RADIANT PRIDE
RADIANT PRIDE is a 2007 tank ship. The Coast Guard has recorded 36 inspections since 2008, most recently in November 2025, along with 36 deficiencies and 6 operational controls.
Records from 2008 to 2025. Most recent: inspection, 17 November 2025.
- Built
- 2007
- Last inspected
- 17 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 36 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9307097 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5RC2
935185
Flag
LIBERIA
—
Maury page id
psix-935185
Inspections, by type
…with no type recorded8
Years with a record
15 calendar years (2008–2025)
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it42010 - Convention (Subpart B), Gross Ton
22382 - Convention (Subpart B), Net Ton
73635 - Dead Weight, Metric Ton
89187 - Displacement, Metric Ton
22382 - Convention (Subpart B), Net Ton
73635 - Dead Weight, Metric Ton
89187 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 36
17 November 2025
COC-TVE Renew · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8269934
29 January 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8069800
2 January 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8056664
30 October 2024
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8027245
30 September 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8012110
28 September 2024
Administrative Inspection · Deficiency Check · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8010840
27 September 2024
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8010286
16 May 2024
COC-TVE Annual · Administrative Inspection · Deficiency Check · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7911380
5 March 2023
COC-TVE Renew · PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7643226
7 September 2022
Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7553530
1 September 2022
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7548945
1 September 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7549520
7 April 2022
PSC B · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426407
6 April 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7436042
29 January 2021
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7132957
15 June 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6977873
28 November 2019
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6859396
7 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6706717
29 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6698322
28 November 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6587955
22 May 2017
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6139950
13 June 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5905693
13 June 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5906574
7 June 2016
ISPS II Exam · Ballast Water Examination · Deficiency Check · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5899590
9 March 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829950
9 March 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5831133
29 October 2015
COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5753284
27 May 2014
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4870283
15 May 2014
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4856367
27 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3687190
12 January 2010
COC-TVE Renew · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex VI Survey · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3660735
30 March 2009
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3443225
26 March 2009
COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3438427
26 February 2009
ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3424320
26 January 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3400746
2 January 2008
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · COC-TVE Renew · PII Safety Exam · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3123473
Deficiency record · 36
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 January 2025
Resolved
74 SOLAS (2020 Cons.) IX/3.1 ISM Code 10.2.3
The company and the ship shall comply with the requirements of the International Safety Management Code. The company should establish prodecures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. In meeting these requirements, the company should ensure that appropriate corrective action is taken. The technical and operational nature of deficiencies 02-05 provide objective evidence of a serious failure of the implementation of the ISM Code. A targeted external audit of the ship's maintenance, the condition, company responsibilities satisfactory to the OCMI must be submitted prior to clearance of the deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 29 January 2025
Resolved
74 SOLAS (2004 Cons.) II/10.1
The purpose of this regulation is to suppress and and swiftly extinguish a fire in the space of origin. For this purpose, fire extinguishing appliances shall be readily available. The emergency fire pump non-return valve on the discharge side was replaced with a manual valve rendering the pump unable to be remorely activated as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 January 2025
Resolved
74 SOLAS (2020 Cons) Ch. III/20.2
All lifesaving appliances shall be in working order and ready for immediate use. Starboard lifeboat throttle cables for forward and reverse were switched.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2025
Resolved
74 SOLAS (2020 Cons.) Ch. I/11(a)
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons. #2 boiler has multiple cracked pipes internally, rendering the boiler inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 29 January 2025
Resolved
74 SOLAS (2020 Cons.) Ch. II-1/33.1
Every steam pipe shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subjected. PSCOs observed a fractured steam pipe coming from steam injectors on the deck above the cargo pumps in the engine room.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 September 2024
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company.
In meeting these requirements the Company should ensure that:
.2 any non-conformity is reported with its possible cause, if known;
.3 appropriate corrective action is taken.
The technical and/or operational nature of deficiencies 02 - 08 provide objective evidence of a serious failure of the implementation of the ISM Code. The crew is reporting conditions to the company, however the below conditions are not being reported to class/flag nor are they being rectified.
An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency.
74 SOLAS (20)IX/3.1
ISM Code 10.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2024
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control.
PSCO observed the main engine is inoperable from the bridge and engine control room. The crew states they have been operating the main engine from the local (emergency) platform since June. This condition has been reported to company without rectification.
74 SOLAS (04)II-1/31.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 September 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: .1 means shall be provided to control leaks of flammable liquids;
PSCO observed oil leaks and accumulated oil: -around the auxiliary blower, all five fuel pumps, all five cylinder heads, crankcase explosion covers 3 - 5, and in the bilge forward of the main engine.
-Around the flywheel for generator 1 and 3. Generator 3 had a fabricated catch collecting oil leaks.
-Around the fuel tank for the emergency generator.
-And near the steering gear pedestal.
74 SOLAS (04)II-2/4.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2024
Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS OR IN COMPARTMENTS ASSIGNED PRINCIPALLY TO ACCUMULATOR BATTERIES IN PAINT LOCKERS, ACETYLENE STORES OR SIMILIAR SPACES, UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS 0F A TYPE WHICH WILL NOT IGNITE THE MIXTURE CONCERNED.
PSCO OBSERVED AN EXPLOSION PROOF LIGHT LOCATED IN THE BATTERY ROOM ON THE NAVIGATION BRIDGE MISSING A GLAND IN ONE OF THE STUFFING TUBES.
PSCO OBSERVED 2 EXPLOSION PROOF LIGHTS LOCATED IN THE CARGO DECK STORE, WHICH IS INDICATED AS A HAZARDOUS LOCATION PER THE VESSELS APPROVED HAZARDOUS LOCATION PLAN, RETRO-FITTED WITH IMPROPER GLANDS.
74 SOLAS (2004) II-1/45.10.2
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 28 September 2024
Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS.
PSCO OBSERVED STEAM CREAKS ON THE STEAM PIPING FORWARD OF COT 6S, FORWARD OF THE COT 3 P/S, ON THE STEAM TURBINES FOR ALL 3 CARGO PUMPS, AND ON THE STEAM RETURN LINE IN THE ENGINE ROOM. ADDITIONALLY, PSCO OBSERVED A FABRICATED CATCH COLLECTING LEAKING JACKET WATER ON GENERATOR 1 AND A FUNNEL DIRECTING JACKET WATER FROM A LEAKING VALVE NEAR THE JACKET WATER COOLING HEAT EXCHANGERS INTO THE BILGE.
74 SOLAS (2004) II-1/26.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed auxiliary boiler #1 inoperable, fixed gas detection for the ballast tanks is inoperable, and fixed gas for the cargo pump room has faults on sampling point #20 due to a bad sensor.
74SOLAS (2020) I/11
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 September 2024
Resolved
THE FIRE RESISTANCE OF DOORS SHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED, THIS BEING DETERMINED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES CODE. DOORS AND DOOR FRAMES IN "A" CLASS DIVISIONS SHALL BE CONSTRUCTED OF STEEL. DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GAS TIGHT AND SELF-CLOSING.
PSCO OBSERVED CLASS A SELF-CLOSING FIRE DOOR FOR THE BRIDGE STORE LOCATED IN THE MAIN LADDER WELL, CARGO CONTROL ROOM, AND PURIFIER ROOM UNABLE TO SELF-CLOSE. ALL DOORS ARE LABELED AS CLASS A SELF-CLOSING DOORS ON THE APPROVED FIRE CONTROL PLAN.
74SOLAS(2004) II-2/9.4.2.1
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 28 September 2024
Resolved
FOR TANKERS OF 20,000 TONNES DEADWEIGHT AND UPWARDS, THE PROTECTION OF THE CARGO TANKS SHALL BE ACHIEVED BY A FIXED INERT GAS SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE FIRE SAFETY CODE.
THE INERT GAS SYSTEM REFERRED TO IN CHAPTER 11-2 OF CONVENTION SHALL BE DESIGNED, CONSTRUCTED, AND TESTED TO THE SATISFACTION OF THE ADMINISTRATION.
PSCO OBSERVED WATER BACKFEEDING INTO 1G BLOWER #1 LEAKING OUT OF THE BLOWER CASING. ADDITIONALLY, PSCO OBSERVED TEMPORY REPAIR ON SCRUBBER THAT WAS ACTIVELY LEAKING.
74 SOLAS (2004) II-2/5.5.1.1
2007 FSS 15.2.2.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2024
Resolved
MAIN AND AUXILLARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL.
PSCO FOUND MAIN ENGINE TO BE PARTIALLY REPAIRED BY KONGSBERG TECHNICIAN. MAIN ENGINE UNABLE TO BE CONTROLLED FROM BRIDGE CONTROL STATION. PERMANENT REPAIRS TO BE COMPLETED BY 10DEC2024.
74 SOLAS (04) II-1/31.1
Code : 705C
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 May 2024
Resolved
The inert gas system shall be capable of inerting, purging and gas-freeing empty tanks and maintaining the atmosphere in cargo tanks with the required oxygen content. The inert gas system is not able to produce inert gas and has an inoperable gas temperature sensor.
74 SOLAS 20 II-2/4.5.5.3.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 16 May 2024
Resolved
Ships shall be designed, constructed and maintained with mechanical requirements of a classification society which is recognized by the administration. In the cargo pump room, the stripping pup is leaking cargo from a seal around the drive shaft and has acc accumulated cargo on the deck below the stripping pump.
74 SOLAS 04 II-1/3-1
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 March 2023
Resolved
The IG System shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks. Vessel IG System not functioning properly. Unable to prove performance test in presence of [name withheld] restricted. Submit class report to CG to clear deficiency.
SOLAS II-2/4.5.5.3.2 FSS Code 15.2.2.1.2.5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 March 2023
Resolved
In tankers, electrical wiring, equipment, cables shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. exlosion proof lighting found broken and exposed in cargo room.
SOLAS II-1 / 45.11
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 March 2023
Resolved
A main electrical lighting system shall provide illumination to pars of the ship normally used by crew. Two overhead lights found inoperable in AB seamen staterooms.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 1 September 2022
Resolved
Subject to the provisions of paragraph 4 and 5 of regulation 3 of this Annex. Oil tankers of 150 gross tonnage and above shall be equipped with an oil discharge monitoring and control system approved by the administration. PSCO observed "sheen" coming from vessel near ODME discharge port. Crew suspected faulty valve in ODME system piping causing pollution from vessel. Request repairs be made and class verify proper opreation of all manual and automatic valves, check for proper operation and structural integrity of entire ODME system and components. Marpol (17) Annex I/31.1 60ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 April 2022
Resolved
For tankers of 20,000 tonnes deadweight and upwards constructed on or after 1 July 2002 but before 1 January 2016, the protection of the cargo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code. Inert gas system includes inert gas systems using flue gas, inert gas generators, and nitrogen generators and means the inert gas plant and inert gas distribution together with means for preventing backflow of cargo gases to machinery spaces, fixed and portable measuring instruments and control devices. The vessel'sinert gas system was unable to calibrate to the level of oxygen required. 74 SOLAS (20) II-2/4.5.5.1 & FSS Code 15.2.1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2022
Resolved
Main propulsion machinery and all auxilliary machinery essentialto the propulsion and safety of the ship shall, as fitted in the ship, be designed to operate. Main engine cylinder #5 exhaust valve air cylinder actuator non-return valve was inoperable. 74 SOLAS (04) II-1/26.6
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 November 2018
Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT UNLESS SUCH EQUIPMENT IS APPROPRIATELY CERTIFIED FOR SAFE USAGE IN VAPOURS LIKELY TO BE ENCOUNTERED. BALLAST PUMP TEMPERATURE SENSOR HOUSING DETERIORATED AND CRACKED EXPOSING LIVE WIRES IN VESSELS CARGO PUMP ROOM.
74 SOLAS (04) II-1/45.10.4
Lifesaving › Launching Appliances › Winch Brake
Issued 7 June 2016
Resolved
0635: Before a ship leaves port and at all times during the voyage all lifesaving appliances shall be working and ready for immediate use. Rescue boat davit not raising as designed. Crew must apply pressure to brake in order to raise. Boat aft limit switch fell off during operations, Electrician replaced, 74 SOLAS (14), III/20.2, 60ac.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 7 June 2016
Resolved
1835: Tank vessels 20,000 deadweight tons and above shall have IGS in accordance with FSS Code. System not performing as designed. IGG/IGS shut down during operation; crew cannot deduce why and attempted to troubleshoot for 1 hour with no success. #1 blower spraying water. Electrician tampering with setting no valves, 74 SOLAS (140 II-2/4.5.5.1.1, 60ac.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 June 2016
Resolved
2050: Machinery, Boilers and other pressure vessels; associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Patches found on S/W cooling line to atmosphere pump, flange leaking by sounding pipe for sludge tank, leakage on harbor cool S/W vacuum pump at flange, 74 SOLAS (14) II-1/26, 17ac.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 7 June 2016
Resolved
2510: Vessel must maintain ballast water management plan that has been developed specifically for the vessel and is understood by those who follow it. Not all items have been addressed and crew is not properly filling out Bio-Fouling / Ballast Water forms, 33CFR151.2050(g), 40ac.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 June 2016
Resolved
2050: Means shall be provided to control leakage of flammable material. All generators have oil leakage that drips to the deck below and platform in front of emergency escape, posing a slipping / safety hazard, 74 SOLAS(14), II-2/4.1.1, 40ac.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 7 June 2016
Resolved
2510: Marine sanitation device must be operated and maintained in accordance with the manufacturers instructions, patch found on #3 cleaning line, 33CFR159.121(b), 40ac.
Documentation › Logs/Records › Oil Record Book
Issued 7 June 2016
Resolved
1710: The Oil Record Book part 1 shall be completed on each occasion on a tank to tank basis. Weekly soundings for Dirty Lube Oil Tank were logged with incorrect capacity based off outdated IOPP form B from 2012. Incorrect entry dates back to May 2015, logging the capacity as 5.17 instead of 5.7, MARPOL Annex 1 /17.2, 10c.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 15 May 2014
Resolved
1850; Fire protection cargo deck area - Each Inert Gas System must be designed, constructed and installed in accordance with the provisions of SOLAS II-2/62. IGG Blower #1 drain is patched, There is a leak on the boiler line to the scrubber and a pin hole leak on Scrubber high level alarm, 46CFR32.53-10 (40ac).
Engineering › Pressure Vessel › Piping
Issued 15 May 2014
Resolved
1400; The machinery, boilers, other pressure vessels and associated piping and fittings shall be of a design and constructed for the service for which they are intended. Incinerator door found bent, Emergency Generator fuel line flange leakage, Pump room air line stbd side, patched, central cooler #2 Temp/pressure gauges patched, and F/W valve for tank cleaning patched, SOLAS II-1/26 (40ac).
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 15 May 2014
Resolved
2510- Sewage must be maintained and operated in accordance with manufacturer's instructions. Vessel does not have chlorine kit and crew is not following section 5.2 for proper maintenance, 33CFR159.7 (10c).
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 15 May 2014
Resolved
2510; Oil transfer procedures must meet the Code of Federal Regulations. Gave [name withheld] sample copy, 33CFR155.750 (10c).
Operations/Management › Ballast Water Managment › Sediments
Issued 15 May 2014
Resolved
2510; Vessel must maintain a Ballast Water Management Plan that has been developed for the vessel. Crew has not been using Handling log for to record sediment. Procedures are not in place for disposal of item from sea strainer as per Bio fouling (MGPS). 33CFR151.2050(g) (10c).
Operations/Management › Pollution › Control of Garbage
Issued 15 May 2014
Resolved
2120; Ships Garbage Management Plan is incomplete. Orange cans for collection of batteries are not identified. Mixed garbage was found in various containers mixed food, paper, plastic and wood items were found at the final collection point prior to disposal into the seas. PSC personnel believe mixed items along with food waste have been thrown overboard, MARPOL Annex V/10.