Records from 2016 to 2023. Most recent: inspection, 22 February 2023.
Inspection history · 19
22 February 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7640567
30 November 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7601803
5 September 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7552175
19 December 2021
PSC B · MARPOL Annex VI Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7370314
1 July 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7242698
31 May 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6964610
26 May 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6960651
5 January 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6882950
24 December 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6878538
22 December 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6877900
24 October 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6566045
11 July 2018
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6474076
22 February 2018
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6359278
4 October 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280898
30 September 2017
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6278388
19 September 2017
Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6270220
9 January 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6068181
16 November 2016
PI Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6042333
12 November 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6039656
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 June 2020
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The freefall lifeboat’s steering system and rudder cannot be controlled from the helm and would not move to either port or starboard.
74SOLAS (2014 CONS) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 June 2020
Resolved 1 June 2020
Resolution: Crewmembers repaired rudder to the satisfaction of PSCOs by adding hydraulic fluid, deficiency noted for documentation.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 4 October 2017
Resolved
0610 - Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. The free fall lifeboat's steering system and rudder cannot be controlled from the helm and would not move to either port or starboard. - 74 SOLAS (2014 Cons.) III/20.2
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 4 October 2017
Resolution: Deficiency was rectified prior to completion of inspection.
Engineering › Fuel Oil Service System › Piping
Issued 16 November 2016
Resolved
1420-Means shall be provd. to ctrl leaks of flam liquids. The #1gen is leaking fuel continuously from the fuel pump and piping system, the main diesel engine duplex fuel filter is leaking fuel from the main housing seal and valve, and fuel is leaking from multiple places t/o engine room. Non-flam containers were obsvd t/o the engine room being used to contain fuel oil.74SOLAS(2009CONS)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2016
Resolution: Deficiency was merged with Deficiency #1.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 16 November 2016
Resolved
0610- LSA – Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The freefall lifeboat's steering system and rudder cannot be controlled from the helm and would not move to either port or starboard. 74 SOLAS (2009 CONS) III/20.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2016
Resolution: The freefall lifeboat's steering system was repaired and tested operational.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 November 2016
Resolved
1740-Marine Poll–Any ship 400GT+ shall be fitted with oil filtering equip shall be as such as to ensure that any oil mixture discharged to the sea has an oil content meter not exceeding 15 ppm. Crew attempted to demonstrate OP test of OWS, the oil content meter was activated and the display was completely unreadable, resulting in the inability to ascertain oil content. MARPOL 2011Annex I/14.7
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2016
Resolution: OWS display was repaired and now operational.
Engineering › Fuel Oil Service System › Filter
Issued 16 November 2016
Resolved
1420- Prop & Aux Mach. – The following functional reqs. Shall be met: means shall be provided to control leaks of flammable liquids, the main diesel engine duplex fuel filter is leaking fuel from the main housing seal & valve. 74 SOLAS (2009 CONS) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 November 2016
Resolution: Deficiency was merged with Deficiency #1.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 November 2016
Resolved
1420 - Prop & Aux Mach. – The arrangement for the stowage, distribution & utilization of the fuel shall be such as to ensure the safety of the ship & persons onboard. Multiple machinery oil entrapments full of fuel were found along with several non-flammable containers with fuel/oil throughout the engine room. 74 SOLAS (2009 CONS) II-2/4.2.2
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2016
Resolution: All identified fuel leaks on engine room machinery was satisfactorily repaired.
Construction/Loadline › Structures › Door
Issued 16 November 2016
Resolved
1270- Load Lines – The means of maintaining weathertightness shall ensure that the tightness can be maintained in any condition. Weathertight door "511B" Deck 2 starboard side and frame were severely corroded and wasted. Door cannot fully seal due to wastage making the door not weathertight. ICLL 66 Annex I/16.4
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2016
Resolution: Weathertight door was reconditioned and door frame was replaced.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 16 November 2016
Resolved
1575 – Navigation – All ships of 300 GT and upwards shall be fitted with an echo depth sounding device. The vessel’s echo depth sounder is inoperable. 74 SOLAS (2014 CONS) VI/19.2.3.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2016
Resolution: The vessel’s echo depth sounder was repaired and verified operable.