HALCYON

HALCYON is a freight ship. The Coast Guard has recorded 10 inspections since 2008, most recently in September 2011, along with 29 deficiencies — 1 with no resolution recorded — and 4 operational controls, 1 with no removal date recorded.

Records from 2008 to 2011. Most recent: operational control imposed, 3 September 2011.

Built
Not recorded
Last inspected
3 September 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9200031 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B4185
935253
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-935253

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 3 calendar years (2008–2011)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7970 - Convention (Subpart B), Gross Ton
3513 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

3 September 2011 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4134566
22 November 2010 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3893270
13 October 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3343766
2 October 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3337429
24 September 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3331965
19 August 2008 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3303463
23 July 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3276560
9 July 2008 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3262343
12 June 2008 ISPS II Exam · PII Safety Exam · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3234639
18 February 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3137640

Deficiency record · 29

Construction/Loadline › Structures › Scupper
Issued 9 July 2008 Resolved
Emergency generators ventilation scuppers are severly wasted. Vessel to repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 13 October 2008
Resolution: Received Class report from ABS satisfying requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 July 2008 Resolved
02 Firedoors in the engine room were found to not latch properly. Vessel to repair fire doors to the satisfaction of the Coast Gaurd.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2008
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 9 July 2008 Resolved
While inspecting the nautical charts it was noted that the vessel only had up to week 22 notice to mariners, which means that the vessel is 6 weeks behind in there updates. Vessel to correct this prior to departure.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 9 July 2008
Resolution: Vessel got copy of updates to there charts up to week 25.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 July 2008 Resolved
Vessel does not have transfer procedures posted at transfer points. Vessel must post transfer procedures at transfer points.
Action required: 705 - Other - as specified
Due 9 August 2008
Resolved 13 October 2008
Resolution: Cleared by [name withheld]3 Schneider
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 9 July 2008 Resolved
Vessel could not provide transfer procedures in a reasonable amount of time.
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 9 July 2008
Resolution: Corrected on the spot.
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 9 July 2008 Resolved
Vessel's transfer procedures are not in compliance with U.S. Reg's. Vessel to rewrite and change so that the transfer procedures are incompliance with U.S. Regulations.
Action required: 705 - Other - as specified
Due 9 August 2008
Resolved 13 October 2008
Resolution: Cleared by [name withheld]3 Schneider
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 June 2008 Resolved
Company and vessel have demonstrated a failure to effectively implement its safety management system due to the following items: See scanned form B in document section of MISLE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 26 June 2008
Resolution: ISM Audit was conducted. see scanned report.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 June 2008 Resolved
Engine room bilges were observed to be completely covered with oil from the deck plates down into the lowest point in the bilges, including all piping and associated equipment posing a significant fire hazard. There is a significant amount of standing oily water in the bilges.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 26 June 2008
Resolution: Bilges and E/R were cleaned to satisfaction.
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 June 2008 Resolved
When tested, vessels secondary radar did not operate. Repair to satisfaction of class prior to departure.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 26 June 2008
Resolution: Repairs were made to satisfaction of class & CG.
Navigation › Collision/Grounding Avoidance › Transponder
Issued 12 June 2008 Resolved
When tested, vessel’s speed log did not operate. Digital display does not accurately show the vessel’s speed compared to the GPS as per conversation with the 2nd Mate. Vessel has received Dispensation letter from the Republic of the Marshall Islands for conducting repairs until dry dock April 2010. See letter under Doc/Certs
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 30 April 2010
Resolution: Received technical report from agent (see documents)
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 June 2008 Resolved
While conducting engine room inspection, observed planks sitting on upper walkway leading to the air intake pipes on the main engine. Chief engineer stated that planks were used to physically access top of engine. Planks posed serious risk of injury due to absence of proper installation of railings and guards.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 26 June 2008
Resolution: Cleaned up to the satisfaction of class.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 June 2008 Resolved
Bare/exposed wires were observed on the overhead directly above the shaft in the engine room creating a fire hazard. Exposed wires were also observed while conducting deck walk on the 6th deck on the overhead of the topside ladderwell.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 26 June 2008
Resolution: Repairs were made to the satisfaction of class.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 June 2008 Resolved
While conducting engine room inspection observed cans of paint stored in the emergency escape access space. In addition, multiple cans of paint were stored throughout the engine room.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 26 June 2008
Resolution: Cleaned up and addressed by class.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 12 June 2008 Resolved
During inspection of freefall lifeboat, only 30L of fresh/drinking water was onboard. Lifeboat is required to carry 60L of water as required by capacity. Corrected on the spot.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2008
Resolved 14 June 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 June 2008 Resolved
A-30 fire door was found to be tied off to main deck handrail. This door shall not be fitted with hold-backs of any type. Corrected on the spot.
Action required: 705 - Other - as specified
Due 12 June 2008
Resolved 12 June 2008
Resolution: Corrected on the spot.
Engineering › Freshwater Generation System › Distiller Chamber
Issued 12 June 2008 Resolved
Vessels fresh water hydrophone system #1 pump was inoperable. Systems #2 pump shaft seal was observed to have an excessive leak. Both pumps are to be repaired and tested to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 26 June 2008
Resolution: Both pumps have been repaired and tested to the satisfaction of class.
Construction/Loadline › Penetrations › Valve Flange
Issued 12 June 2008 Resolved
While conducting engine room inspection, observed blanked off discharge valves in lower level of engine room, port side, without any associated piping. Class to attest to the necessity of overboard discharge valves prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Class has addressed overboard discharge valves prior to departure.
Communications › Alarms/Indicators › General Alarm
Issued 12 June 2008 Resolved
General alarm on Captains deck outside of captains cabin was missing and inoperable. Replace/repair to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 26 June 2008
Resolution: Replaced and repaired to the satisfaction of class.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 June 2008 Resolved
Three (3) of five (5) life ring lights were observed to not light and are inoperable. Repair to the satisfaction of class
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 June 2008
Resolved 26 June 2008
Resolution: Repair have been made to the satisfaction of class
Construction/Loadline › Penetrations › Valve Flange
Issued 12 June 2008 Resolved
Upon boarding vessel it was found that the controllable pitch propeller vent check valve at the starboard side bunker station was completely wasted and detached from the pipe. Class is to attest to the proper repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Class has attested to the proper repairs prior to departure.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2008 Resolved
Auxiliary sea water cooling piping line at manifold portside lower level aft was found leaking and patched. Repairs to be completed to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 26 June 2008
Resolution: Repaired to the satisfaction of class.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 June 2008 Resolved
While conducting deck walk it was found that the starboard side handrail adjacent to cargo hold #1 was wasted and broken. Repair to satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Repaired to satisfaction of class.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 12 June 2008 Resolved
While conducting engine room inspection, observed inoperable lighting in the emergency escape scuttle. Vessel needs to replace lighting fixtures to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 26 June 2008
Resolution: Vessel replaced lighting fixtures to the satisfaction of class.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2008 Resolved
While conducting engine room inspection, observed a blank flange on the salt water cooling overboard discharge, portside, for the auxiliary generator. Class is to attest to the proper repairs prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Class attested to the proper repairs prior to departure.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 12 June 2008 Resolved
While conducting engine room exam it was found that two fire extinguishers were missing according to the Fire Control Plan. Class to attest to proper firefighting arrangement in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Class attested to all proper firefighting arrangement in engine room.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 12 June 2008 Resolved
While conducting deck walk the forward liferaft was found to be stored in the bosun hold due to insufficient tie-downs. Repair to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Repair were made to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 June 2008 Resolved
The marine sanitation device that was approved as a Type II system by the Administration had no chemicals to comminute and disinfect the sewage in the tank. The chief engineer insisted that they are retaining all sewage on board. Vessel needs to order chemicals so that the sewage treatment plan is in compliance.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2008
Resolution: Received proper chemicals.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 12 June 2008 Resolved
Garbage receptacles were not stored on poop-deck as per garbage management plan. Class to attest to proper arrangement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2008
Resolved 26 June 2008
Resolution: Garbage receptacles were stored on poop-deck as per garbage management plan.
Fire Fighting › Nozzles › Condition
Issued 12 June 2008 No resolution recorded
During the deckwalk it was determined that two fire stations were missing spanner wrenches. Spanner wrenches are to be replaced and attested to by class.
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2008 — due date passed with no resolution recorded
Resolution: Spanner wrenches are replaced and attested to by class.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.