MAURY USCG vessel records Sign in
← All vessels

KENT

KENT is a 2007 tank ship. The Coast Guard has recorded 20 inspections since 2007, most recently in March 2017, along with 4 deficiencies and 6 operational controls.

Records from 2007 to 2017. Most recent: inspection, 16 March 2017.

Built
2007
Last inspected
16 March 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9343118 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
934163
Flag
LIBERIA
—
Maury page id
psix-934163

Inspections, by type

…with no type recorded7
Years with a record 7 calendar years (2007–2017)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22914 - Convention (Subpart B), Gross Ton
6874 - Convention (Subpart B), Net Ton
37139 - Displacement, Ton
26438 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

16 March 2017 Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6105729
22 September 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6006543
24 July 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5950874
9 March 2016 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5828421
28 October 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5013731
26 August 2014 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4958751
25 August 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4965141
22 December 2010 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3914678
28 November 2010 Ballast Water Examination · Administrative Inspection · COC-GAS Annual · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3899647
5 November 2010 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3888716
29 October 2010 PI Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3880812
15 February 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3680152
18 January 2010 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3691600
18 December 2009 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3651439
15 December 2008 Ballast Water Examination · COC-GAS Annual · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3378089
8 December 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3376501
16 June 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3238667
29 January 2008 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3138491
21 December 2007 ISPS II Exam · COC-GAS Renew
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3119520
16 December 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3116627

Deficiency record · 4

Construction/Loadline › Markings › Load Line Mark
Issued 28 November 2010 Resolved
1220 : ILLC Annex I Reg. 8; The rings, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Vessel load line was rusty and the deck line is painted the same color as the rest of the hull.
Action required: 705 - Other - as specified
Due 6 January 2011
Resolved 22 December 2010
Resolution: Rcvd class report attesting to proper marking of the load line.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 18 December 2009 Resolved
Vessel does not have on board a copy of Inland Navigation Rules.
Action required: 705 - Other - as specified
Due 18 January 2010
Resolved 18 January 2010
Resolution: Vessel had on board a copy of Inland Navigation Rules.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 21 December 2007 Resolved
Aft port manifold valve indicator in control room does not indicate the proper position of the valve. Class surveyor to attest to proper functioning of indicator and provide report to US Coast Guard.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 29 January 2008
Resolution: Received class report attesting to proper repairs
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 21 December 2007 Resolved
MM5000 Gas Detection System is inoperable. Class surveyor to attest to proper functioning of detection system and associated power shut down and send report to U.S. Coast Guard. Samples to be taken and logged every 30 minutes of all holds and detection cabinet while in the port of Savannah including to the Sea Bouy.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 29 January 2008
Resolution: Received class report attesting to proper repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.