MAURY USCG vessel records Sign in
← All vessels

SKS SEGURA

SKS SEGURA is a 2007 tank ship. The Coast Guard has recorded 11 inspections since 2007, most recently in March 2019, along with 1 deficiency and 1 operational control.

Records from 2007 to 2019. Most recent: inspection, 15 March 2019.

Built
2007
Last inspected
15 March 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9326718 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
933139
Flag
NORWAY
—
Maury page id
psix-933139

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2007–2019)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it81380 - Convention (Subpart B), Gross Ton
51942 - Convention (Subpart B), Net Ton
81380 - Regulatory (Subpart C or D), Gross Ton
158784 - Dead Weight, Ton
51942 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

15 March 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6643356
5 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6532978
13 August 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6499139
26 May 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6153226
24 May 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6154906
17 May 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6148599
30 September 2015 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5733792
8 March 2010 ISPS II Exam · COC-TVE Renew · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3689739
24 December 2008 COC-TVE Annual · Ballast Water Examination · MARPOL Annex II Examination · ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3384557
16 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3345947
15 December 2007 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3115479

Deficiency record · 1

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 13 August 2018 Resolved
2510 - PSCO observed seals missing on the vessels ODME sample line inlet and outlet. No records of these seals being removed or replaced were logged.74SOLAS(2014) IX/3.1 ISM Part A 2.1 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2018
Resolution: Sector HOU-GAL received a DNVGL class report that served to satisfy the outstanding deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.