MAURY USCG vessel records Sign in
← All vessels

GEMINI PEARL

GEMINI PEARL is a 2007 tank ship. The Coast Guard has recorded 26 inspections since 2007, most recently in September 2025, along with 9 deficiencies and 4 operational controls.

Records from 2007 to 2025. Most recent: inspection, 15 September 2025.

Built
2007
Last inspected
15 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9365362 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
934808
Flag
PANAMA
—
Maury page id
psix-934808

Inspections, by type

…with no type recorded5
Years with a record 14 calendar years (2007–2025)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30042 - Regulatory (Subpart C or D), Gross Ton
13312 - Regulatory (Subpart C or D), Net Ton
30042 - Convention (Subpart B), Gross Ton
10082 - Displacement, Metric Ton
13312 - Convention (Subpart B), Net Ton
50561 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

15 September 2025 COC-CHEM & TVE Renew
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8233555
9 September 2025 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8230015
30 July 2024 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7970287
20 September 2023 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7795066
30 July 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7755739
12 September 2021 PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7309372
4 November 2019 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6845849
23 August 2018 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6520479
1 October 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6278175
8 November 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6037837
29 September 2016 COE-Dockside
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6011406
1 July 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5927469
12 May 2016 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5875682
2 May 2016 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5867194
28 April 2016 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5862000
30 July 2012 ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4387820
18 July 2012 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4383016
1 July 2011 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4059505
28 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3899885
7 September 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3844029
17 December 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3651847
7 December 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3646160
2 April 2009 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3444915
16 February 2009 MARPOL Annex II Examination · Ballast Water Examination · ISPS II Exam · COC-CHEM Annual · MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3417171
13 August 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368406
28 December 2007 MARPOL Annex II Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3121682

Deficiency record · 9

02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 15 September 2025 Resolved
74 SOlAS (20) II-2/11.6.3.2: A secondary means of allowing full flow relief of vapor, air, or inert gas mixtures shall be provided to prevent over pressure or under presure in the event of failure of the arrangments. Alternatively pressure sensors may be fitted in each tank with a monitoring system in the ship's cargo control room of the position from which cargo operations are normally carried out. Such monitoring equipment shall also provide an alarm facility which is activated by detection of over pressure or under pressure conditions within a tank. PSCO observed cargo tank 2(P) pressure sensor malfunction and alarm triggered in CCR.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 16 September 2025
Resolution: Flag dispensation has been granted
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 30 July 2023 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect unless the administration is satisfied that such equipment is appropriate to the space concerned. PSCO found conduit piping for the following to be wasted through allowing vapors to enter protected spaces: temperature sensor conduit for 2 port and 6 stbd; pressure sensor conduit for 1 stbd, 2 port, 2 stbd; junction box conduit for 5 stbd, port slop, stbd slop. Rectify to the satisfaction of class prior to cargo. Cite: 74 SOLAS (04) II-1/45.10 Action: 17ac (changed to 40ac) Effect permanent repairs to indicated piping prior to next U.S. port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 July 2023
Resolved 20 September 2023
Resolution: Received class report attesting to satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 30 July 2023 Resolved
Means shall be provided to control the leaks of flammable liquids. PSCO found fuel injector on #1 generator to be spraying fuel oil. Vessel shall not operate the #1 Generator until repairs are made to the satisfaction of class. Cite: 74 SOLAS (04) II-2/4.1.2 Action: 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2023
Resolved 4 August 2023
Resolution: Vessel sent class report with satisfactory repairs made to control the leak.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 30 July 2023 Resolved
Where the atmosphere in double hull spaces cannot be reliably measured using flexible gas sampling hoses, such spaces shall be fitted with permanent gas sampling lines. PSCO was unable to witness proper operation of the fixed hydrocarbon gas detection system due to a flow fault when cycling sample points. Cite: 74 SOLAS (04) II-2/4.5.7.2.2 Action: 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2023
Resolved 20 September 2023
Resolution: Received class report attesting to satisfactory repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 July 2023 Resolved
Means shall be provided to control the leaks of flammable liquids. PSCO observed lower sight glass of M.E. lube oil tank to be gagged in the open position. Cite: 74 SOLAS (04) II-2/4.1.2 Action: 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 30 July 2023
Resolved 30 July 2023
Resolution: Deficiency corrected on the spot by removing gag.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 31 May 2016 Resolved
For tanks of 20,000 tonnes deadweight and upward, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the fire safety systems code. Vessels main inert gas system inoperable, temporary inert gas unit has been installed onboard. Vessel is allowed to conduct one time cargo discharge once the conditions of the Captain of the Port Orde
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2016
Resolution: Attending PSCOs witnessed satisfactory operation of IGG and full functionality of all alarms/shutdowns in company of attending DNV-GL surveyor.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 31 May 2016 Resolved
At least two blowers shall be fitted and be capable of delivering to the cargo tanks at least the volume of gas required by paragraph 2.2.1.2 and 2.2.1.3 for systems with gas generators, the administration may permit only one blower if that system is capable of delivering the total volume of gas required by paragraphs 2.2.1.2 and 2.2.1.3 to the protected cargo tanks, provided that sufficient spare
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2016
Resolution: Permanent IGG has been permanently repaired and is fully functional at this time; therefore temp IG is not longer required.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System › Foam Source
Issued 30 July 2012 Resolved
Vessel holds a Certificate of Fitness under IBC. IBC states that foam shall not be of the regular protien type. Vessel has regular protien type onboard. Prior to carrying Annex II cargoes, vessel must have proper fire fighting foam onboard. Further, vessel is not in compliance with the Certificate of Fitness. SOLAS 74 (2004 Cons. Ed.) CH. VII/ 10.1 IBC CH. 11.3.2 70 A/C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 August 2012
Resolution: Class report submitted attesting to proper/compatable foam to be used when carrying Annex II cargoes.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 30 July 2012 Resolved
Vessel's IGG had a hole and resultant leak in way of a weld seam on the underside of the burn unit. This resulted in jacket water being discharged onto the deck. SOLAS 74 (2004 Cons. Ed) CH. I/11 70 A/C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 August 2012
Resolution: Class provided documentation attesting to the repair and proper operation of the IGG.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.