CSC PEACE is a 2007 tank ship. The Coast Guard has recorded 8 inspections since 2018, most recently in May 2025, along with 5 deficiencies and 1 operational control.

Records from 2018 to 2025. Most recent: inspection, 9 May 2025.

Built
2007
Last inspected
9 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 May 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9344148
934902
Flag
HONG KONG
Maury page id
psix-934902

Documentation record

Tonnage as PSIX records it29593 - Simplified, Gross Ton
29593 - Convention (Subpart B), Gross Ton
12466 - Simplified, Net Ton
45886 - Dead Weight, Ton
57669 - Displacement, Ton
12466 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

9 May 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8131509
27 April 2025 PSC B · COC-TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8115843
27 April 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8121137
25 April 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8121148
21 April 2025 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8115836
18 October 2023 COC-TVE Renew · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7810322
27 May 2019 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6687184
14 April 2018 Ballast Water Examination · PII Safety Exam · Deficiency Check · COC-TVE Renew · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6391620

Deficiency record · 5

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2023 Resolved
"AFTER ANY SURVEY OF THE SHIP...HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN STRUCTURAL ARRANGEMENTS..., WITHOUT THE SANCTION OF THE ADMINISTRATION." PORT STATE CONTROL FOUND MULTIPLE UNAUTHORIZED TEMPORARY REPAIRS TO BOTH PORT AND STARBOARD SIDE ANCHOR SALTWATER FLUSH LINES. 74SOLAS(20) I/11(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 April 2025
Resolved 21 April 2025
Resolution: Review Class Report, Satisifactory.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 15 April 2018 Resolved
AUTOMATIC SHUTDOWN OF THE INERT GAS SYSTEM AND ITS COMPONENTS PARTS SHALL BE ARRANGED ON PRE-DETERMINED LIMITS BEING REACHED. THE FOLLOWING IG ALARMS WERE NOT SET IAW THE APPROVED IG MANUAL: HIGH TEMP COOLING SEA WATER, LOW PRESSURE SW SCRUBBER, HIGH PRESSURE DECK, SCRUBBER OUTLET LOW PRESSURE, HIGH TEMP INERT GAS, LOW PRESSURE FUEL OIL IGG. 74SOLAS(04)II-2/4.5.5.3.2 AND FSS CH.15.2.2.2.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2018
Resolved 16 April 2018
Resolution: See attached Class Report in Documents
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 15 April 2018 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO THE CONDITION AFTER SURVEY. THE PROTECTIVE METAL SCREENS BETWEEN THE CARGO PUMP POWER PACK AND PRIME MOVERS ARE HOLED OR HAVE VISIBLE GAPS. 74SOLAS(14)CH1/REG11 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2018
Resolved 16 April 2018
Resolution: See attached Class Report in Documents
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 15 April 2018 Resolved
AUDIBLE AND VISUAL ALARMS SHALL BE PROVIDED TO INDICATE GAS PRESSURE LESS THAN 100MM WATER GUAGE. TWO IG PRESSURE SENSORS DRAWING FROM THE SAME LINE READ 40MMWG DIFFERENCE. 74SOLAS(04)II-2/4.5.5.3.2 , FSS 15.2.2.4.5.1.3 , 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2018
Resolved 16 April 2018
Resolution: See attached Class Report in Documents
Electrical › Electric Supply System (service) › Cable
Issued 15 April 2018 Resolved
WHERE CABLES WHICH ARE INSTALLED IN HAZARDOUS AREAS INTRODUCE THE RISK OF FIRE OR EXPLOSION IN THE EVENT OF AN ELECTRICAL FAULT IN SUCH AREAS, SPECIAL PRECAUTIONS AGAINST SUCH RISKS SHALL BE TAKEN TO THE SATISFACTION OF THE ADMINISTRATION. PSCO OBSERVED CHAFFED INSULATION ON ELECTRICAL WIRES IN THE IG PRESSURE SENSOR CONTROL BOX ON CARGO DECK. 74SOLAS(04)II-1/45.5.4 , 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2018
Resolved 16 April 2018
Resolution: See attached Class Report in Documents