← All vessels
BBC MAINE
BBC MAINE is a freight ship. The Coast Guard has recorded 28 inspections since 2007, most recently in July 2026, along with 6 deficiencies and 1 operational control.
Records from 2007 to 2026. Most recent: inspection, 31 July 2026.
- Built
- Not recorded
- Last inspected
- 31 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9357200 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2CN8
933246
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-933246
Inspections, by type
…with no type recorded3
Years with a record
13 calendar years (2007–2026)
The 28 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9625 - Convention (Subpart B), Gross Ton
4260 - Convention (Subpart B), Net Ton
17973 - Displacement, Ton
12792 - Dead Weight, Ton
4260 - Convention (Subpart B), Net Ton
17973 - Displacement, Ton
12792 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 28
31 July 2026
PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8449602
3 August 2025
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8200572
27 March 2025
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8100402
26 March 2025
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8098718
16 March 2025
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8094464
8 December 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7836467
21 March 2023
Deficiency Check · PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7651846
16 March 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7652120
13 September 2022
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7557710
10 September 2021
Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7309031
6 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7072179
2 March 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6918834
14 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6683928
9 April 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6655226
1 August 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6495678
11 July 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6475202
14 April 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6390603
9 April 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6388207
2 April 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6383623
5 October 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6012617
20 March 2016
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5836741
17 March 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5835331
2 May 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4298686
17 September 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4145792
31 October 2008
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3354903
12 September 2008
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3323854
27 July 2008
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3281372
13 December 2007
Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3115206
Deficiency record · 6
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 August 2025
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
During operational test of rescue boat, PSCO observed engine was unable to turn either direction.
74 SOLAS (2) III / 20.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 March 2025
Resolved
The fire resistance of doors shall be equilvent to that of the division which they are fitted. PSCO observed three A-15 class boundry doors in the cable trunk with penetrations inpacting the doors fire rating.
74 SOLAS (04) / 9.4.2.1
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2025
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily avaliable for immediate use. PSCO observed fighted CO2 relay disconnected rendering a signficant portion of the CO2 system inoperable.
74 SOLAS (04) / 14.2.1.2.1.2
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 September 2022
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed that the vessel water mist system water supply from the systems pump was in the closed position and the system’s pump was switched to non-automatic. Vessel operates as a periodically unmanned machinery space. Vessel’s crew explained that the system had been turned off while the crew welded in the engine the morning of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 March 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the outboard motor on the rescue boat could not engage gears to go ahead or astern.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 5 October 2016
Resolved
0715 - Detection - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization. PSCO observed that the vesseel did not have proper testing eqpmt for the UV flame detectors. Also, PSCO observed there were no maint/testing records for the detectors. 74 SOLAS (14) II-2/14.2.2.1 16a
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.