5 July 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3521571
5 January 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2851191
9 September 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2770963
5 August 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1867538
27 March 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1761073
28 June 2002 Ballast Water Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1638076
31 January 2002 Security Inspection · Re-Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1483186
22 May 2001 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 290136
4 February 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 274202

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 20 December 2025 Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical and electrical requirements of a class society which is recognized by the Administration. PSCO's noted severe deterioration in the thermal insulation on the deck in the low pressure CO2 room. Directly under the low pressure CO2 room in the No.1 Deck Hold No.2, PSCO's observed unapproved repairs consisting of a soft patch of nonmetallic material in the overhead and multiple corroded areas. 74SOLAS(04) Ch.II-I Reg.3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 December 2025
Resolution: Received class report attesting to repairs for defeciency recieved on 20DEC2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 December 2025 Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted to be weathertight when closed. PSCO observed 02 weathertight doros with light able to shine through the seal. ICLL 66 12.1
Action required: 10 - Deficiency Rectified
Due 16 December 2025
Resolved 16 December 2025
Resolution: PSCO witnessed crew provide and use pipe to close door more and fixed gasket on doors.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 December 2025 Resolved
Except otherwise stated, the normal equipment of every lifeboat shall consist of watertight receptacles containing a total of 3L of fresh water. Each container shall be clearly marked with date of packing and expiry, the production lot number, quantity, and instructions for consumption. PSCO observed the drinking water in the lifeboat as plastic jerry cans. 74SOLAS(24) III/31.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2025
Resolved 17 December 2025
Resolution: Received class report attesting to proper water onboard lifeboat.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 10 October 2023 Resolved
Equipment and arrangements for pilot transfer which are installed on or after 01 July 2012 shall comply with the requirements of this resolution and due regard shall be paid to the standards adopted by the Resolution A.1045(27). PSCO unable to verify that Pilot Ladder was properly tested IAW A. 1045(27). 74 SOLAS (20) V/23.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 October 2023
Resolved 12 October 2023
Resolution: Strength Test of both pilot ladders were carried out by crew in presence of Class NK Surveyor w/manufacturer instruction (weight: 529 lbs) w/satisfactory result. Master confirmed w/owner that new pilot ladder will be supplied at next convenience port.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 October 2023 Resolved
Ships shall be designed, constructed & maintained in compliance with the structural, mechanical & electrical requirements of a classification society which is recognized by the Administration. PSCO observed multiple active alarms on Cargo Dk fan Control Panel & Ballast Control Panels. 74SOLAS(2001)II-I/3.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2023
Resolution: The Master of the vessel provided documentation (saved under DEF History DOC) from Class attesting that 15 car deck ventilator fans were overhauled and now found in good working.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 March 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs were notified of a condition of class for the Starboard lifeboat davit winch that has a temporary repaired brake housing, which does not allow for proper launching operation, thus restricting the ability to function as designed. Vessel must meet proper repair deadlines by 18 April 2022 as per the condition of Class. SOLAS I/11 (a)
Action required: 705 - Other - as specified
Due 18 April 2022
Resolved 23 June 2022
Resolution: SE Occasional Survey has been carried out. Lifeboat technician attended onboard and replaced temporary repaired brake housing of Lifeboat Davit Winch (Starboard) by new spare part at this port and carried out performance test with satisfactory result.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 March 2022 Resolved
Recovery time of the rescue boat shall be not more than 5 mins in a moderate sea condition when loaded with its full complement of persons and equipment. If the rescue boat is also a lifeboat, this recovery time shall be possible when loaded with its lifeboat equipment and the approved rescue boat complement of at least six persons. PSCOs were notified of a condition of class for the starboard side lifeboat which is also a rescue boat, lifeboat has a temporary repaired brake housing davit winch, which does not allow for a full complement of crew during launching operations. 74SOLAS(20)III/17.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2022
Resolution: Provided condition of class and required documentation.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 16 September 2021 Resolved
Each ballast water management system (BWMS) manufactured under Coast Guard approval must have a nameplate securely fastened to the BWMS and plainly marked by the manufacturer with a Coast Guard approval number assigned to the BWMS in the certificate of approval. Vessel's BWMS nameplate did not display the Coast Guard approval number or the Maximum Allowable Working Pressure. 33 CFR 151.1510, 46 CFR 162.060-22(b).
Action required: 15 - Rectify deficiencies by next port
Resolved 17 September 2021
Resolution: Received documentation rectifying def from vessel.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 13 August 2019 Resolved
The master, owner, or person in charge of the vessel did not rinse anchors and anchor chains when anchor was retrieved in Japan to remove organisms and sediments.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2019
Resolved 17 August 2019
Resolution: Photo documentation was provided by the vessel showing the anchor has mud on it, then after when it was rinsed and free of all mud which occured 50 nm offshore.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.