← All vessels
LADY CHRISTINA
LADY CHRISTINA is a 2007 tank ship. The Coast Guard has recorded 33 inspections since 2007, most recently in July 2026, along with 37 deficiencies and 2 operational controls.
Records from 2007 to 2026. Most recent: inspection, 21 July 2026.
- Built
- 2007
- Last inspected
- 21 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 37 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9372858 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8MO9
933058
Flag
LIBERIA
—
Maury page id
psix-933058
Inspections, by type
…with no type recorded5
Years with a record
10 calendar years (2007–2026)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton
73626 - Dead Weight, Metric Ton
89187 - Displacement, Metric Ton
22382 - Convention (Subpart B), Net Ton
73626 - Dead Weight, Metric Ton
89187 - Displacement, Metric Ton
22382 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
21 July 2026
COC-TVE Renew · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8438747
12 July 2026
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8436208
21 May 2025
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8140628
28 December 2024
COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8051483
25 November 2024
COE-Administrative
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8039841
1 October 2024
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8012524
4 September 2024
PSC B · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7985233
2 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7905570
29 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7857286
11 October 2023
Deficiency Check · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806470
30 August 2023
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7781016
26 October 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7582971
17 August 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7536671
17 August 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7547305
16 August 2022
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7535092
5 August 2022
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7525338
18 July 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7510267
17 June 2022
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7480076
15 June 2022
COC-TVE Annual · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7476635
13 June 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7476115
29 May 2021
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7208508
30 August 2020
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7046372
30 August 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7048259
30 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7020049
5 June 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6968865
6 February 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6904041
31 January 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6900718
25 December 2019
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6878146
10 January 2008
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3127839
3 January 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3124344
13 December 2007
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3114931
11 December 2007
Random ISPS/MTSA-No PSC · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3113778
7 December 2007
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3110648
Deficiency record · 37
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 July 2026
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended...PSCO observed seawater spraying into the engine compartment from the #2 cargo V.A.C. Pump from a faulty seal.
74 SOLAS (2004 Consolidated) II-1/26.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 21 July 2026
Resolved
The venting systems shall be provided with devices to prevent the passage of flame into the cargo tanks... PSCO observed 04 deteriorated flame screens
74 SOLAS (2004 Consolidated) II-2/4.5.3.3
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 21 July 2026
Resolved
One or more pressure/vacuum - breaking devices shall be provided to prevent the cargo tanks from being subject to: a positive pressure and a negative pressure... PSCO was unable to observe water level of PV breaker to determine if overall tank pressure was in a positive or negative pressure status.
74 SOLAS (2004 Consolidated) II-2/11.6.3.4
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 21 July 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board... PSCO Observed a standpipe and/or prior ullage/sounding opening that was wasted and presented a threat to vent flammable vapors into the atmosphere in a hazardous location. Ensure wasted standpipe is no longer a threat to vent flammable vapors.
74 SOLAS (2024) I/11(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 July 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board... Hydraulic oil was observed on the four port deck, piping, and crane structure.
74 SOLAS (2024) I/11(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 September 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed water leak in vicinity of #2 scrubber pump.
74SOLAS(20) I/11.a
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 October 2023
Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame … PSCO discovered an absent locking mechanism on an A-0 door connecting the engine room and ECR.
74 SOLAS(04)II-2/9.4.1.1.2
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 October 2023
Resolved
Oil fuel pipes … shall be fitted with a cod or valve capable of being closed from a safe position outside the space concerned in the event of a fire … PSCO discovered the quick closing valve for the number three generator was disconnected. Thus not operational.
74 SOLAS(04)II-2/4.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 11 October 2023
Resolved
Materials used in inert gas systems shall be suitable for their intended purpose. … PSCO observed cooling water leak for the boiler exhaust from the intake flange. PSCO witnessed and tested IG fully operational.
74 SOLAS
(20) II-2/5.5.1.1
FSS CODE: 2.2.1.3
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2023
Resolved
Ships shall be provided with arrangements, equipment and fittings of sufficient safe working load to enable the safe conduct of all towing and mooring operations associated with the normal operation of the ship. PSCO discovered two hydraulic pipes connecting the Port Quarter Windless machine for mooring operations, both of which have been fitted with temporary clamps following a rupture incident during mooring operations that occurred on 11OCT23.
74 SOLAS (20)II-1/3-8.2
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 30 August 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 August 2023
Resolved
THE ELECTRICAL POWER AVAILABLE SHALL BE SUFFICIENT TO SUPPLY ALL THOSE SERVICES THAT ARE ESSENTIAL FOR SAFETY IN AN EMERGENCY, AND FOR A PERIOD OF 18 HOURS, EMERGENCY LIGHTING IN ALL CARGO PUMP ROOMS OF TANKERS CONTRUCTED ON OR AFTER 1 JULY 2002. PSCO OBSERVED FUEL IN EMERGENCY GENERATOR ROOM INSUFFICENT FOR 18 HOURS OF OPERATION.V 74 SOLAS (04) II-1/43.2.2.7
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 August 2023
Resolved
A MEANS SO THAT PERSONS ON BOARD CAN SAFELY AND SWIFTLY ESCAPE TO THE LIFEBOAT AND LIFERAFT EMBARKATION DECK. FOR THIS PURPOSE THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: ESCAPE ROUTES SHALL BE MAINTAINED IN A SAFE CONDITION, CLEAR OF OBSTACLES. 74 SOLAS (20) II-2/13.1.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 August 2023
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO LIMIT THE ACCUMULATION OF FLAMMABLE VAPORS. PSCO OBSERVED A MARINE CHEMIST CERTIFICATE WHICH STATED THERE WAS AN ACCUMULATION OF CARGO RESIDUE IN THE BOTTOM OF THE CARGO PUMP ROOM. 74 SOLAS (20) II-2/4.1.2
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 30 August 2023
Resolved
A SHIP WHEN IN A PORT OF ANOTHER CONTRACTING GOVERNMENT IS SUBJECT TO CONTROL BY OFFICERS DULY AUTHORIZED BY SUCH GOVERNMENT CONCERNING OPERATIONAL REQUIREMENTS IN RESPECT OF THE SAFETY OF SHIPS, WHEN THERE ARE CLEAR GROUNDS FOR BELIEVING THAT THE MASTER OR CREW ARE NOT FAMILIAR WITH ESSENTIAL SHIPBOARD PROCEDURES RELATING TO THE SAFETY OF SHIPS. [name withheld] AUDIT WITHIN 90 DAYS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 30 August 2023
Resolved
A TANK OVERFLOW ALARM MUST BE AUDIBLE AND VISIBLE IN THAT PART OF THE DECK WHERE THE CONTAINMENT SYSTEMS ARE LOCATED AND AT THE POINT WHERE CARGO LOADING IS CONTROLLED ON THE TANKSHIP. PSCO OBSERVED THE OVERFLOW INDICATING LIGHT INOPERABLE. 46CFR154.409(e)
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 26 October 2022
Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. PSCO's observed oily water seperator calibration certificate expired.
Marpol 73/78 Annex I/14.7
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 October 2022
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted. PSCO's observed hole in A-60 Door Boundary, making it not meets requirements for the A60 boundary in which is fitted.
74 Solas (2004) II-2 9.4.2.1
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 26 October 2022
Resolved
Hydraulic power operated steering gear shall be provided with a low level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given in the machinery space. PSCO's observed no audible alarm during testing.
74 Solas (2004) II-1 29.12.2
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 5 August 2022
Resolved
All ships of 500 gross tonnage and upwards shall have rudder, propeller, thrust, pitch, and operational mode indicators, or other means to determine and display rudder angle to be readable from the conning position.
PSCO observed a disparity between vessel's rudder angle indicators and actual rudder angle of approximately 35 degrees to starboard following a steering gear failure.
01 - Certificates & Documentation › 013 - Documents › AIS test report
Issued 15 June 2022
Resolved
The Automatic Identification System (AIS) shall be subjected to an annual exam. PSCO observed last AIS annual test dated March 2021.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 15 June 2022
Resolved
Every oil tanker of 150 gross tons and above shall be subject to a renewal survey at intervals specified by the Administration, but not to exceed five years. PSCO observed IOPP expired 15JUNE2022.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 June 2022
Resolved
Where a reserve source of energy consists of rechargeable accumulator batteries or battery, the capacity of the batteries shall be checked at intervals not exceeding 12 months. PSCO observed GMDSS reserve battery check exceeded 12 months.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 June 2022
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of fire-fighting systems and appliances. Per MSC.1/CIRC 1432, foam analysis testing should be carried out annually. PSCO observed foam analysis annual test results were not onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 June 2022
Resolved
The condition of the ship and it equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Following a reported marine casualty, marine inspectors found damage to electrical and lifesaving equipment, and other systems. PSCO observed screw penetrating through bottom of port side lifeboat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 30 August 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment.
ODME valve overboard caused slop to discharge at the dock.
Marpol Annex I / 6.4.1 17ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 August 2020
Resolved
The company should establish procedures to ensure that the ship is maintained in meeting these requirements. The company should ensure that 1. inspections are held at appropriate intervals 2. any non conformity is reported, with its possible cause, if known 3. Appropriate corrective action is taken; and 4. records of these activities are maintained.
Crew could not provide inspection schedule for ODME overboard discharge valve.
74SOLAS14 IX/3.1 ISM Code 10.2 50ac
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 25 December 2019
Resolved
The machinery, boilers, and associated piping systems and fittings shall be installed and protected as to reduce to a minimum any danger to persons on board. During the pumproom exam, PSCO discovered 02 holes on casing of cargo pump #3, which had water leaking and previous temporary repairs made. Until repaired to the satisifaction of class, cargo pump #3 shall not be used for cargo operations.
Cite: 74SOLAS(14) II-1/26.1 Action: 40ac
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 7 December 2007
Resolved
74solas(2004cons.)II-2/10.2.2.3.1.2 Emergency fire pump inoperable
Communications › Alarms/Indicators › Ballast Alarm
Issued 7 December 2007
Resolved
74solas(2004 cons.) II-2/4.5.7.2.2 Fixed gas detection system for the vessel's ballast tanks is inoperable.
Fire Fighting › Fire Hoses › Location
Issued 7 December 2007
Resolved
74solas(2004 cons.) II-2/10.2.3.1.1 Two fire station are missing the hose, nozzle and deck. (forward main deck)
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 7 December 2007
Resolved
MArpol73/78 Annex1/6.4.1 Vessels oil discharge monitoring equipment is inoperable. Vessel is unable to prove proper operation.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 7 December 2007
Resolved
46CFR153.409(b) The vessel's cargo tank high level alarm (open deck light) is inoperable.//
Vessel class (ABS) attended and issued condition of class due to part unavailability, vessel agreed not to load cargo in US prior to repairing (vsl will unload only in next US port) - c.c. due 10 Mar 08
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 7 December 2007
Resolved
46CFR153.408(e) The vessel's cargo tank high level alarm (cargo deck light) is inoperable. //
Vessel class (ABS) attended and issued condition of class due to part unavailability, vessel agreed not to load cargo in US prior to repairing (vsl will unload only in next US port) - c.c. due 10 Mar 08
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 7 December 2007
Resolved
46CFR153.296(g) The on deck emergency shutdown stations are not marked with the legend "emergency shutdown." Legend must be visible from work areas in the part of the deck where the carrgo containment systems are located. Prove labelling to CG prior to next US port.
Personnel › Certificates/Documents/Licenses › License, Third Assistant Engineer
Issued 7 December 2007
Resolved
STCW95 Reg I/10 3rd assistant engineer has flag state endorsement for regulation III/3 but should be III/1.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 7 December 2007
Resolved
On 07 December 2007, the T/S Cancale Star was found to have an inoperative emergency fire pump. The vessel did not report this condition on its notice of arrival as required by 33 CFR 160.215.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.