ALLURE OF THE SEAS is a 2010 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2016, most recently in May 2026, along with 19 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 2 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it225282 - Regulatory (Subpart C or D), Gross Ton 225282 - Convention (Subpart B), Gross Ton 19750 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 33
2 May 2026PSC B · COC-CVE Quarterly · Administrative Inspection
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2026Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivelant to that of the bulkheads in which the doors are situated. FD TW 2.3 (A-60 fire door) located in the forward sewage room not able to close and latch, compromising the structural fire integrity of the boundary.
74 SOLAS 20 II-2/9.4.1.1.5.2
15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 May 2026
Resolved 2 May 2026
Resolution: Doors adjusted and latched
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2026Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have the resistance to fire equivelant to that of the divisions. The B-15 door located on Deck 03, adjacent to cabin 578, B-15 leading into vitality spa, and B-0 door on deck 14 leading into adventure ocean theatre were unable to close and latch, compromising the structural fire integrity of the boundary.
74 SOLAS 20 II-2/9.4.1.2.1
15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 May 2026
Resolved 2 May 2026
Resolution: Doors adjusted and now latch closed
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2026Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to the fire as well as to the passage of smoke and flame equivelant to that of the bulkheads in which the doors are situated. FD 3.4.16, located in theatre ("A" class division), was not able to properly close and latch, compromising the structural fire integrity of the boundary.
74 SOLAS 20 II-2/9.4.1.1.2
15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 May 2026
Resolved 2 May 2026
Resolution: Door adjusted and corrected
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2026Resolved
Fire doors in main vertical zone bulkhead, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement, FD 3.4.22 (forming MVZ 4) had a closure time of 04 seconds.
74 SOLAS 20 II-2/9.4.1.1.5.2
15ac
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 3 May 2026
Resolved 2 May 2026
Resolution: Door adjusted and corrected
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 May 2026Resolved
Companies, masters and crew members each have responsibiltiies to insure that each crew memeber can make a knowledgeable and informed contribution to the safe operation of the ship. Procedures for the safe operation of the ship include safety, environmental protection, security, and emergency procedures. Three different crew members were unfamiliar with ships procedures regarding passengers in restricted areas.
STCW 2017 A-1/14.1
16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2026
Resolved 11 May 2026
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 8 November 2025Resolved
Companies, masters, and crew members each have responsibility to ensure that each crew member can make a knowledgeable and informed contribution to the safe operation of the ship.
PSCO observed that guest cabins on decks 6, 7, and 9 were propped open by the doors' deadlocks during the abandon ship drill.
STCW 2017 A-I/14.1
Code 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 November 2025
Resolved 1 December 2025
Resolution: Vessel has updated their SOP to ensure housekeeping staff does not leave cabin doors open.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2025Resolved
Paint lockers shall be protected by either a carbon dioxide system, a dry powder system, a water-spraying or sprinkler system. In all cases, the system shall be operable from outside the protected space.
PSCO observed that the installed high fog sprinkler system protecting the paint locker is not able to be operated from outside the space.
74SOLAS(20) II-2/10.6.3.1
Code 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2025
Resolved 1 December 2025
Resolution: Flag issued an exemption certificate stating "paint locker is fitted with a water mist fire extinguishing system with an automatic release frangible bulb and is considered equivalent in meeting with requirements of the Regulation...."
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 November 2025Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement.
PSCO observed main vertical zone fire doors obstructed by trash cans on deck 3 and luggage on deck 2.
74SOLAS(20) II-2/9.4.1.1.5.2
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 November 2025Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place.
PSCO observed that 01 oxygen cylinder in the medical oxygen locker in not secured in a rack.
46 CFR 147.60(b)(1)
Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 November 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 January 2025Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces... PSCO's observed an escape path located outside of the security office's door in way of the escape route that needed a key card to open.
74SOLAS20 II-2/13.3.2.2
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 10 January 2025
Resolved 10 January 2025
Resolution: PSCO observed vessel install a breakable key box allowing exit.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 January 2025Resolved
Oil fuel pipes which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500L and above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside of the space. PSCOs observed the starboard side EDG fuel tank quick closing valve required more than one pull to activate.
74SOLAS20 II-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2025
Resolved 10 January 2025
Resolution: PSCOs observed vessel bleed system of air and witnessed it operate fully with one pull.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 January 2024Resolved
Where "A" class divisions are penetrated, such penetrations shall be tested in accordance with the fire test procedures code. Such penetrations shall be suitably insulated by extension of the insulation at the same level of the division. Multiple locations lacking proper insulation. Deck 2 Stairwell 8-A and Deck 2 Zone 6-B Starboard aft near concierge lounge.
07199
74 SOLAS 20 II-2/9.3.1 - 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2024
Resolved 11 January 2024
Resolution: Vessel installed class approved insulation.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 January 2024Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. Low location lighting found extinguished on Deck 7 and Deck 8 port side Zone 4-B.
74 SOLAS II-2/13.3.2.5.1 - 10ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 January 2024
Resolved 8 January 2024
Resolution: New lighting was installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 July 2023Resolved
Manually operated call points complying wuth the Fire Safety Systens Code shall be installed throughout the accommodation spaces, service spaces and control stations. One manually operated call point shall be loacted at each exit. manually operated call points shall be readily accessible in the corridors of each deck such that no part of the corridor is more than 20 m from a manually operated call point. PSCO observed manual call point D1353 on deck six inoperable when tested. Ships force tested and found call point was damaged and replaced with spare and tested satisfactory and is operating as designed . Action code 10c was noted on form B.
Deficiency Code 07106
74SOLAS 20 II-2/7.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 July 2023
Resolved 9 July 2023
Resolution: Ships force replaced with spare call point and tested satisfactory, Deficiency rectified prior to USCG departing vessel.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 July 2021Resolved
07116- Ventilation - Exhaust ducts from laundries...shall be fitted with filters readily removable for cleaning purposes and suitably located hatches for inspection and cleaning. PSCOs observed missing filters in crew laundry deck 11 and aft mooring deck laundry and latching mechanism was broken on the hatch in crew laundry deck 11. 74 SOLAS 20 II-2/10.7.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2021
Resolved 5 August 2021
Resolution: Vessel submitted class report verifying correction of deficiency
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2021Resolved
07 - Fire Safety - Storage of combustibles is prohibited in auxiliary machinery spaces having little or no fire. PSCOs witnessed storage of combustible materials in AC room 5-1. 74 SOLAS 09 II-2/9.2.2.3.2(10)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 August 2021
Resolution: Vessel submitted class report verifying correction of deficiency
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 October 2017Resolved
0750-Fire Prevention- Doors in "A" class divisions shall provide resistance to fire as well as to passage of smoke and flame equivalent to bulkheads. Fire screen doors numbered 11.7.4, 8.5.5, 8.5.3, and 6.6.2 could not fully close when tested. 74 SOLAS (14 Cons) II-2/ Reg 9.4.1.1.2
Action required: 705 - Other - as specified
Due 29 October 2017
Resolved 29 October 2017
Resolution: Doors were corrected on the spot by adjustment of closure mechanism.
The officer in charge and master both signed the garbage record, dated 30 APr 2107, prior to proper entries being made. MARPOL (11) Annex V/9.3(a) 10c
Action required: 705 - Other - as specified
Resolved 30 April 2017
Resolution: Discussion was held with master and proper entry was made in the garbage record book.
Personnel › Training › Familiarization Training
Issued 30 April 2017Resolved
Crew demonstrated a lack of competency during both fire and abandon ship drills, specifically emergency procedures unknown by numerous stairwell guides. STCW (Conv)
CH VI/6.1.1 10c
Action required: 705 - Other - as specified
Resolved 30 April 2017
Resolution: Training held for crew beyond the scope of the scripted safety booklet questions and first aid techniques.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.